Clinical Evaluation of FLACS With Combination of LenSx® and Centurion®
Clinical Evaluation of FLACS (Femtosecond Laser Assisted Cataract Surgery) With Combination of LenSx® and Centurion®
Study Overview
Status
Status
Conditions
Conditions
Intervention / Treatment
Intervention / Treatment
Detailed Description
Study Type
Study Type
Enrollment (Actual)
Enrollment
Phase
Phase
- Not Applicable
Contacts and Locations
Study Locations
-
-
Fukuoka
-
Iizuka City, Fukuoka, Japan, 820-0067
- Alcon Investigative Site
-
-
Participation Criteria
Eligibility Criteria
Eligibility Criteria
Ages Eligible for Study
Accepts Healthy Volunteers
Genders Eligible for Study
Description
Inclusion Criteria:
- Cataracts (Grade 2-4 of Emery-Little Classification) with planned cataract removal by phacoemulsification in both eyes;
- Able to comprehend and willing to sign informed consent and complete all required postoperative follow-up procedures;
- Calculated lens power within the available range;
- Other protocol-specified inclusion criteria may apply.
Exclusion Criteria:
- Any pathology that could reduce visual potential;
- Hypotony or the presence of a corneal implant;
- Residual, recurrent, active ocular or eyelid disease;
- Poorly dilating pupil;
- Any contraindication to cataract;
- Eyes with two different levels of cataract grade;
- Pregnant, or planned pregnancy during the study;
- Expected to require an ocular surgical treatment at any time during the study;
- Other protocol-specified exclusion criteria may apply.
Study Plan
How is the study designed?
Design Details
- Primary Purpose: Treatment
- Allocation: Randomized
- Interventional Model: Parallel Assignment
- Masking: Single
Number of Arms
Arms and Interventions
Participant Group / ArmParticipant Group / Arm |
Intervention / TreatmentIntervention / Treatment |
|---|---|
|
Experimental: FLACS
Femtosecond laser assisted cataract surgery (FLACS) in 1 eye, with manual conventional surgery in the fellow eye, as randomized
|
Femtosecond laser assisted cataract surgery consisting of LenSx® and Centurion® combination
Phacoemulsification aspiration platform for use during cataract surgery
Femtosecond laser system used for continuous curvilinear capsulorhexis (CCC) and lens fragmentation during cataract surgery
|
|
Active Comparator: Conventional
Manual conventional surgery in 1 eye, with FLACS in the fellow eye, as randomized
|
Phacoemulsification aspiration platform for use during cataract surgery
Removal of cataractous lens by phacoemulsification
|
What is the study measuring?
Primary Outcome Measures
Primary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Cumulative Dissipated Energy (CDE)
Time Frame: Day 0 (operative day)
|
CDE is not expressed in standard units such as Watts or Joules and accounts for the power and time of longitudinal and torsional ultrasound delivery modes.
CDE (the sum total of phacoemulsification energy dissipated at the incision point during the removal of cataractous lens with Centurion® Vision System footpedal in Position 3) was calculated by the Centurion® Vision System as follows: CDE = (Longitudinal time) x (Average longitudinal power) + (Torsional time x 0.4 x Average torsional amplitude).
A lower CDE value indicates that less energy was expended in the eye.
|
Day 0 (operative day)
|
Secondary Outcome Measures
Secondary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Percent Change of Corneal Endothelial Cell Density (ECD) at Visit 5 (150-210 Days After Surgery) From Pre-Operative Visit
Time Frame: Preoperative, Day 150-210 (post-operative)
|
Central endothelial cell counts were assessed using specular microscopy.
ECD was measured in cells per square millimeter (mm2).
The endothelium maintains corneal hydration, and positive percent change value indicates an improvement.
In turn, a less negative percent change value is preferable over a more negative percent change value.
|
Preoperative, Day 150-210 (post-operative)
|
|
Percentage of Average Torsional Amplitude
Time Frame: Day 0 (operative day)
|
Torsional amplitude (the amplitude of the oscillations of the phacoemulsification tip) was reported on the Centurion® Vision System interface as a percentage from 0 to 100, where 100 represents maximum amplitude.
A lower percentage value indicates greater efficiency in the phacoemulsification process.
|
Day 0 (operative day)
|
Collaborators and Investigators
Sponsor
Sponsor
Investigators
Investigators
- Study Director: Alcon, A Novartis Division, Alcon, A Novartis Division
Study record dates
Study Major Dates
Study Start (Actual)
Study Start
Primary Completion (Actual)
Primary Completion
Study Completion (Actual)
Study Completion
Study Registration Dates
First Submitted
First Submitted
First Submitted That Met QC Criteria
First Submitted That Met QC Criteria
First Posted (Actual)
First Posted
Study Record Updates
Last Update Posted (Actual)
Last Update Posted
Last Update Submitted That Met QC Criteria
Last Update Submitted That Met QC Criteria
Last Verified
Last Verified
More Information
Terms related to this study
Additional Relevant MeSH Terms
Other Study ID Numbers
Other Study ID Numbers
- CTB258-P001
Plan for Individual participant data (IPD)
Plan to Share Individual Participant Data (IPD)?
Drug and device information, study documents
Studies a U.S. FDA-regulated drug product
Studies a U.S. FDA-regulated device product
product manufactured in and exported from the U.S.
This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.