3D-Printed Personalized Metal Implant in Surgical Treatment of Ankle Bone Defects
Study Overview
Status
Status
Conditions
Conditions
Intervention / Treatment
Intervention / Treatment
Detailed Description
Bone defects are common in ankle disease, and the conventional treatment includes autologous or allogeneic bone grafts. However, autologous bone graft may cause complications and its source is rather limited; allogeneic bone graft may cause disease transmission and the mechanical strength of the graft is low after processing.
The 3D printing technology has provided a new way of solving this problem. It has the following technical advantages: wide range of graft sources, high mechanical strength, and can be prepared in advance according to various shapes.
Preparation procedure: first, establish the individualized ankle model according to the patient's ankle CT scan data and then prepare the implant model; second, conduct surgery rehearsal and place the implant model in the ankle model for observation; third, after confirmation, use titanium alloy in the 3D printing machine to prepare the individualized metal implant, which is in line with the Chinese National Standard "Wrought titanium and titanium alloy for surgical implants" (GB/T 13810-2007); fourth, implant the individualized metal implant into the bone defect area after sterilization.
Study Type
Study Type
Enrollment (Anticipated)
Enrollment
Phase
Phase
- Not Applicable
Contacts and Locations
Study Contact
Study Contact
- Name: Xiaojun Duan, MD
- Phone Number: 86-23-68765290
- Email: duanxiaojun@hotmail.com
Study Locations
-
-
Chongqing
-
Chongqing, Chongqing, China, 400030
- Recruiting
- Southwest Hospital
-
Contact:
- Xiaojun Duan, MD
- Phone Number: 86-23-68765290
- Email: duanxiaojun@hotmail.com
-
-
Participation Criteria
Eligibility Criteria
Eligibility Criteria
Ages Eligible for Study
Accepts Healthy Volunteers
Genders Eligible for Study
Description
Inclusion Criteria:
- Receive ankle or subtalar arthrodesis;
- Refuse to use autologous bone graft or allogeneic bone graft.
Exclusion Criteria:
- The local defect area is small;
- Refuse to use permanent metal metal implant.
Study Plan
How is the study designed?
Design Details
- Primary Purpose: Treatment
- Allocation: N/A
- Interventional Model: Single Group Assignment
- Masking: None (Open Label)
Number of Arms
Arms and Interventions
Participant Group / ArmParticipant Group / Arm |
Intervention / TreatmentIntervention / Treatment |
|---|---|
|
Experimental: 3D-printed personalized metal implant
3D-printed personalized metal implant will be used in bone defect surgeries.
|
3d-printed personalized metal implant will be used in subtalar arthrodesis.
|
What is the study measuring?
Primary Outcome Measures
Primary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Visual Analogue Scale (VAS)
Time Frame: Postoperative 24 months
|
The decrease in VAS score from baseline
|
Postoperative 24 months
|
Secondary Outcome Measures
Secondary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
American Orthopedic Foot and Ankle Society (AOFAS) Ankle-Hindfoot Scale
Time Frame: Postoperative 24 months
|
The increase in AOFAS score from baseline
|
Postoperative 24 months
|
|
Lower limb alignment
Time Frame: Postoperative 24 months
|
Analyze the lower limb alignment by radiography
|
Postoperative 24 months
|
|
Osteotylus growth
Time Frame: Postoperative 24 months
|
Analyze the osteotylus growth by radiography
|
Postoperative 24 months
|
|
Implant displacement
Time Frame: Postoperative 24 months
|
Assess the implant displacement by radiography
|
Postoperative 24 months
|
Collaborators and Investigators
Sponsor
Sponsor
Investigators
Investigators
- Principal Investigator: Xiaojun Duan, MD, Southwest Hospital, China
Study record dates
Study Major Dates
Study Start (Actual)
Study Start
Primary Completion (Anticipated)
Primary Completion
Study Completion (Anticipated)
Study Completion
Study Registration Dates
First Submitted
First Submitted
First Submitted That Met QC Criteria
First Submitted That Met QC Criteria
First Posted (Actual)
First Posted
Study Record Updates
Last Update Posted (Actual)
Last Update Posted
Last Update Submitted That Met QC Criteria
Last Update Submitted That Met QC Criteria
Last Verified
Last Verified
More Information
Terms related to this study
Additional Relevant MeSH Terms
Other Study ID Numbers
Other Study ID Numbers
- 3DIMPLANT
Plan for Individual participant data (IPD)
Plan to Share Individual Participant Data (IPD)?
Drug and device information, study documents
Studies a U.S. FDA-regulated drug product
Studies a U.S. FDA-regulated device product
This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.
Clinical Trials on Bone Diseases
-
NCT07379008CompletedBone Diseases | Bone Cysts | Bone Neoplasm | Enchondromatosis | Bone Defects
-
NCT06853392CompletedBone Loss | Bone Resorption | Bone Remodeling Disorder
-
NCT04789759UnknownBone Loss | Alveolar Bone Resorption
-
NCT01922804Unknown
-
NCT07540156Not yet recruiting
-
NCT05732558CompletedBone Infection | Bone Tumor | Bone Lesion
-
NCT02367846Active, not recruitingOther Disorders of Bone Development and Growth
-
NCT04803500CompletedBone Regeneration | Alveolar Bone Resorption | Immediate Implant Placement
-
NCT02617901CompletedBone Diseases, Developmental
-
NCT04998058Not yet recruitingAlveolar Bone Loss | Bone Loss, Alveolar | Grafting Bone | Alveolar Bone Atrophy | Bone Loss, Osteoclastic
Clinical Trials on 3d-printed personalized metal implant
-
NCT06310070RecruitingOstomy | Leakage | 3D Printing
-
NCT03941028UnknownLarge Segmental Bone Defect
-
NCT07538869Completed
-
NCT06851897Active, not recruiting
-
NCT07440186Not yet recruiting
-
NCT04000672CompletedRandomized Controlled Trial | Osteotomy
-
NCT06819995RecruitingDental Implant | Guided Surgery Accuracy
-
NCT05396222Not yet recruiting