veRy Thin Stents for Patients With Left mAIn or bifurcatioN in Real Life: the RAIN a Multicenter Study (RAIN)
Study Overview
Status
Status
Conditions
Conditions
Intervention / Treatment
Intervention / Treatment
Detailed Description
Study Type
Study Type
Enrollment (Actual)
Enrollment
Contacts and Locations
Study Locations
-
-
-
Turin, Italy, 10128
- Città della Salute
-
-
Participation Criteria
Eligibility Criteria
Eligibility Criteria
Ages Eligible for Study
Accepts Healthy Volunteers
Genders Eligible for Study
Sampling Method
Study Population
Description
Inclusion Criteria:
- Patients undergoing PCI on unprotected left main or coronary bifurcation
Exclusion Criteria:
- PCI performed on other coronary vessels
Study Plan
How is the study designed?
Design Details
- Observational Models: Cohort
- Time Perspectives: Prospective
Number of groups / cohorts
Cohorts and Interventions
Group / CohortGroup / Cohort |
Intervention / TreatmentIntervention / Treatment |
|---|---|
|
Group
Consecutive patients treated with very thin stents on ULM and bifurcation
|
PCI will be performed
|
What is the study measuring?
Primary Outcome Measures
Primary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Major Adverse Cardiac Events (MACE)
Time Frame: 1 year
|
Major Adverse Cardiac Events (MACE) is a composite end-point which includes: death for any cause; non fatal myocardial infarction; target lesion revascularization (TLR); in-stent thrombosis.
|
1 year
|
Secondary Outcome Measures
Secondary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Target Lesion revascularization (TLR)
Time Frame: 1 year
|
The investigators defined Target Lesion Revascularization as either repeat percutaneous or surgical revascularization for a lesion anywhere within the stent or the 5-mm borders proximal or distal to the stent.
|
1 year
|
|
Death
Time Frame: 1 year
|
Death for any cause (both cardiologic and non-cardiologic)
|
1 year
|
|
non fatal myocardial infarction
Time Frame: 1 year
|
non fatal myocardial infarction
|
1 year
|
|
Target Vessel Revascularization (TVR)
Time Frame: 1 year
|
TVR is defined as any repeat PCI in the target vessel indicating the disease progression.
|
1 year
|
Collaborators and Investigators
Sponsor
Sponsor
Collaborators
Collaborators
Publications and helpful links
General Publications
- Iannaccone M, Barbero U, De Benedictis M, Imori Y, Quadri G, Trabattoni D, Ryan N, Venuti G, Montabone A, Wojakowski W, Rognoni A, Helft G, Parma R, De Luca L, Autelli M, Boccuzzi G, Mattesini A, Templin C, Cerrato E, Wanha W, Smolka G, Huczek Z, Tomassini F, Cortese B, Capodanno D, Chieffo A, Nunez-Gil I, Gili S, Bassignana A, di Mario C, Doronzo B, Omede P, D'Amico M, Tedeschi D, Varbella F, Luscher T, Sheiban I, Escaned J, Rinaldi M, D'Ascenzo F. Comparison of bioresorbable vs durable polymer drug-eluting stents in unprotected left main (from the RAIN-CARDIOGROUP VII Study). BMC Cardiovasc Disord. 2020 May 15;20(1):225. doi: 10.1186/s12872-020-01420-5.
- Gaido L, D'Ascenzo F, Imori Y, Wojakowski W, Saglietto A, Figini F, Mattesini A, Trabattoni D, Rognoni A, Tomassini F, Bernardi A, Ryan N, Muscoli S, Helft G, De Filippo O, Parma R, De Luca L, Ugo F, Cerrato E, Montefusco A, Pennacchi M, Wanha W, Smolka G, de Lio G, Bruno F, Huczek Z, Boccuzzi G, Cortese B, Capodanno D, Omede P, Mancone M, Nunez-Gil I, Romeo F, Varbella F, Rinaldi M, Escaned J, Conrotto F, Burzotta F, Chieffo A, Perl L, D'Amico M, di Mario C, Sheiban I, Gagnor A, Giammaria M, De Ferrari GM. Impact of Kissing Balloon in Patients Treated With Ultrathin Stents for Left Main Lesions and Bifurcations: An Analysis From the RAIN-CARDIOGROUP VII Study. Circ Cardiovasc Interv. 2020 Mar;13(3):e008325. doi: 10.1161/CIRCINTERVENTIONS.119.008325. Epub 2020 Feb 27.
Study record dates
Study Major Dates
Study Start (Actual)
Study Start
Primary Completion (Actual)
Primary Completion
Study Completion (Actual)
Study Completion
Study Registration Dates
First Submitted
First Submitted
First Submitted That Met QC Criteria
First Submitted That Met QC Criteria
First Posted (Actual)
First Posted
Study Record Updates
Last Update Posted (Actual)
Last Update Posted
Last Update Submitted That Met QC Criteria
Last Update Submitted That Met QC Criteria
Last Verified
Last Verified
More Information
Terms related to this study
Additional Relevant MeSH Terms
Other Study ID Numbers
Other Study ID Numbers
- RAIN
Drug and device information, study documents
Studies a U.S. FDA-regulated drug product
Studies a U.S. FDA-regulated device product
product manufactured in and exported from the U.S.
This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.