Posterior Ligament Complex Assessment Without Magnetic Resonance Image in Thoracolumbar Fractures (PAM)
Posterior Ligament Complex Assessment Without Magnetic Resonance Image in Thoracolumbar Fractures (T11-L2): A Diagnostic Test Study to Analyze Sensitivity and Specificity
Study Overview
Status
Status
Conditions
Conditions
Intervention / Treatment
Intervention / Treatment
Detailed Description
Study Type
Study Type
Enrollment (Actual)
Enrollment
Contacts and Locations
Study Locations
-
-
-
Hangzhou, China, 310003
- The 1st Affiliated Hospital of Zhejiang University
-
-
-
-
-
Assiut, Egypt, 71526
- Assiut Universtiy Hospitals
-
-
-
-
-
Coimbatore, India, 641 011
- Ganga Hospital
-
-
-
-
-
Uijeongbu-si, Korea, Republic of, 118765
- Uijeongbu St. Mary's Hospital
-
-
-
-
-
Belfast, United Kingdom, BT12 6BA
- Royal Victoria Hospital
-
-
Participation Criteria
Eligibility Criteria
Eligibility Criteria
Ages Eligible for Study
Accepts Healthy Volunteers
Genders Eligible for Study
Sampling Method
Study Population
Description
Inclusion Criteria:
- Age 18 to 60 years
- A3/A4 TL fracture between T11-L2 with or without PLC injury
- Pre-treatment CT scan and MRI. Radiographs (if available)
- Signed Informed consent, if required by EC/IRB
Exclusion Criteria:
- Pathological fractures
- Multilevel contiguous and non-contiguous injuries
- Fractures with obvious spinous process split indicating tension band failure such as AO type B1 injuries
- Fractures with translation injuries or dislocations such as AO type C injuries
Study Plan
How is the study designed?
Design Details
- Observational Models: Cohort
- Time Perspectives: Retrospective
Number of groups / cohorts
Cohorts and Interventions
Group / CohortGroup / Cohort |
Intervention / TreatmentIntervention / Treatment |
|---|---|
|
Cases
Retrospective radiological evaluation in cases presenting A3 or A4 TL burst fractures (AOSpine classification) between T11 to L2 with or without suspected PLC injury
|
Radiological evaluation will be performed in already existing imaging exams.
Superior-inferior end plate angle (SIEA), vertebral body height (BH), local kyphosis (LK), inter-spinous distance (ISD) and inter-pedicular distance (IPD) will be measured in CT scans and radiographs (if available).
PLC injury will be determinated with the gold standard method (MRI).
|
What is the study measuring?
Primary Outcome Measures
Primary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Sensitivity of Local kyphosis (LK) and/or Inter-spinous distanceI (SD)
Time Frame: CT scans, MRI and x-rays were taken on admission into hospital after the patient got a thoracolumbar fracture. These images will be retrospectively analyzed (eligible images are from the date of the fracture up to 3 days after the event).
|
Sensitivity of LK and/or ISD Is defined as the proportion of patients with PLC injury correctly diagnosed by an increase in LK and/or ISD difference compared to MRI.
The Specificity si defined as the proportion of patients with PLC injury correctly diagnosed by an increase in LK and/or ISD difference compared to MRI.
The gold standard is a diagnostic test and it is the best accepted test that is assumed to be able to determine the true disease state.
It is considered as the reference method or the best test available.
|
CT scans, MRI and x-rays were taken on admission into hospital after the patient got a thoracolumbar fracture. These images will be retrospectively analyzed (eligible images are from the date of the fracture up to 3 days after the event).
|
Secondary Outcome Measures
Secondary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Sensitivity and specificity of superior-inferior end plate angle (SIEA)
Time Frame: CT scans, MRI and x-rays were taken on admission into hospital after the patient got a thoracolumbar fracture. These images will be retrospectively analyzed (eligible images are from the date of the fracture up to 3 days after the event).
