Up to now, no studies are available where a comparison has been made between the accuracy of, on the one hand, the gold standard PSG and, on the other hand, a home monitoring sleep apnea-diagnostic system, consisting of a pulse oximeter, and accelerometer, a smartphone for snoring analysis, and a mattress for ballistocardiographic (BCG) recordings.
The purpose of this study is twofold. On the one hand, a comparison between the predictive performance of an automated home monitoring system and the gold standard PSG in sleep apnea diagnosis will be performed. The home monitoring system consists of a pulse oximeter, an accelerometer, a smartphone to record ambient sound, and a mattress to record the BCG signal. This system will be provided by KU Leuven and Equilli, two partners that work together with the Sleep Laboratory at UZ Leuven and the group STADIUS of the KU Leuven in the OSA+ project. The system performs automated signal processing and classification in order to determine the presence of sleep apnea events. On the other hand, this study aims to improve the phenotyping of patients suffering from sleep apnea. This task will be first developed using the classical PSG and later an evaluation will be performed on the less obtrusive system.
Study Overview
Status
Status
Conditions
Conditions
Intervention / Treatment
Intervention / Treatment
Study Type
Study Type
Phase
Phase
- Not Applicable
Contacts and Locations
Study Locations
-
-
-
Leuven, Belgium, 3000
- University Hospitals Leuven
-
-
Participation Criteria
Eligibility Criteria
Eligibility Criteria
Ages Eligible for Study
Accepts Healthy Volunteers
Description
Inclusion Criteria:
- Patients referred to the sleep lab for a diagnostic polysomnography because of suspicion of sleep apnea will be considered to participate in the trial upon signature of the informed consent.
Exclusion Criteria:
- Patients younger than 18 years
Study Plan
How is the study designed?
Design Details
- Primary Purpose: Diagnostic
- Allocation: N/A
- Interventional Model: Single Group Assignment
- Masking: None (Open Label)
Number of Arms
Arms and Interventions
Participant Group / ArmParticipant Group / Arm |
Intervention / TreatmentIntervention / Treatment |
|---|---|
|
Experimental: OSA Homemonitoring
Homemonitoring diagnostic system
|
In addition to the standard full-night diagnostic polysomnography, patients will be evaluated during the same night with a "homemonitoring diagnostic system" that consists out of a pulse oximeter, accelerometer, smartphone for audio recording and a mattress that measures the ballistocardiogram.
|
What is the study measuring?
Primary Outcome Measures
Primary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Diagnostic accuracy of the homemonitoring system
Time Frame: 1 day
|
Accuracy of the homemonitoring system of apnea/hypopnea index measurement (in comparison with gold standard) polysomnography)
|
1 day
|
Secondary Outcome Measures
Secondary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Cardiovascular risk prediction tool
Time Frame: 1 day
|
The homemonitoring system will lead to new signals that could better predict cardiovascular risk in comparison with the apnea/hypopnea index of the polysomnography.
This tool will be based on a new algorithm that will be developed based on the results.
|
1 day
|
|
Apnea/hypopnea index severity
Time Frame: 1 day
|
Evaluation of agreement between patient categorisation into apnea severity categories obtained by the homemonitoring system and the diagnostic polysomnography scoring
|
1 day
|
Collaborators and Investigators
Sponsor
Sponsor
Investigators
Investigators
- Principal Investigator: Bertien Buyse, MD, PhD, UZ Leuven
Study record dates
Study Major Dates
Study Start (Actual)
Study Start
Primary Completion (Actual)
Primary Completion
Study Completion (Actual)
Study Completion
Study Registration Dates
First Submitted
First Submitted
First Submitted That Met QC Criteria
First Submitted That Met QC Criteria
First Posted (Actual)
First Posted
Study Record Updates
Last Update Posted (Actual)
Last Update Posted
Last Update Submitted That Met QC Criteria
Last Update Submitted That Met QC Criteria
Last Verified
Last Verified
More Information
Terms related to this study
Additional Relevant MeSH Terms
Other Study ID Numbers
Other Study ID Numbers
- S60319
Plan for Individual participant data (IPD)
Plan to Share Individual Participant Data (IPD)?
Drug and device information, study documents
Studies a U.S. FDA-regulated drug product
Studies a U.S. FDA-regulated device product
product manufactured in and exported from the U.S.
This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.
Clinical Trials on Obstructive Sleep Apnea
-
NCT07399782Not yet recruitingSleep Apnea/Hypopnea Syndrome | Sleep Apnea Syndrome, Obstructive | Sleep Apnea Syndrome (OSAS) | Sleep Apnea - Obstructive
-
NCT07186725RecruitingObstructive Sleep Apnea (SAOS) | Obstructive Sleep Apnea (OSAS)
-
NCT07301762Enrolling by invitationObstructive Sleep Apnea | OSA | Obstructive Sleep Apnea (OSA)
-
NCT07465874Not yet recruitingObstructive Sleep Apnea | Sleep Apnea
-
NCT07332442RecruitingObstructive Sleep Apnea | Sleep Apnea
-
NCT07545421Not yet recruitingObstructive Sleep Apnea
-
NCT07337239Not yet recruiting
-
NCT07331285Not yet recruitingObstructive Sleep Apnea
-
NCT07303452RecruitingObstructive Sleep Apnea
Clinical Trials on Homemonitoring diagnostic system
-
NCT04416776UnknownStrabismus | Ophthalmological Disorder
-
NCT03499145CompletedArtificial Intelligence | Ophthalmopathy
-
NCT06828068CompletedSpinal Diseases | Bone Diseases | Scoliosis | Spinal Curvatures | Musculoskeletal Disease
-
NCT07156591Not yet recruiting
-
NCT07590063Not yet recruiting