Protamine Sulfate During Transcatheter Aortic Valve Implantation (PS TAVI)
Use of Protamine Sulfate During Transcatheter Aortic Valve Implantation - Impact on Bleeding and Thromboembolic Complications
Study Overview
Status
Status
Conditions
Conditions
Intervention / Treatment
Intervention / Treatment
Detailed Description
Study Type
Study Type
Enrollment (Actual)
Enrollment
Phase
Phase
- Phase 4
Contacts and Locations
Study Locations
-
-
-
Warsaw, Poland
- First Department of Cardiology, Medical University of Warsaw
-
-
Participation Criteria
Eligibility Criteria
Eligibility Criteria
Ages Eligible for Study
Accepts Healthy Volunteers
Genders Eligible for Study
Description
Inclusion Criteria:
- patients who underwent successful TAVI
- with any approved TAVI device
- via transfemoral access
- with use of any of the approved vascular closure devices
- provided written informed consent
Exclusion Criteria:
- no consent
- periprocedural complications requiring continuation of heparin or administration of protamine sulfate
- alergy to fish, protamine, protamine derivates, history of Humulin N, Novolin N, Novolin NPH, Gensulin N, SciLin N, NPH Iletin II and isophane insulin intake
Study Plan
How is the study designed?
Design Details
- Primary Purpose: PREVENTION
- Allocation: RANDOMIZED
- Interventional Model: PARALLEL
- Masking: SINGLE
Number of Arms
Arms and Interventions
Participant Group / ArmParticipant Group / Arm |
Intervention / TreatmentIntervention / Treatment |
|---|---|
|
ACTIVE_COMPARATOR: Protamine sulfate
After obtaining optimal valve deployment patients will receive protamine sulfate (1 mg for each 100 units of UFH i.v.).
Measurement of activated clotting time (ACT) will be performed (after heparin administration and after protamine sulfate administration).
|
|
|
PLACEBO_COMPARATOR: 0.9% NaCl
After obtaining optimal valve deployment patients will receive 0.9% saline (20 ml i.v.).
Measurement of activated clotting time (ACT) will be performed (after heparin administration and after placebo administration).
|
What is the study measuring?
Primary Outcome Measures
Primary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Bleeding complications
Time Frame: 48 hours or hospital discharge, whichever occurs first
|
Composite of life-threatening and major bleeding complications according to Valve Academic Research Consortium (VARC) criteria (unit of measure: 0/1 [absence/presence])
|
48 hours or hospital discharge, whichever occurs first
|
Secondary Outcome Measures
Secondary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Successful closure of the access-site
Time Frame: 15 minutes
|
Angiographic assessment of contrast extravasation from the access site after closure with preclose device at the end of the procedure.
Unit of measure: 0/1 (absence/presence).
|
15 minutes
|
|
Thromboembolic complications
Time Frame: 5 days or hospital discharge, whichever occurs first
|
Clinical assessment of thromboembolic complications in the central nervous system and peripheral vasculature (e.g.
mesenteric, extremities).
Unit of measure: 0/1 (absence/presence)
|
5 days or hospital discharge, whichever occurs first
|
|
Assessment of peri-procedural myocardial muscle injury
Time Frame: 24 hours
|
Measurements of levels of high sensitivity cardiac troponin T and isoenzyme MB of creatine kinase before the procedure and 6- and 12-24 hours after the procedure.
Unit of measure: high sensitivity cardiac troponin T [ng/L], isoenzyme MB of creatine kinase [mcg/L].
|
24 hours
|
|
All-cause mortality
Time Frame: 30 days
|
All-cause mortality.
Unit of measure: 0/1 (absence/presence).
|
30 days
|
Collaborators and Investigators
Sponsor
Sponsor
Publications and helpful links
General Publications
- Kappetein AP, Head SJ, Genereux P, Piazza N, van Mieghem NM, Blackstone EH, Brott TG, Cohen DJ, Cutlip DE, van Es GA, Hahn RT, Kirtane AJ, Krucoff MW, Kodali S, Mack MJ, Mehran R, Rodes-Cabau J, Vranckx P, Webb JG, Windecker S, Serruys PW, Leon MB. Updated standardized endpoint definitions for transcatheter aortic valve implantation: the Valve Academic Research Consortium-2 consensus document. Eur Heart J. 2012 Oct;33(19):2403-18. doi: 10.1093/eurheartj/ehs255.