|
Is defined as the proportion of patients with PLC injury correctly diagnosed by a increase in SIEA compared to MRI.
|
CT scans, MRI and x-rays were taken on admission into hospital after the patient got a thoracolumbar fracture. These images will be retrospectively analyzed (eligible images are from the date of the fracture up to 3 days after the event).
|
|
Sensitivity and specificity of vertebral body height (BH)
Time Frame: CT scans, MRI and x-rays were taken on admission into hospital after the patient got a thoracolumbar fracture. These images will be retrospectively analyzed (eligible images are from the date of the fracture up to 3 days after the event).
|
Is defined as the proportion of patients with PLC injury correctly diagnosed by an decrease in BH compared to MRI.
|
CT scans, MRI and x-rays were taken on admission into hospital after the patient got a thoracolumbar fracture. These images will be retrospectively analyzed (eligible images are from the date of the fracture up to 3 days after the event).
|
|
Sensitivity and specificity of inter-pedicular distance (IPD)
Time Frame: CT scans, MRI and x-rays were taken on admission into hospital after the patient got a thoracolumbar fracture. These images will be retrospectively analyzed (eligible images are from the date of the fracture up to 3 days after the event).
|
Is defined as the proportion of patients with PLC injury correctly diagnosed by a increase in IPD compared to MRI.
|
CT scans, MRI and x-rays were taken on admission into hospital after the patient got a thoracolumbar fracture. These images will be retrospectively analyzed (eligible images are from the date of the fracture up to 3 days after the event).
|
Other Outcome Measures
Other Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Accuracy of CT scan measurements
Time Frame: CT scans, MRI and x-rays were taken on admission into hospital after the patient got a thoracolumbar fracture. These images will be retrospectively analyzed (eligible images are from the date of the fracture up to 3 days after the event).
|
Accuracy describes how closely the measured value is to the true value and is an indicator of systematic errors.
The accuracy of measurements of each CT scan parameter will be compared between the participating sites.
|
CT scans, MRI and x-rays were taken on admission into hospital after the patient got a thoracolumbar fracture. These images will be retrospectively analyzed (eligible images are from the date of the fracture up to 3 days after the event).
|
|
Inter-rater reliability
Time Frame: CT scans, MRI and x-rays were taken on admission into hospital after the patient got a thoracolumbar fracture. These images will be retrospectively analyzed (eligible images are from the date of the fracture up to 3 days after the event).
|
The inter-rater reliability is defined as the percent agreement between the measurements of the different parameters by the different observers.
The CT scans and radiographs (if available) distributed to the participating sites will be measured at each site by all participating MDs within each team or at least by one trained PI.
|
CT scans, MRI and x-rays were taken on admission into hospital after the patient got a thoracolumbar fracture. These images will be retrospectively analyzed (eligible images are from the date of the fracture up to 3 days after the event).
|
Collaborators and Investigators
Sponsor
Sponsor
Investigators
Investigators
- Principal Investigator: Shanmuganathan Rajasekaran, Prof. MD, Ganga Hospital
- Study Chair: Test Testing, MD, TESTING
Study record dates
Study Major Dates
Study Start (Actual)
Study Start
Primary Completion (Actual)
Primary Completion
Study Completion (Actual)
Study Completion
Study Registration Dates
First Submitted
First Submitted
First Submitted That Met QC Criteria
First Submitted That Met QC Criteria
First Posted (Estimate)
First Posted
Study Record Updates
Last Update Posted (Actual)
Last Update Posted
Last Update Submitted That Met QC Criteria
Last Update Submitted That Met QC Criteria
Last Verified
Last Verified
More Information
Terms related to this study
Additional Relevant MeSH Terms
Other Study ID Numbers
Other Study ID Numbers
- AOCID_PAM
Plan for Individual participant data (IPD)
Plan to Share Individual Participant Data (IPD)?
IPD Plan Description
Drug and device information, study documents
Studies a U.S. FDA-regulated drug product
Studies a U.S. FDA-regulated device product
This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.