Cardiac, Pulmonary and Diaphragm Sonography for the Early Diagnosis of the Different Etiologies Underlying Failure of Weaning From Mechanical Ventilation (WEAN US)
Combined Cardiac, Pulmonary and Diaphragm Sonography for the Evaluation of Failure in Ventilation Weaning
Weaning patients off ventilation in an ICU is sometimes difficult, because of three major inter-related etiologies: impaired lung, heart and diaphragm function. In this context, ultrasonography during tests to wean patients off ventilation could make it possible to diagnose cardiac dysfunction, a loss of pulmonary aeration or diaphragm dysfunction and thus reduce the number of failures at extubation.
The study will be carried out in 100 patients on mechanical ventilation following abdominal or heart surgery, who will have echocardiography, and pulmonary and diaphragm ultrasonography.
Study Overview
Status
Status
Conditions
Conditions
Study Type
Study Type
Enrollment (Anticipated)
Enrollment
Contacts and Locations
Study Contact
Study Contact
- Name: Belaïd BOUHEMAD
- Phone Number: +33 03.80.29.93.42
- Email: belaid.bouhemad@chu-dijon.fr
Study Locations
-
-
-
Dijon, France, 21079
- Recruiting
- Chu Dijon Bourgogne
-
Contact:
- Belaïd BOUHEMAD
- Phone Number: +33 03 80 29 93 42
- Email: belaid.bouhemad@chu-dijon.fr
-
-
Participation Criteria
Eligibility Criteria
Eligibility Criteria
Ages Eligible for Study
Accepts Healthy Volunteers
Genders Eligible for Study
Sampling Method
Study Population
Description
Inclusion Criteria:
- Patients on mechanical ventilation for at least 48 hours
- Age ≥ 60 years
- Patients who have undergone abdominal or heart surgery
Exclusion Criteria:
- Patients with a known neuromuscular disease
- Patients younger than 60 years
- Duration of mechanical ventilation <48h
- Non-surgical patients
- Patients with severe COPD
Study Plan
How is the study designed?
Design Details
What is the study measuring?
Primary Outcome Measures
Primary Outcome Measures
Outcome Measure |
Time Frame |
|---|---|
|
Echocardiography
Time Frame: At baseline
|
At baseline
|
|
Lung ultrasonography
Time Frame: At baseline
|
At baseline
|
|
Diaphragm ultrasonography
Time Frame: At baseline
|
At baseline
|
Collaborators and Investigators
Sponsor
Sponsor
Publications and helpful links
Study record dates
Study Major Dates
Study Start (Actual)
Study Start
Primary Completion (Anticipated)
Primary Completion
Study Completion (Anticipated)
Study Completion
Study Registration Dates
First Submitted
First Submitted
First Submitted That Met QC Criteria
First Submitted That Met QC Criteria
First Posted (Actual)
First Posted
Study Record Updates
Last Update Posted (Actual)
Last Update Posted
Last Update Submitted That Met QC Criteria
Last Update Submitted That Met QC Criteria
Last Verified
Last Verified
More Information
Terms related to this study
Other Study ID Numbers
Other Study ID Numbers
- KLEIN 2016
Drug and device information, study documents
Studies a U.S. FDA-regulated drug product
Studies a U.S. FDA-regulated device product
This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.
Clinical Trials on Mechanical Ventilation
-
NCT02927613CompletedProlonged Mechanical Ventilation | Home Mechanical Ventilation
-
NCT07083128CompletedWeaning Failure | Weaning From Mechanical Ventilation | Mechanical Ventilation
-
NCT04193254CompletedMechanical Ventilation Complication | Mechanical Power | Driving Pressure | Lung Protective Ventilation
-
NCT00502489UnknownMechanical Ventilation | Weaning | Prolonged Ventilation
-
NCT04827927CompletedMechanical Ventilation | Mechanical Power
-
NCT07337408Not yet recruitingWeaning Failure | Weaning From Mechanical Ventilation | Weaning From Mechanical Ventilation, Extubation
-
NCT07518498Not yet recruitingHypnosis | Weaning Mechanical Ventilation | Hypnosis During Weaning From Invasive Mechanical Ventilation
-
NCT06450678RecruitingMechanical Ventilation | Mechanical Ventilator Weaning
-
NCT04249414SuspendedMechanical Ventilation | Ventilation Perfusion Mismatch