The Efficiency of Colon Capsule Endoscopy in Colon Cancer Screening
The Comparison of the Efficiency of Colon Capsule Endoscopy and Optical Colonoscopy in Patients With Positive Immunochemical Fecal Occult Blood Test
Study Overview
Status
Status
Conditions
Conditions
Intervention / Treatment
Intervention / Treatment
Detailed Description
Multicentre, multidisciplinary (3 gastroenterology units; biostatistics department; cooperation with general practitioners), prospective study is focused on examination of individuals with average colorectal cancer (CRC) risk (asymptomatic, age 50-75 years).
In years 2017 - 2019, there will be 230 persons with positive semi-quantitative immunochemical fecal occult blood tests (FIT; QuikRead, Orion Diagnostica Oy, Finland) with cut-off level 75 ng/ml involved. Every person will be examined by second generation colon capsule endoscopy (CCE2) and optical colonoscopy afterwards.
Main objective is to show that the negative predictive value (NPV) of the CCE2 applied in patients with positive FIT results is sufficient to include this method in the National CRC screening as filter test with aim to reduce the necessity of subsequent optical colonoscopy.
Study Type
Study Type
Enrollment (Anticipated)
Enrollment
Phase
Phase
- Not Applicable
Contacts and Locations
Study Contact
Study Contact
- Name: Michal Voska
- Phone Number: 00420 773200360
- Email: michal.voska@uvn.cz
Study Locations
-
-
-
Prague, Czechia
- Recruiting
- Military University Hospital
-
-
Participation Criteria
Eligibility Criteria
Eligibility Criteria
Ages Eligible for Study
Accepts Healthy Volunteers
Genders Eligible for Study
Description
Inclusion Criteria:
- age 50 - 75 years
- asymptomatic (no enterorhagy, weight loss or anemia)
- signed informed consent with the study and with colonoscopy
Exclusion Criteria:
CRC high-risk group patients
- having first degree relatives diagnosed with colorectal cancer at age ˂ 60 years
- FAP, HNPCC and other hereditary CRC syndromes probands
- positive personal medical history of colorectal neoplasia (advanced adenomatous polyp, colorectal cancer)
- recent diagnostic, follow-up or preventive colonoscopy in ≤ 3 years (FOBT-positive colonoscopy, screening colonoscopy)
- colonoscopy contraindication
- severe acute inflammatory bowel disease
- severe comorbidities; likely non-compliance of the patient
- no informed consent signed (with the study and/or with colonoscopy)
Study Plan
How is the study designed?
Design Details
- Primary Purpose: SCREENING
- Allocation: NA
- Interventional Model: SINGLE_GROUP
- Masking: NONE
Number of Arms
Arms and Interventions
Participant Group / ArmParticipant Group / Arm |
Intervention / TreatmentIntervention / Treatment |
|---|---|
|
EXPERIMENTAL: Pillcam® COLON 2 Capsule and colonoscopy
Persons with positive immunochemical fecal occult blood tests will be examined by second generation colon capsule endoscopy (CCE2) and optical colonoscopy afterwards.
|
The second generation of PillCam colon capsule endoscopy (CCE-2) is 11.6 mm × 31.5 mm in size and has two imagers, that each have a 172° angle of view, allowing for almost 360° visual coverage of the colon.
CCE-2 has an adaptive frame rate from 4 to 35 images per second.
This means that the camera is able to capture up to 35 pictures while in motion whereas 4 images per second are captured when it is virtually stationary.
During the examination the patient wears a sensor array which is attached to the abdomen and a data recorder for storage of the information generated by the ingested capsule.
After the examination the data are downloaded into the workstation and a video is generated.
Optical colonoscopy is the standard method for evaluating the colon
|
What is the study measuring?
Primary Outcome Measures
Primary Outcome Measures
Outcome Measure |
Time Frame |
|---|---|
|
Negative predictive value (NPV) of the CCE2 for large polyps (≥ 10 mm)
Time Frame: 1 day
|
1 day
|
Secondary Outcome Measures
Secondary Outcome Measures
Outcome Measure |
Time Frame |
|---|---|
|
CCE2 accuracy for detection of advanced adenomas
Time Frame: 1 day
|
1 day
|
|
CCE2 accuracy for detection of colon cancer
Time Frame: 1 day
|
1 day
|
|
CCE2 and optical colonoscopy acceptance (special questionnaire)
Time Frame: 1 day
|
1 day
|
|
Cost-effectiveness analyses: cost reduction of preventive colonoscopies spared
Time Frame: 1 day
|
1 day
|
Collaborators and Investigators
Sponsor
Sponsor
Collaborators
Collaborators
Investigators
Investigators
- Study Director: Stepan Suchanek, Military University Hospital, Prague
Study record dates
Study Major Dates
Study Start (ACTUAL)
Study Start
Primary Completion (ANTICIPATED)
Primary Completion
Study Completion (ANTICIPATED)
Study Completion
Study Registration Dates
First Submitted
First Submitted
First Submitted That Met QC Criteria
First Submitted That Met QC Criteria
First Posted (ACTUAL)
First Posted
Study Record Updates
Last Update Posted (ACTUAL)
Last Update Posted
Last Update Submitted That Met QC Criteria
Last Update Submitted That Met QC Criteria
Last Verified
Last Verified
More Information
Terms related to this study
Additional Relevant MeSH Terms
Other Study ID Numbers
Other Study ID Numbers
- 16-29614A
Plan for Individual participant data (IPD)
Plan to Share Individual Participant Data (IPD)?
Drug and device information, study documents
Studies a U.S. FDA-regulated drug product
Studies a U.S. FDA-regulated device product
product manufactured in and exported from the U.S.
This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.