Contrast Enhanced Spectral Mammography vs. MRI for Breast Cancer Screening
Study Overview
Status
Status
Conditions
Conditions
Intervention / Treatment
Intervention / Treatment
Detailed Description
Mammography is the main way to help find breast cancers early so they can be treated. Unfortunately, mammography does not work as well in women who have dense breast tissue or who are at high-risk for breast cancer. In these women, breast MRI is also used to help find breast cancers.
Contrast enhanced mammography is a new type of mammogram. It uses contrast material combined with the mammogram to highlight areas that might be breast cancer and that could be missed on the mammogram alone. This is similar to breast MRI.
For this study, participants who had both CEM and MRI evaluating a finding that initiated from a screening exam will be included. Radiologists will compare the images to see if the contrast enhanced mammograms and the breast MRI find the same number of breast cancers. If the investigators find they perform similarly, then contrast mammography may be used to aid in breast cancer screening in the future.
Study Type
Study Type
Enrollment (Actual)
Enrollment
Phase
Phase
- Not Applicable
Contacts and Locations
Study Locations
-
-
Massachusetts
-
Boston, Massachusetts, United States, 02215
- Beth Israel Deaconess
-
-
Participation Criteria
Eligibility Criteria
Eligibility Criteria
Ages Eligible for Study
Accepts Healthy Volunteers
Description
Inclusion Criteria:
- CESM and MRI exam performed within 3 months of one another.
- CESM and breast MRI exams must be performed as part of imaging work-up based on a screening exam of any type (mammography, tomosynthesis, ultrasound, and MRI)
- CESM studies will include at least four low energy and four recombined images (LCC, LMLO, RCC, RMLO).
- MRI exams will include at least fluid sensitive sequence, multi-phase T1-weighted
Exclusion Criteria:
- Imaging sets with implants.
- Imaging sets in which a biopsy or surgical intervention was performed since the most recent screening exam, prior to acquisition of the study MRI or CESM.
- Imaging sets in which a biopsy was recommended, but biopsy was not performed and 2 year imaging follow-up is not available
Study Plan
How is the study designed?
Design Details
- Primary Purpose: Screening
- Allocation: Randomized
- Interventional Model: Single Group Assignment
- Masking: None (Open Label)
Number of Arms
Arms and Interventions
Participant Group / ArmParticipant Group / Arm |
Intervention / TreatmentIntervention / Treatment |
|---|---|
|
Experimental: Contrast-Enhanced Spectral Mammography
Each enrolled participant will receive a CESM either at the time of screening or following screening, for a screen detected finding.
If patient has a biopsy for a finding, the CESM must be performed prior to biopsy.
|
Contrast enhanced mammography is a new type of mammogram.
It uses contrast material combined with the mammogram to highlight areas that might be breast cancer and that could be missed on the mammogram alone
Other Names:
|
|
Experimental: Breast MRI
Each enrolled participant will receive an MRI exam either at the time of screening or following screening, for a screen detected finding.
If patient has a biopsy for a finding, the MRI must be performed prior to biopsy.
|
MRI uses magnets to create a detailed image of the tissues and bones inside of the body
Other Names:
|
What is the study measuring?
Primary Outcome Measures
Primary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Area Under the Curve for Cancer Detection Rates of CESM Compared With Breast MRI for Breast Cancer Screening
Time Frame: 2 years
|
We will determine whether CESM is non-inferior to breast MRI for breast cancer detection by comparing cancer detection rates on both studies using a multi-case multi-reader study model.
|
2 years
|
Secondary Outcome Measures
Secondary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Area Under the Curve for Cancer Detection Rates of CESM Compared With Abbreviated Breast MRI for Breast Cancer Screening
Time Frame: 2 years
|
Radiologist readers evaluated CEM and abbreviated MRI in 132 patients, some who had cancer and some who did not.
The area under the curve was determine for each reader for each exam type.
|
2 years
|
|
Area Under the Curve for Cancer Detection Rates of CESM Compared With Conventional 2d Mammography for Breast Cancer Screening
Time Frame: 2 years
|
We will determine whether CESM is superior to conventional 2D mammographic screening using a multi-case multi-reader study model.
|
2 years
|
Collaborators and Investigators
Sponsor
Sponsor
Collaborators
Collaborators
Investigators
Investigators
- Principal Investigator: Olga Brook, MD, Beth Israel Deaconess Medical Center
Study record dates
Study Major Dates
Study Start (Actual)
Study Start
Primary Completion (Actual)
Primary Completion
Study Completion (Actual)
Study Completion
Study Registration Dates
First Submitted
First Submitted
First Submitted That Met QC Criteria
First Submitted That Met QC Criteria
First Posted (Actual)
First Posted
Study Record Updates
Last Update Posted (Actual)
Last Update Posted
Last Update Submitted That Met QC Criteria
Last Update Submitted That Met QC Criteria
Last Verified
Last Verified
More Information
Terms related to this study
Additional Relevant MeSH Terms
Other Study ID Numbers
Other Study ID Numbers
- 17-689
Plan for Individual participant data (IPD)
Plan to Share Individual Participant Data (IPD)?
Drug and device information, study documents
Studies a U.S. FDA-regulated drug product
Studies a U.S. FDA-regulated device product
product manufactured in and exported from the U.S.
This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.