Reduction of Shear Forces Using Semi-flexible Sockets on Transtibial Amputees
Study Overview
Status
Status
Conditions
Conditions
Intervention / Treatment
Intervention / Treatment
Detailed Description
Study Type
Study Type
Enrollment (Actual)
Enrollment
Phase
Phase
- Not Applicable
Contacts and Locations
Study Locations
-
-
California
-
Loma Linda, California, United States, 92350
- Loma Linda Universtiy
-
-
Participation Criteria
Eligibility Criteria
Eligibility Criteria
Ages Eligible for Study
Accepts Healthy Volunteers
Genders Eligible for Study
Description
Inclusion Criteria:
- Transtibial amputee with mature limb
- Minimum of 3-years of prosthetic use
- Capable of ambulating on a treadmill for ten minutes
- Minimum age of 18 years old
- Both Unilateral and Bilateral Amputees
- K-Level K2-K4
Exclusion Criteria:
- Any open wounds/ulcerations on the residual limb
- Skin allergies to silicone or latex
- Unmanaged co-morbidities such a diabetes and congestive heart failure
Study Plan
How is the study designed?
Design Details
- Primary Purpose: Other
- Allocation: Randomized
- Interventional Model: Crossover Assignment
- Masking: None (Open Label)
Number of Arms
Arms and Interventions
Participant Group / ArmParticipant Group / Arm |
Intervention / TreatmentIntervention / Treatment |
|---|---|
|
Experimental: semi flexible socket group
A new form of residuum containment is the semi-flexible carbon fiber prosthetic socket.
A semi-flexible carbon fiber socket is constructed with the same security for the subject in mind, and is even more lightweight than a rigid socket.
The carbon fiber and resin used in a semi-flexible socket may provide the same durability and stability as previous designs, but will deform, intentionally, without failing (breaking).
This distinct feature of semi-flexible sockets makes them a potential option for people living with limb loss.
By moving slightly with the residual limb, the socket-user-interface should experience fewer forces/stresses, and yield greater comfort for the prosthetic user.
|
The investigators will analyze the subject's gait by trained visual diagnosis and video gait analysis, to determine comfort and safety.
Any modifications will be done at this time.
Once the subjects, student, and faculty investigators are satisfied with the overall fit of prostheses, a student investigator will insert force sensors into the socket to evaluate pressure.
In the 'Comfort Test', walk at a self-selected pace on a treadmill for 10 minutes.
Subjects will then perform a single stance activity on a Balance Master.
Investigators will remove the force sensors and do one final safety check of prostheses before each subject takes their definitive socket home.
Subjects will be required to wear the prosthesis given to them for one week before returning for a follow up appointment.
|
|
Active Comparator: rigid fiber socket group
A rigid carbon fiber socket is constructed for security and is mechanically lightweight to ensure stability and efficient build height.
Carbon is used for its durability and stability.
It proves to be a detriment in comfort and flexibility.
The standard for carbon fiber weaves come in two forms: Unidirectional (UD) and Bidirectional (BD).
UD carbon fiber has a zero-degree alignment, which is highly durable when compressed, but has low torsional durability.
The BD carbon fibers are aligned in a 90 degree angle allowing for moderate compression and torsional strength.
When oriented at 45 degrees to the line of progression, fibers become more flexible and exhibit greater torsional strength.
Resins and glass composites are added to ensure security and sturdiness.
|
The investigators will analyze the subject's gait by trained visual diagnosis and video gait analysis, to determine comfort and safety.
Any modifications will be done at this time.
Once the subjects, student, and faculty investigators are satisfied with the overall fit of prostheses, a student investigator will insert force sensors into the socket to evaluate pressure.
In the 'Comfort Test', walk at a self-selected pace on a treadmill for 10 minutes.
Subjects will then perform a single stance activity on a Balance Master.
Investigators will remove the force sensors and do one final safety check of prostheses before each subject takes their definitive socket home.
Subjects will be required to wear the prosthesis given to them for one week before returning for a follow up appointment.
|
What is the study measuring?
Primary Outcome Measures
Primary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Balance
Time Frame: Change in balance between Week 2 and Week 3 of study
|
The SMART Balance Master is a device used to measure balance.
It consists of a plate with force sensors that can measure the subject's center of gravity as the subject shifts their position back and forth through the exercise.
We will be exerting the subjects through the different phases of gait also known as a Limits of Stability test, one of the many pre-programed tests available to choose from.The SMART Balance Master is a widely used device in the rehabilitation world to test an individual's balance and ascertain their functional limits.
It is a device that has great repeatability and is used to test individuals rehabilitation progress.
It is also used extensively in research due to its high reproducibility.
The SMART Balance Master is manufactured by Natus Medical Incorporated which is located in Pleasanton California.
|
Change in balance between Week 2 and Week 3 of study
|
Secondary Outcome Measures
Secondary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Socket liner integrity
Time Frame: Change in socket liner between Week 2 and Week 3 of study
|
The Socket Liner Integrity Checklist (SLIC) has been developed by one of our student investigators which has worked in the industry for 9 years.
The SLIC will be used to evaluate the wear that the socket exerts on the liner.
We hypothesize that semi-flexible sockets will reduce wear of the liner, and we will use the SLIC to evaluate.
The semi-flexible socket will also need to be evaluated.
A semi-flexible socket might be a more comfortable experience for the user but if it does not hold up to the rigours of daily activities wear and tear, it is not a better alternative.
This checklist will focus on specific areas of that socket which are prone to failure to more easily catch any major flaws.
|
Change in socket liner between Week 2 and Week 3 of study
|
Collaborators and Investigators
Sponsor
Sponsor
Investigators
Investigators
- Principal Investigator: Gurinder Bains, PhD, Loma Linda University
Study record dates
Study Major Dates
Study Start (Actual)
Study Start
Primary Completion (Actual)
Primary Completion
Study Completion (Actual)
Study Completion
Study Registration Dates
First Submitted
First Submitted
First Submitted That Met QC Criteria
First Submitted That Met QC Criteria
First Posted (Actual)
First Posted
Study Record Updates
Last Update Posted (Actual)
Last Update Posted
Last Update Submitted That Met QC Criteria
Last Update Submitted That Met QC Criteria
Last Verified
Last Verified
More Information
Terms related to this study
Other Study ID Numbers
Other Study ID Numbers
- 5170454
Plan for Individual participant data (IPD)
Plan to Share Individual Participant Data (IPD)?
Drug and device information, study documents
Studies a U.S. FDA-regulated drug product
Studies a U.S. FDA-regulated device product
This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.