Molecular Breast Imaging in Screening Breast Cancer
Study Overview
Status
Status
Conditions
Conditions
Intervention / Treatment
Intervention / Treatment
Detailed Description
Keywords: molecular breast imaging, MBI, breast cancer, mammography, sonography
- Background: In breast cancer screening, the sensitivity of mammography is about 71-96 %, but the sensitivity decreases in the three following groups: (1) under 50 years old; (2) dense breast parenchyma; (3) higher risk of breast cancer. The Health and Welfare Ministry data in recent 2 years showed Taiwanese women accepted mammography for screening in the ratio of only about 36%, representing many missed opportunities for early detection. One reason to reject mammography may be the discomfort caused by compression. To solve the above mammography possible weakness, other screening methods came into being, such as molecular breast imaging (MBI) of nuclear medicine. Radiotracer of Tc-99m sestamibi was found for targeting breast tumor 20 years ago, and approved by the FDA in 1997. However, the application is limited due to the suboptimal scanning camera design. Ten years later, the Mayo Clinics developed MBI technology, using small-sized semiconductor detectors. Then it become possible that the nuclear technologist have patient's breast tissue fit the detector in almost the same fashion of mammography without heavy compression.
- Objective: The aim of this study is to evaluate the recall rate and diagnostic accuracy of MBI, mammography and breast echo, for female population.
- Study design: Female patients referred to Nuclear Medicine Department for myocardial perfusion scan will be recruited in this study. It is because that MBI and myocardial perfusion scan share the same radiotracer. Then MBI will become additional scanning only. About 1800 female subjects will involve, and further mammography and/or breast sonography will be arranged within 6 months after MBI. Participants will be encouraged to receive mammography every 2 years and telephone survey. We hope that this study will help us to compare and evaluate the recall rate/diagnostic efficiency of MBI, mammography and breast sonography, and to determine best ways of breast cancer screening.
Study Type
Study Type
Enrollment (Actual)
Enrollment
Phase
Phase
- Not Applicable
Contacts and Locations
Study Locations
-
-
-
Keelung, Taiwan, 204
- TzuPei Su
-
-
Participation Criteria
Eligibility Criteria
Eligibility Criteria
Ages Eligible for Study
Accepts Healthy Volunteers
Genders Eligible for Study
Description
Inclusion Criteria:
- Female patients undergoing myocardial perfusion imaging will be eligible if they sign the informed consent.
Exclusion Criteria:
- They are unable to understand and sign the consent form
- They are physically unable to sit upright and still for 20 minutes.
- They have undergone breast surgery or breast biopsy within the last 12 months.
- They have had trauma to the breast tissue or undergone radiation treatment to the breast within the last 12 months.
Study Plan
How is the study designed?
Design Details
- Primary Purpose: Screening
- Allocation: N/A
- Interventional Model: Single Group Assignment
- Masking: None (Open Label)
Number of Arms
Arms and Interventions
Participant Group / ArmParticipant Group / Arm |
Intervention / TreatmentIntervention / Treatment |
|---|---|
|
Other: Three breast screening modalities
Subjects who have had mammography less than two years ago will receive MBI and breast ultrasound only.
Other participants will receive three interventions including molecular breast imaging, mammography and breast ultrasound.
The interval between each examination will be less than 6 months.
|
Molecular breast imaging will be performed at 5-10 minutes after intravenous injection of 15-20 millicurie (mCi) Tc-99m sestamibi.
Both craniocaudal (CC) view and mediolateral oblique (MLO) images of the breast are taken.
Other Names:
During the procedure, the breast is compressed using a dedicated mammography unit.
Parallel-plate compression evens out the thickness of breast tissue to increase image quality by reducing the thickness of tissue that x-rays must penetrate, decreasing the amount of scattered radiation, reducing the required radiation dose, and holding the breast still (preventing motion blur).
Both craniocaudal (CC) view and mediolateral oblique (MLO) images of the breast are taken.
Other Names:
Ultrasound investigation of breast is performed by members of breast cancer team.
If abnormality is found by the procedure, biopsy will not be performed directly.
Other Names:
|
What is the study measuring?
Primary Outcome Measures
Primary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Recall rate
Time Frame: 6 months
|
The frequency with which a radiologist or physician interprets findings of an examination as positive
|
6 months
|
Secondary Outcome Measures
Secondary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Diagnostic efficacy
Time Frame: 6 months
|
The sensitivity, specificity, positive predictive value and negative predictive value of each imaging modality
|
6 months
|
Collaborators and Investigators
Sponsor
Sponsor
Study record dates
Study Major Dates
Study Start (Actual)
Study Start
Primary Completion (Actual)
Primary Completion
Study Completion (Actual)
Study Completion
Study Registration Dates
First Submitted
First Submitted
First Submitted That Met QC Criteria
First Submitted That Met QC Criteria
First Posted (Actual)
First Posted
Study Record Updates
Last Update Posted (Actual)
Last Update Posted
Last Update Submitted That Met QC Criteria
Last Update Submitted That Met QC Criteria
Last Verified
Last Verified
More Information
Terms related to this study
Keywords
Additional Relevant MeSH Terms
Other Study ID Numbers
Other Study ID Numbers
- CMRPG2E0341
Plan for Individual participant data (IPD)
Plan to Share Individual Participant Data (IPD)?
Drug and device information, study documents
Studies a U.S. FDA-regulated drug product
Studies a U.S. FDA-regulated device product
This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.