Effect of Three Side Hole Infusion Catheter on CT Image Quality Compared to a Standard Infusion Catheter
IV Contrast Administration: Effect of Three Side Hole Infusion Catheter on CT Image Quality, Infusion Pressure, and Infusion Rates, Compared to a Standard Infusion Catheter
Study Overview
Status
Status
Conditions
Conditions
Intervention / Treatment
Intervention / Treatment
Detailed Description
Study Type
Study Type
Enrollment (Actual)
Enrollment
Phase
Phase
- Not Applicable
Contacts and Locations
Study Locations
-
-
Texas
-
Houston, Texas, United States, 77030
- The University of Texas Health Science Center at Houston
-
-
Participation Criteria
Eligibility Criteria
Eligibility Criteria
Ages Eligible for Study
Accepts Healthy Volunteers
Genders Eligible for Study
Description
Inclusion Criteria:
- Patients undergoing contrast enhanced CT abdomen pelvis examinations at Lyndon B. Johnson General Hospital in Texas
- Patients whose access point is the antecubital fossa
- Patients receiving 20 or 22 gauge catheters for their CT exam
- Patients scanned on two 64 slice CT scanners at the same hospital
Exclusion Criteria:
- patients whose access point is other than antecubital fossa
Study Plan
How is the study designed?
Design Details
- Primary Purpose: Diagnostic
- Allocation: Randomized
- Interventional Model: Parallel Assignment
- Masking: Triple
Number of Arms
Arms and Interventions
Participant Group / ArmParticipant Group / Arm |
Intervention / TreatmentIntervention / Treatment |
|---|---|
|
Experimental: Becton Dickinson Nexiva Diffusics System
Intervention with the new Becton Dickinson Nexiva Diffusics System will be evaluated to see if it will improve image quality compared to the standard catheter.
|
Becton Dickinson Nexiva Diffusics System will be used to inject IV contrast and will be compared to a single hole catheter to see if it improves image quality in the main vessels in the abdomen and pelvis because of its novel design.
|
|
Active Comparator: Standard intravenous catheter
Standard catheter with one hole at the tip will be compared to novel 3 hole Becton Dickinson Nexiva Diffusics System to see which catheter provides the best image quality.
|
Standard catheter with one hole at the tip will be compared to a novel 3 hole catheter to see which catheter provides the best image quality.
|
What is the study measuring?
Primary Outcome Measures
Primary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Image Quality as Assessed by Ratio of Tissue Density of Main Portal Vein (MPV) to the Aorta
Time Frame: at the time of CT scanning
|
The ratio of tissue density measured in the main portal vein (MPV) to tissue density in the aorta on the CT images will be determined and will provide a measure of biodistribution, which is an important indicator of image quality.
Dividing each Hounsfield unit measurement by the aorta density and determining these ratios will be done on a per patient basis to assess biodistribution as a measure of image quality.
|
at the time of CT scanning
|
|
Image Quality as Assessed by Ratio of Tissue Density of Spleen to the Aorta
Time Frame: at the time of CT scanning
|
The ratio of tissue density measured in the spleen to tissue density in the aorta on the CT images will be determined and will provide a measure of biodistribution, which is an important indicator of image quality.
Dividing each Hounsfield unit measurement by the aorta density and determining these ratios will be done on a per patient basis to assess biodistribution as a measure of image quality.
|
at the time of CT scanning
|
|
Image Quality as Assessed by Ratio of Tissue Density of Inferior Vena Cava (IVC) to the Aorta
Time Frame: at the time of CT scanning
|
The ratio of tissue density measured in the inferior vena cava (IVC) to tissue density in the aorta on the CT images will be determined and will provide a measure of biodistribution, which is an important indicator of image quality.
Dividing each Hounsfield unit measurement by the aorta density and determining these ratios will be done on a per patient basis to assess biodistribution as a measure of image quality.
|
at the time of CT scanning
|
|
Image Quality as Assessed by Rating Scale
Time Frame: at the time of CT scanning
|
Radiologists blinded to catheter type will review images and rate them on a scale of 1 to 10. 10 indicates a better outcome.
|
at the time of CT scanning
|
Secondary Outcome Measures
Secondary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Peak Contrast Infusion Pressure
Time Frame: at the time of CT scanning
|
The peak contrast infusion pressure is recorded in the electronic health record (EHR) during every CT examination preformed at the hospitals taking part in this study.
|
at the time of CT scanning
|
|
Injection Flow Rate
Time Frame: at the time of CT scanning
|
The injection flow rate is recorded in the electronic health record (EHR) during every CT examination preformed at the hospitals taking part in this study.
|
at the time of CT scanning
|
Collaborators and Investigators
Sponsor
Sponsor
Investigators
Investigators
- Principal Investigator: Joseph Hasapes, MD, The University of Texas Health Science Center, Houston
Study record dates
Study Major Dates
Study Start (Actual)
Study Start
Primary Completion (Actual)
Primary Completion
Study Completion (Actual)
Study Completion
Study Registration Dates
First Submitted
First Submitted
First Submitted That Met QC Criteria
First Submitted That Met QC Criteria
First Posted (Estimate)
First Posted
Study Record Updates
Last Update Posted (Actual)
Last Update Posted
Last Update Submitted That Met QC Criteria
Last Update Submitted That Met QC Criteria
Last Verified
Last Verified
More Information
Terms related to this study
Other Study ID Numbers
Other Study ID Numbers
- HSC-MS15-0906
This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.