- Holmes DR Jr, Mack MJ, Kaul S, Agnihotri A, Alexander KP, Bailey SR, Calhoon JH, Carabello BA, Desai MY, Edwards FH, Francis GS, Gardner TJ, Kappetein AP, Linderbaum JA, Mukherjee C, Mukherjee D, Otto CM, Ruiz CE, Sacco RL, Smith D, Thomas JD, Harrington RA, Bhatt DL, Ferrari VA, Fisher JD, Garcia MJ, Gardner TJ, Gentile F, Gilson MF, Hernandez AF, Jacobs AK, Kaul S, Linderbaum JA, Moliterno DJ, Weitz HH; American Heart Association; American Society of Echocardiography; European Association for Cardio-Thoracic Surgery; Heart Failure Society of America; Mended Hearts; Society of Cardiovascular Anesthesiologists; Society of Cardiovascular Computed Tomography; Society for Cardiovascular Magnetic Resonance. 2012 ACCF/AATS/SCAI/STS expert consensus document on transcatheter aortic valve replacement: developed in collabration with the American Heart Association, American Society of Echocardiography, European Association for Cardio-Thoracic Surgery, Heart Failure Society of America, Mended Hearts, Society of Cardiovascular Anesthesiologists, Society of Cardiovascular Computed Tomography, and Society for Cardiovascular Magnetic Resonance. J Thorac Cardiovasc Surg. 2012 Sep;144(3):e29-84. doi: 10.1016/j.jtcvs.2012.03.001. No abstract available.
- Rodes-Cabau J, Dauerman HL, Cohen MG, Mehran R, Small EM, Smyth SS, Costa MA, Mega JL, O'Donoghue ML, Ohman EM, Becker RC. Antithrombotic treatment in transcatheter aortic valve implantation: insights for cerebrovascular and bleeding events. J Am Coll Cardiol. 2013 Dec 24;62(25):2349-2359. doi: 10.1016/j.jacc.2013.03.029. Epub 2013 Apr 10.
- Linke A, Wenaweser P, Gerckens U, Tamburino C, Bosmans J, Bleiziffer S, Blackman D, Schafer U, Muller R, Sievert H, Sondergaard L, Klugmann S, Hoffmann R, Tchetche D, Colombo A, Legrand VM, Bedogni F, lePrince P, Schuler G, Mazzitelli D, Eftychiou C, Frerker C, Boekstegers P, Windecker S, Mohr FW, Woitek F, Lange R, Bauernschmitt R, Brecker S; ADVANCE study Investigators. Treatment of aortic stenosis with a self-expanding transcatheter valve: the International Multi-centre ADVANCE Study. Eur Heart J. 2014 Oct 7;35(38):2672-84. doi: 10.1093/eurheartj/ehu162. Epub 2014 Mar 28.
- Borz B, Durand E, Godin M, Tron C, Canville A, Litzler PY, Bessou JP, Cribier A, Eltchaninoff H. Incidence, predictors and impact of bleeding after transcatheter aortic valve implantation using the balloon-expandable Edwards prosthesis. Heart. 2013 Jun;99(12):860-5. doi: 10.1136/heartjnl-2012-303095. Epub 2012 Dec 12.
- Gauthier C, Astarci P, Baele P, Matta A, Kahn D, Kefer J, Momeni M. Mid-term survival after transcatheter aortic valve implantation: Results with respect to the anesthetic management and to the access route (transfemoral versus transapical). Ann Card Anaesth. 2015 Jul-Sep;18(3):343-51. doi: 10.4103/0971-9784.159804.
- Zbronski K, Grodecki K, Gozdowska R, Ostrowska E, Wysinska J, Rymuza B, Scislo P, Wilimski R, Kochman J, Filipiak KJ, Opolski G, Huczek Z. Protamine sulfate during transcatheter aortic valve implantation (PS TAVI) - a single-center, single-blind, randomized placebo-controlled trial. Kardiol Pol. 2021;79(9):995-1002. doi: 10.33963/KP.a2021.0070. Epub 2021 Jul 22.
Study record dates
Study Major Dates
Study Start
Study Start
Primary Completion (ACTUAL)
Primary Completion
Study Completion (ACTUAL)
Study Completion
Study Registration Dates
First Submitted
First Submitted
First Submitted That Met QC Criteria
First Submitted That Met QC Criteria
First Posted (ESTIMATE)
First Posted
Study Record Updates
Last Update Posted (ACTUAL)
Last Update Posted
Last Update Submitted That Met QC Criteria
Last Update Submitted That Met QC Criteria
Last Verified
Last Verified
More Information
Terms related to this study
Additional Relevant MeSH Terms
Other Study ID Numbers
Other Study ID Numbers
- WUM-KZ
This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.