Endotracheal Tube Shapes for Intubation With Videolaryngoscope
Comparison of Endotracheal Tube Shapes for Intubation With Videolaryngoscope in Normal Airways
Study Overview
Status
Status
Conditions
Conditions
Intervention / Treatment
Intervention / Treatment
Detailed Description
Since the intubation using videolaryngoscope does not need straightened oral-pharyngeal-laryngeal axis, certain curvature of endotracheal tube is needed for the successful intubation using the videolaryngoscope.
Participants in both groups will be intubated with videolaryngoscope (McGrath MAC®). Stylet will be inserted in the endotracheal tubes and will be bent to a specific shape by the assigned group. In the J-shaped tube group, endotracheal tube will be molded to a shape similar to the blade of the videolaryngoscope (McGrath MAC®). In the 60-degrees-curved tube group, endotracheal tube will be bent 60 degrees. Time to intubation, intubation attempts and ease of intubation wil be assessed.
Study Type
Study Type
Enrollment (Actual)
Enrollment
Phase
Phase
- Not Applicable
Contacts and Locations
Study Locations
-
-
-
Seoul, Korea, Republic of, 03181
- Kangbuk Samsung Hospital
-
-
Participation Criteria
Eligibility Criteria
Eligibility Criteria
Ages Eligible for Study
Accepts Healthy Volunteers
Genders Eligible for Study
Description
Inclusion Criteria:
- Patients scheduled for the surgery under general anesthesia
- Adult patients from 18 years to 65 years
- American society of Anesthesiologist physical status 1,2,3
Exclusion Criteria:
- Previously diagnosed for the difficult intubation
- Pregnancy
- Obesity (Body mass index over 40 g/m^2)
Study Plan
How is the study designed?
Design Details
- Primary Purpose: Supportive Care
- Allocation: Randomized
- Interventional Model: Parallel Assignment
- Masking: Double
Number of Arms
Arms and Interventions
Participant Group / ArmParticipant Group / Arm |
Intervention / TreatmentIntervention / Treatment |
|---|---|
|
Experimental: J-shaped
Endotracheal tube will be molded into a J-shape that is similar to that of Macintosh type blade of a McGrath MAC® videolaryngoscope.
|
After inserting a stylet into the endotracheal tube, the tube will be molded into a J-shape.
|
|
Active Comparator: 60-degrees
Endotracheal tube will be bent 60 degrees.
|
After inserting a stylet into the endotracheal tube, the tube will be bent 60-degrees.
|
What is the study measuring?
Primary Outcome Measures
Primary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Time to intubate
Time Frame: 20 minutes after induction started.
|
the time took from the blade passing through the incisor teeth of the patient to the first end tidal CO2 appears on the anesthesia monitor screen.
|
20 minutes after induction started.
|
Secondary Outcome Measures
Secondary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Numbers of intubation attempts
Time Frame: 20 minutes after induction started.
|
numbers of attempts for the successful endotracheal intubation
|
20 minutes after induction started.
|
|
Level of difficulty in intubation
Time Frame: 20 minutes after induction started.
|
easy, moderate, difficult
|
20 minutes after induction started.
|
Collaborators and Investigators
Sponsor
Sponsor
Investigators
Investigators
- Principal Investigator: Hyunyoung Lim, M.D., Hanyang University
Study record dates
Study Major Dates
Study Start (Actual)
Study Start
Primary Completion (Actual)
Primary Completion
Study Completion (Actual)
Study Completion
Study Registration Dates
First Submitted
First Submitted
First Submitted That Met QC Criteria
First Submitted That Met QC Criteria
First Posted (Actual)
First Posted
Study Record Updates
Last Update Posted (Actual)
Last Update Posted
Last Update Submitted That Met QC Criteria
Last Update Submitted That Met QC Criteria
Last Verified
Last Verified
More Information
Terms related to this study
Other Study ID Numbers
Other Study ID Numbers
- 2018-01-033-001
- 2018-01-016-003 (Other Identifier: Hanyang university hospital)
Plan for Individual participant data (IPD)
Plan to Share Individual Participant Data (IPD)?
Drug and device information, study documents
Studies a U.S. FDA-regulated drug product
Studies a U.S. FDA-regulated device product
This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.