Catheter Ablation of Longstanding Persistent Atrial Fibrillation
Optimal Ablation Endpoint for Longstanding Persistent Atrial Fibrillation: a Randomized Prospective Study
Study Overview
Status
Status
Conditions
Conditions
Intervention / Treatment
Intervention / Treatment
Detailed Description
Study Type
Study Type
Enrollment (Anticipated)
Enrollment
Phase
Phase
- Not Applicable
Contacts and Locations
Study Contact
Study Contact
- Name: Yuanlong Mr Wang, MD
- Phone Number: 08615800719348
- Email: sdzhilong2011@163.com
Study Locations
-
-
Shanghai
-
Shanghai, Shanghai, China, 200030
- Recruiting
- Shanghai Chest Hospital
-
Contact:
- Xu Liu, MD
- Phone Number: 08613017321303
- Email: xkliuxuchest@163.com
-
-
Participation Criteria
Eligibility Criteria
Eligibility Criteria
Ages Eligible for Study
Accepts Healthy Volunteers
Genders Eligible for Study
Description
Inclusion Criteria:
- Patients with longstanding persistent atrial fibrillation (lasting for>1 year)
- Exhibited refractoriness to at least one antiarrhythmic drug
- Left atrial diameter <=60mm
Exclusion Criteria:
- Patients with uncontrolled congestive heart failure
- Having significant valvular disease and/or prosthetic heart valve(s)
- With myocardial infarction or stroke within 6 months of screening
- With Significant congenital heart disease;ejection fraction was <40% measured by echocardiography
- Allergic to contrast media
- Contraindication to warfarin or heparin
- Severe pulmonary disease e.g. restrictive pulmonary disease
- Chronic obstructive disease (COPD)
- Left atrial (LA) thrombus measured by pre-procedure transesophageal echocardiography
- Having any contraindication to right or left sided heart catheterization
- Poor general health
- Life expectancy less than 6 months
Study Plan
How is the study designed?
Design Details
- Primary Purpose: Treatment
- Allocation: Randomized
- Interventional Model: Parallel Assignment
- Masking: Single
Number of Arms
Arms and Interventions
Participant Group / ArmParticipant Group / Arm |
Intervention / TreatmentIntervention / Treatment |
|---|---|
|
Active Comparator: PVI+LA linear ablation +CFAE ablation
The ablation procedure for atrial fibrillation guided by CARTO system, including PVI, LA linear ablation (roof line and mitral isthmus)and CFAE ablation.
|
PVI was the complete isolation of all PVs, which was confirmed by entrance and/or exit block into or from the PV antra.
LA linear ablation include mitral isthmus ablation and roof line ablation.
Mitral isthmus ablation (from the mitral annulus to the left inferior PV) was performed first, followed by roof line ablation (between the right and left superior PVs).
Ablation catheter was maintained in a stable position when the electrograms were being recorded for at least 5 s to avoid artifacts.The procedural endpoint of CFAEs was the complete elimination of fragmented atrial activity in local electrograms.
3 dimensional mapping system
|
|
Active Comparator: PVI+linear ablation +CFAE ablation
The ablation procedure for atrial fibrillation guided by CARTO system, including PVI,roof line and mitral isthmus,cavotricuspid isthmus abaltion and CFAE ablation.
|
PVI was the complete isolation of all PVs, which was confirmed by entrance and/or exit block into or from the PV antra.
LA linear ablation include mitral isthmus ablation and roof line ablation.
Mitral isthmus ablation (from the mitral annulus to the left inferior PV) was performed first, followed by roof line ablation (between the right and left superior PVs).
Ablation catheter was maintained in a stable position when the electrograms were being recorded for at least 5 s to avoid artifacts.The procedural endpoint of CFAEs was the complete elimination of fragmented atrial activity in local electrograms.
3 dimensional mapping system
Right atrial CTI ablation was performed during SR.
|
|
Active Comparator: PVI+CFAE ablation
The ablation procedure for atrial fibrillation guided by CARTO system, including PVI and CFAE ablation.
|
PVI was the complete isolation of all PVs, which was confirmed by entrance and/or exit block into or from the PV antra.
Ablation catheter was maintained in a stable position when the electrograms were being recorded for at least 5 s to avoid artifacts.The procedural endpoint of CFAEs was the complete elimination of fragmented atrial activity in local electrograms.
3 dimensional mapping system
|
What is the study measuring?
Primary Outcome Measures
Primary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Time to first documented recurrence of atrial arrhythmias
Time Frame: 2-year follow-up
|
Time to first documented recurrence of atrial arrhythmias after the first ablation procedure and after the final ablation procedure
|
2-year follow-up
|
Secondary Outcome Measures
Secondary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Procedure duration at ablation
Time Frame: At the end of the first ablation procedure
|
Minutes elapsed from the first puncture of the femoral vein to the removal of the last catheter
|
At the end of the first ablation procedure
|
|
Ablation time at ablation
Time Frame: At the end of the first ablation procedure ]
|
Minutes elapsed from the onset of the first energy delivery to the end of the last energy delivery
|
At the end of the first ablation procedure ]
|
|
Fluoroscopy time at ablation
Time Frame: At the end of the first ablation procedure
|
Minutes of fluoroscopy used during the entire ablation procedure
|
At the end of the first ablation procedure
|
|
Complications
Time Frame: 2-year follow-up
|
Incidence of peri-procedural complications including stroke, PV stenosis, cardiac perforation, esophageal injury, and death.
|
2-year follow-up
|
|
Type of recurrent arrhythmia
Time Frame: 2-year follow-up
|
Specific type of recurrent atrial arrhythmia
|
2-year follow-up
|
|
Number of redo procedures
Time Frame: 2-year follow-up
|
Number of redo procedures,including two or more procedures
|
2-year follow-up
|
Collaborators and Investigators
Sponsor
Sponsor
Investigators
Investigators
- Principal Investigator: Xu Mr Liu, MD, Shanghai Chest Hospital
Study record dates
Study Major Dates
Study Start
Study Start
Primary Completion (Anticipated)
Primary Completion
Study Completion (Anticipated)
Study Completion
Study Registration Dates
First Submitted
First Submitted
First Submitted That Met QC Criteria
First Submitted That Met QC Criteria
First Posted (Estimate)
First Posted
Study Record Updates
Last Update Posted (Estimate)
Last Update Posted
Last Update Submitted That Met QC Criteria
Last Update Submitted That Met QC Criteria
Last Verified
Last Verified
More Information
Terms related to this study
Keywords
Additional Relevant MeSH Terms
Other Study ID Numbers
Other Study ID Numbers
- DSL-20161002
Plan for Individual participant data (IPD)
Plan to Share Individual Participant Data (IPD)?
This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.