Dielectric Property Test Compared With Frozen Pathological Section in the Rapid Diagnosis of Lung Nodules/Mass
Dielectric Property Test Compared With Frozen Pathological Section in the Rapid Diagnosis of Lung Nodules/Mass: a Diagnostic Clinical Trial
Study Overview
Status
Status
Conditions
Conditions
Intervention / Treatment
Intervention / Treatment
Study Type
Study Type
Enrollment (Anticipated)
Enrollment
Phase
Phase
- Not Applicable
Contacts and Locations
Study Contact
Study Contact
- Name: Di Lu, MD,PhD
- Phone Number: 86+13268379321
- Email: david_lu1989@163.com
Study Contact Backup
- Name: Siyang Feng, MD
- Phone Number: 86+13570930671
- Email: fengsy89@163.com
Study Locations
-
-
Guangdong
-
Guandong, Guangdong, China, 510515
- Recruiting
- Nanfang Hospital, Southern Medical University
-
Contact:
- Siyang Feng, MD
- Phone Number: 86+13570930671
- Email: fengsy89@163.com
-
Contact:
- Di Lu, MD, PhD
- Phone Number: 86+13268379321
- Email: david_lu189@163.com
-
-
Participation Criteria
Eligibility Criteria
Eligibility Criteria
Ages Eligible for Study
Accepts Healthy Volunteers
Genders Eligible for Study
Description
Inclusion Criteria:
- Patients with lung nodules/mass found by CT or PET who agree to receive lung resection;
- Diameter of the lung nodule/mass is longer than 8 millimeters;
- More than 50% of the lung nodule/mass is solid component by image examination;
- Diameter of the solid component is longer than 5 millimeters by intraoperative exploration.
Exclusion Criteria:
- Cutting open the resected nodule/mass will interfered with the pathological examination;
- Diameter of the solid component is shorter than 5 millimeters by intraoperative cutting open;
- Cutting open the lung nodule/mass will cause great damage to the patient, such as inducing allergic shock.
Study Plan
How is the study designed?
Design Details
- Primary Purpose: Diagnostic
- Allocation: Non-Randomized
- Interventional Model: Parallel Assignment
- Masking: None (Open Label)
Number of Arms
Arms and Interventions
Participant Group / ArmParticipant Group / Arm |
Intervention / TreatmentIntervention / Treatment |
|---|---|
|
Experimental: dielectric property test
The patient with lung nodules/mass is firstly arranged to be tested for dielectric property after the nodules/mass resection and cutting open.
|
Test the dielectric property of resected lung nodules/mass through a touching probe after the lung tissue with nodules/mass has been resected and cut open, which usually takes only 1-5 minutes.
|
|
Placebo Comparator: frozen pathological examination
The resected lung nodules/mass will be sent for frozen pathological examination after dielectric property test.
|
And after the dielectric property test, the lung tissue will be sent for frozen pathological examination.
|
|
Other: final pathological examination
The resected lung nodules/mass will undergo the final pathological examination for final diagnosis after dielectric property test and frozen pathological examination.
|
All of the lung nodules/mass will be diagnosed by final pathological examination and recognized as the final diagnosis after surgery.
|
What is the study measuring?
Primary Outcome Measures
Primary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
sensitivity of dielectric property test in diagnosing lung nodules/masses
Time Frame: 3-5 years
|
true positive rate in diagnosing lung nodules/masses
|
3-5 years
|
|
specificity of dielectric property test in diagnosing lung nodules/masses
Time Frame: 3-5 years
|
true negative rate in diagnosing lung nodules/masses
|
3-5 years
|
Collaborators and Investigators
Sponsor
Sponsor
Investigators
Investigators
- Principal Investigator: Di Lu, MD,PhD, Nanfang Hospital of Southern Medical University
Publications and helpful links
General Publications
- Gabriel C, Gabriel S, Corthout E. The dielectric properties of biological tissues: I. Literature survey. Phys Med Biol. 1996 Nov;41(11):2231-49. doi: 10.1088/0031-9155/41/11/001.
