The Application of Negative Atrioventricular Hysteresis in Cardiac Resynchronization Therapy With MultiPoint Pacing
Study Overview
Status
Status
Conditions
Conditions
Intervention / Treatment
Intervention / Treatment
Study Type
Study Type
Enrollment (Actual)
Enrollment
Phase
Phase
- Not Applicable
Contacts and Locations
Study Locations
-
-
MI
-
San Donato Milanese, MI, Italy, 20097
- I.R.C.C.S. Policlinico San Donato
-
-
Participation Criteria
Eligibility Criteria
Eligibility Criteria
Ages Eligible for Study
Accepts Healthy Volunteers
Sampling Method
Study Population
Description
Inclusion Criteria:
- Scheduled for implantation of an MPP-enabled SJM Quadripolar CRT Pacing System
- QRS duration > 140 ms
- Left bundle branch block documented
- Ability to provide informed consent for study participation
- Willing to comply with the study evaluation requirements
- At least 18 years of age
Exclusion Criteria:
- Resting ventricular rate >100 bpm
- Intrinsic PR interval > 300 ms
- Paroxysmal or persistent atrial tachycardia or atrial fibrillation documented
- A recent myocardial infarction, ablation, drug intoxication, electrolyte imbalance, or any condition within the last 90 days that would be contraindicated for CRT programming changes in the opinion of the investigator
- Women who are pregnant or who plan to become pregnant during the study
Study Plan
How is the study designed?
Design Details
Number of groups / cohorts
Cohorts and Interventions
Group / CohortGroup / Cohort |
Intervention / TreatmentIntervention / Treatment |
|---|---|
|
CRT+NAVH
Surface ECG and pressure-volume loop recordings will be taken during the adjustment of programmable Cardiac Resynchronization Therapy and Negative Atrioventricular Hysteresis settings at the device implant procedure
|
Cardiac Resynchronization Therapy with Negative Atrioventricular Hysteresis
|
What is the study measuring?
Primary Outcome Measures
Primary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Acute change in QRS duration due to CRT with NAVH, relative to intrinsic conduction
Time Frame: 1 day
|
Acute changes in surface ECG QRS duration resulting from Cardiac Resynchronization Therapy (CRT) with Negative Atrioventricular Hysteresis (NAVH) over a range of programmable values
|
1 day
|
Secondary Outcome Measures
Secondary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Acute changes in LV pressure-volume hemodynamics due to CRT with NAVH, relative to intrinsic conduction
Time Frame: 1 day
|
Acute changes in left ventricular pressure-volume hemodynamics resulting from Cardiac Resynchronization Therapy with Negative Atrioventricular Hysteresis over a range of programmable values
|
1 day
|
|
Change in QRS duration after one day of CRT with NAVH, relative to intrinsic conduction
Time Frame: 1 day
|
Changes in surface ECG QRS duration after one day of Cardiac Resynchronization Therapy with Negative Atrioventricular Hysteresis
|
1 day
|
Collaborators and Investigators
Sponsor
Sponsor
Study record dates
Study Major Dates
Study Start (Actual)
Study Start
Primary Completion (Actual)
Primary Completion
Study Completion (Actual)
Study Completion
Study Registration Dates
First Submitted
First Submitted
First Submitted That Met QC Criteria
First Submitted That Met QC Criteria
First Posted (Estimated)
First Posted
Study Record Updates
Last Update Posted (Actual)
Last Update Posted
Last Update Submitted That Met QC Criteria
Last Update Submitted That Met QC Criteria
Last Verified
Last Verified
More Information
Terms related to this study
Additional Relevant MeSH Terms
Other Study ID Numbers
Other Study ID Numbers
- CRD_856
Drug and device information, study documents
Studies a U.S. FDA-regulated drug product
Studies a U.S. FDA-regulated device product
This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.