A Study Raindrop Near Vision Inlay in Presbyopes Implanted in Corneal Pockets
A Prospective Study to Evaluate the Raindrop Near Vision Inlay in Presbyopes Implanted in Corneal Pockets With a Delayed or Non-Delayed Approach
Study Overview
Status
Status
Conditions
Conditions
Intervention / Treatment
Intervention / Treatment
Detailed Description
Study Type
Study Type
Enrollment (Actual)
Enrollment
Phase
Phase
- Not Applicable
Contacts and Locations
Study Locations
-
-
Florida
-
Panama City, Florida, United States, 32409
- Eye Center of North Florida
-
-
Participation Criteria
Eligibility Criteria
Eligibility Criteria
Ages Eligible for Study
Accepts Healthy Volunteers
Genders Eligible for Study
Description
1.1 Inclusion Criteria:
1.1.1 Patients require a near reading add from +1.5 to +2.5 D in the non-dominant eye.
1.1.2 Patients have a photopic pupil size of at least 3.0 mm in the non-dominant eye.
1.1.3 Patients have a central corneal thickness ≥ 500 microns in the non-dominant eye.
1.1.4 Patients have corrected distance and near visual acuity of 20/25 or better in each eye.
1.1.5 Patients have uncorrected near acuity of 20/40 or worse in the non-dominant eye.
1.1.6 Patients are willing and able to understand and sign a written Informed Consent Form prior to any study-specific procedures.
1.1.7 Patients are willing and able to return for scheduled follow-up examinations for 24 months after corneal inlay implantation.
1.1 Exclusion Criteria:
1.1.1 Patients with clinically significant dry eye (i.e., significant diffuse punctate staining with fluorescein and a tear breakup time less than 8 s) in either eye.
1.1.2 Patients with a planned corneal residual bed thickness that is less than 300 microns (corneal thickness - (intended ablation depth + intended flap thickness)).
1.1.3 Patients with macular pathology based on dilated fundus exam and/or optical coherence tomography (OCT) image.
1.1.4 Patients who would be co-managed by an ophthalmologist or optometrist who is not approved as a ReVision Optics investigator.
1.1.5 Patients with ocular pathology or disease (including pupil pathology such as fixated pupils) that might confound the outcome or increase the risk of adverse event.
1.1.6 Patients taking systemic or topical medications that might confound the outcome or increase the risk of adverse event. Patients taking isotretinoin or amiodarone hydrochloride and any other medication that affects the tear film or accommodation, including but not limited to, mydriatic, cycloplegic and mitotic agents, tricyclic, phenothiazines, benzodiazepines, and first generation antihistamines.
1.1.7 Patients with known sensitivity to any planned study medications. 1.1.8 Patients with residual, recurrent, active or uncontrolled eyelid disease. 1.1.9 Patients with significant corneal asymmetry or irregular topography. 1.1.10 Patients with clinically significant anterior segment pathology. 1.1.11 Patients with any corneal abnormality, including but not limited to, slit lamp findings for corneal staining Grade 3 or higher, recurrent corneal erosion or severe basement membrane disease, and pterygium extending onto the cornea.
1.1.12 Patients with ophthalmoscopic/topographic signs of keratoconus or those who are keratoconus suspect.
1.1.13 Patients with history of Herpes zoster or Herpes simplex keratitis. 1.1.14 Patients with any progressive retinal disease or patients with a history or evidence of retinal vascular occlusion and/or hypercoagulability, because of the risks associated with high pressures during suction application.
1.1.15 Patients with known history of steroid-responsive intraocular pressure increases, glaucoma, preoperative IOP > 21 mm Hg, or are otherwise suspected of having glaucoma.
1.1.16 Patients with amblyopia or strabismus or those who are at risk for developing strabismus postoperatively as determined by corneal light reflex and cover-uncover testing.
1.1.17 Patients with diabetic retinopathy, collagen, vascular, diagnosed autoimmune disease (e.g., lupus, rheumatoid arthritis, fibromylagia), immunodeficiency (e.g., HIV), connective tissue disease, or clinically significant atopic syndrome such as allergies or asthma.
1.1.18 Patients on chronic systemic corticosteroid or other immunosuppressive therapy that may affect wound healing.
1.1.19 Patients with any type of active cancer (ophthalmic or non-ophthalmic). 1.1.20 Patients with uncontrolled infections of any kind. 1.1.21 Patients who are pregnant, lactating, of child-bearing potential and not practicing a medically approved method of birth control, or planning to become pregnant during the course of the trial, and patients with other conditions associated with fluctuation of hormones that could lead to refractive changes.