- Gabriel S, Lau RW, Gabriel C. The dielectric properties of biological tissues: II. Measurements in the frequency range 10 Hz to 20 GHz. Phys Med Biol. 1996 Nov;41(11):2251-69. doi: 10.1088/0031-9155/41/11/002.
- Gabriel S, Lau RW, Gabriel C. The dielectric properties of biological tissues: III. Parametric models for the dielectric spectrum of tissues. Phys Med Biol. 1996 Nov;41(11):2271-93. doi: 10.1088/0031-9155/41/11/003.
- Joines WT, Zhang Y, Li C, Jirtle RL. The measured electrical properties of normal and malignant human tissues from 50 to 900 MHz. Med Phys. 1994 Apr;21(4):547-50. doi: 10.1118/1.597312.
- Lu Y, Li B, Xu J, Yu J. Dielectric properties of human glioma and surrounding tissue. Int J Hyperthermia. 1992 Nov-Dec;8(6):755-60. doi: 10.3109/02656739209005023.
- Surowiec AJ, Stuchly SS, Barr JB, Swarup A. Dielectric properties of breast carcinoma and the surrounding tissues. IEEE Trans Biomed Eng. 1988 Apr;35(4):257-63. doi: 10.1109/10.1374. No abstract available.
- Fu F, Xin SX, Chen W. Temperature- and frequency-dependent dielectric properties of biological tissues within the temperature and frequency ranges typically used for magnetic resonance imaging-guided focused ultrasound surgery. Int J Hyperthermia. 2014 Feb;30(1):56-65. doi: 10.3109/02656736.2013.868534. Epub 2014 Jan 13.
Study record dates
Study Major Dates
Study Start (Actual)
Study Start
Primary Completion (Anticipated)
Primary Completion
Study Completion (Anticipated)
Study Completion
Study Registration Dates
First Submitted
First Submitted
First Submitted That Met QC Criteria
First Submitted That Met QC Criteria
First Posted (Actual)
First Posted
Study Record Updates
Last Update Posted (Actual)
Last Update Posted
Last Update Submitted That Met QC Criteria
Last Update Submitted That Met QC Criteria
Last Verified
Last Verified
More Information
Terms related to this study
Additional Relevant MeSH Terms
Other Study ID Numbers
Other Study ID Numbers
- NFEC-2017-070
Plan for Individual participant data (IPD)
Plan to Share Individual Participant Data (IPD)?
IPD Plan Description
Drug and device information, study documents
Studies a U.S. FDA-regulated drug product
Studies a U.S. FDA-regulated device product
product manufactured in and exported from the U.S.
This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.
Clinical Trials on Lung Nodules
-
NCT00613041CompletedLung Nodules | Undiagnosed Pulmonary Nodules
-
NCT07448441Not yet recruiting
-
NCT06762613Completed
-
NCT06728319Active, not recruiting
-
NCT02196974Completed
-
NCT07443540Not yet recruiting
-
NCT06821451Recruiting
-
NCT07057648RecruitingBronchoscopy | Lung Nodules | Peripheral Lung Lesions | Pulmonary Nodules | Lung Cancers
-
NCT06518655RecruitingLung Cancer | Pulmonary Nodules, Solitary | Pulmonary Nodules, Multiple
Clinical Trials on dielectric property test
-
NCT05405504Recruiting
-
NCT06942871CompletedPulmonary Hypertension
-
NCT06671067Not yet recruitingAcute Myocardial Infarction | Acute Decompensated Heart Failure (ADHF)
-
NCT07484009RecruitingAcute Heart Failure (AHF) | Heart Failure (for Example, Fluid Overload) | Heart Failure Hospitalization
-
NCT07600398Active, not recruitingAcute Heart Failure (AHF)
-
NCT05264337RecruitingTesticular Neoplasms | Prostatic Neoplasms | Urinary Bladder Neoplasms | Penile Cancer
-
NCT05149690Completed
-
NCT02448342Terminated
-
NCT02603211Completed