Early Experience of a New Implant System for Bone Conduction Hearing in the Pediatric Population (OSIA Pediatric)
Study Overview
Status
Status
Conditions
Conditions
Intervention / Treatment
Intervention / Treatment
Detailed Description
Experimental: Bone-conduction hearing device The bone-conduction hearing device Osia system allows a direct bone-conduction through an osseointegrated implant. A magnet allows the external Sound Processor to be placed in the correct position over the implanted system including an inner magnet.
Device: Osia System An external Sound Processor captures and digitize the sound which is transferred to the internal implant where it is converted to an electrical signal. The electrical signal is further transferred as a vibration through an osseointegrated implant to the mastoid bone and eventually to the cochlea
Study Type
Study Type
Enrollment (Actual)
Enrollment
Phase
Phase
- Not Applicable
Contacts and Locations
Study Locations
-
-
Ontario
-
Toronto, Ontario, Canada, M5G1X8
- The Hospital for Sick Children
-
-
Participation Criteria
Eligibility Criteria
Eligibility Criteria
Ages Eligible for Study
Accepts Healthy Volunteers
Genders Eligible for Study
Description
Inclusion Criteria: Individuals 5 through 18 years of age will be eligible for inclusion in the investigation if all of the criteria below are met:
Conductive or mixed hearing loss in the ear to be implanted. Bone conduction thresholds with pure-tone average (PTA4; mean of 0.5, 1, 2, and 4 kHz) of less than or equal to 55 dB HL.
Subject does not benefit from or will not wear a conventional hearing aid.
Note: Candidates may include individuals seeking new implantation unilaterally (in one ear) or bilaterally (both ears) as well as individuals already implanted with a bone-anchored device seeking a second-side implant.
OR
Single-sided sensorineural deafness who is a candidate for Baha surgery. Air conduction thresholds with a pure-tone average (PTA4; mean of 0.5, 1, 2, and 3 kHz) of less that equal to 20 dB HL in the good ear.
Subject does not benefit from or will not wear a conventional hearing aid
Exclusion Criteria:
Uncontrolled diabetes as judged by the investigator. Subject who has received radiotherapy in the area of implantation, or such radiotherapy is planned during the study period.
Current use of ototoxic drugs. Condition that could jeopardize osseointegration and/or wound healing or condition that may have an impact on the outcome of the investigation as judged by the investigator.
Insufficient bone quality and quantity for implantation of a BI300 Implant, as determined by the surgeon.
Unable to follow investigational procedures. Participation in another clinical investigation with pharmaceutical and/or device
Study Plan
How is the study designed?
Design Details
- Primary Purpose: Treatment
- Allocation: N/A
- Interventional Model: Single Group Assignment
- Masking: None (Open Label)
Number of Arms
Arms and Interventions
Participant Group / ArmParticipant Group / Arm |
Intervention / TreatmentIntervention / Treatment |
|---|---|
|
Experimental: Bone Anchored Hearing Device (OSIA)
All subjects will receive the Bone Anchored Hearing Device (OSIA)
|
Bone anchored, bone conduction hearing system
Other Names:
|
What is the study measuring?
Primary Outcome Measures
Primary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Number of Participants Reporting Type and Severity of Adverse Events in the Pediatric Population Implanted With the Osia System
Time Frame: Surgery to 12 months post-operative
|
Number, Type and Severity of Adverse Events will be tabulated and summarized.
|
Surgery to 12 months post-operative
|
Collaborators and Investigators
Sponsor
Sponsor
Study record dates
Study Major Dates
Study Start (Actual)
Study Start
Primary Completion (Actual)
Primary Completion
Study Completion (Actual)
Study Completion
Study Registration Dates
First Submitted
First Submitted
First Submitted That Met QC Criteria
First Submitted That Met QC Criteria
First Posted (Actual)
First Posted
Study Record Updates
Last Update Posted (Actual)
Last Update Posted
Last Update Submitted That Met QC Criteria
Last Update Submitted That Met QC Criteria
Last Verified
Last Verified
More Information
Terms related to this study
Additional Relevant MeSH Terms
Other Study ID Numbers
Other Study ID Numbers
- CAM5706
Plan for Individual participant data (IPD)
Plan to Share Individual Participant Data (IPD)?
Drug and device information, study documents
Studies a U.S. FDA-regulated drug product
Studies a U.S. FDA-regulated device product
product manufactured in and exported from the U.S.
This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.
Clinical Trials on Unilateral Mixed Conductive and Sensorineural Hearing Loss (Diagnosis)
-
NCT01264510WithdrawnConductive Hearing Loss | Unilateral Deafness | Mixed Hearing Loss
-
NCT02722330CompletedSingle Sided Sensorineural Deafness | Mixed Hearing Loss, Unilateral
-
NCT02438618CompletedConductive Hearing Loss | Unilateral Partial Deafness | Mixed Conductive-sensorineural Hearing Loss
-
NCT04803279CompletedEar Diseases | Hearing Loss, Conductive | Hearing Loss Mixed | Hearing Disability | Conductive Hearing Loss | Conductive Hearing Loss, Bilateral | Conductive Hearing Loss, Unilateral
-
NCT04427033CompletedHearing Loss | Hearing Loss, Sensorineural | Hearing Loss, Bilateral | Hearing Loss, Conductive | Hearing Loss, Unilateral | Hearing Loss, Mixed
-
NCT02274129CompletedConductive Hearing Loss | Mixed Hearing Loss | Unilateral Partial Deafness
-
NCT02304692CompletedConductive Hearing Loss | Mixed Hearing Loss | Unilateral Partial Deafness
-
NCT03333577CompletedHearing Loss, Conductive | Hearing Loss, Unilateral | Hearing Loss, Mixed
-
NCT05166265Active, not recruitingHearing Loss, Conductive | Hearing Loss, Unilateral | Hearing Loss, Mixed
-
NCT01529333UnknownMixed Conductive and Sensorineural Hearing Loss, Bilateral
Clinical Trials on Osseointegrated Steady State Implant
-
NCT04040517UnknownHearing Impaired Children
-
NCT05675852RecruitingVisual Neurosciences
-
NCT05296109RecruitingParotid Neoplasms
-
NCT05625789Completed
-
NCT01796080CompletedPatients With Paroxysmal Atrial Fibrillation
-
NCT03822728CompletedFacial Nerve Paresis | Parotid Tumors
-
NCT03284216CompletedHyperglycemia | Aerobic Exercise | Glucose Metabolism Disorders (Including Diabetes Mellitus)