1.1.22 Patients who actively participate in contact sports (i.e., boxing, martial arts) where impacts to the face and eye are a normal occurrence.
1.1.23 Patients participating in any other ophthalmic or non-ophthalmic drug/device clinical trials during the time of this clinical investigation.
Study Plan
How is the study designed?
Design Details
- Primary Purpose: Treatment
- Allocation: Non-Randomized
- Interventional Model: Parallel Assignment
- Masking: None (Open Label)
Number of Arms
Arms and Interventions
Participant Group / ArmParticipant Group / Arm |
Intervention / TreatmentIntervention / Treatment |
|---|---|
|
Experimental: Delayed
Intervention: Raindrop Near Vision Inlay In the delayed approach, the corneal pocket is created and dissected but the corneal inlay is not implanted. After one to three months, the corneal inlay is implanted on a second surgical day. |
The Raindrop Near Vision Inlay was approved by the US FDA in June of 2016 for the improvement of near vision in presbyopic emmetropes.
Raindrop is a clear device made of a hydrogel material and resembles a microscopic contact lens; it is the first implantable device that changes the shape of the cornea to correct the refractive errors that cause near vision problems.
|
|
Active Comparator: Non-Delayed
Intervention: Raindrop Near Vision Inlay In the non-delayed approach, the corneal pocket is created and inlay implanted on the same surgical day. |
The Raindrop Near Vision Inlay was approved by the US FDA in June of 2016 for the improvement of near vision in presbyopic emmetropes.
Raindrop is a clear device made of a hydrogel material and resembles a microscopic contact lens; it is the first implantable device that changes the shape of the cornea to correct the refractive errors that cause near vision problems.
|
What is the study measuring?
Primary Outcome Measures
Primary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Uncorrected Visual Acuity
Time Frame: 24 Months
|
After the inlay procedure, patients will attain functional near acuity in the inlay eye and functional distance vision binocularly.
|
24 Months
|
Secondary Outcome Measures
Secondary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Incidence of Corneal Reaction
Time Frame: 24 Months
|
Patients implanted with a delayed approach will have minimal incidence of corneal reaction as compared with non-delayed implantation.
|
24 Months
|
Collaborators and Investigators
Sponsor
Sponsor
Investigators
Investigators
- Principal Investigator: Bret L. Fisher, MD, Eye Center of North Florida
Study record dates
Study Major Dates
Study Start (Actual)
Study Start
Primary Completion (Actual)
Primary Completion
Study Completion (Actual)
Study Completion
Study Registration Dates
First Submitted
First Submitted
First Submitted That Met QC Criteria
First Submitted That Met QC Criteria
First Posted (Actual)
First Posted
Study Record Updates
Last Update Posted (Actual)
Last Update Posted
Last Update Submitted That Met QC Criteria
Last Update Submitted That Met QC Criteria
Last Verified
Last Verified
More Information
Terms related to this study
Additional Relevant MeSH Terms
Other Study ID Numbers
Other Study ID Numbers
- ECNF17-001
Plan for Individual participant data (IPD)
Plan to Share Individual Participant Data (IPD)?
Drug and device information, study documents
Studies a U.S. FDA-regulated drug product
Studies a U.S. FDA-regulated device product
product manufactured in and exported from the U.S.
This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.
Clinical Trials on Presbyopia
-
NCT07218731RecruitingPresbyopia | Presbyopia Correction
-
NCT02147093CompletedPresbyopia Correction
-
NCT06702020Active, not recruitingPresbyopia Correction
-
NCT06707545CompletedCataract | Presbyopia Correction
-
NCT06978556Active, not recruitingCataract | Presbyopia Correction
-
NCT05660577CompletedMyopia and Hyperopia and Presbyopia
-
NCT01628146Unknown
-
NCT06699784Not yet recruitingPresbyopia | Presbyopia Correction
-
NCT07008768CompletedCataract | Visual Acuity | Presbyopia Correction
Clinical Trials on Raindrop Near Vision Inlay
-
NCT02668523Unknown
-
NCT03017612Terminated
-
NCT03376412Unknown
-
NCT01373580Completed
-
NCT03242317Unknown
-
NCT04399811Not yet recruitingMachine Learning | Near-infrared Vision | Microcirculatory Status
-
NCT05458323RecruitingRefractive Errors
-
NCT05048550Active, not recruitingPremature Birth | Hypoxic-Ischemic Encephalopathy | Cerebral Visual Impairment | Refractive and Accommodative Disorders