The Effect of Electrical Stimulation on Impairment of the Painful Post-Stroke Shoulder
Study Overview
Status
Status
Conditions
Conditions
Intervention / Treatment
Intervention / Treatment
Detailed Description
Study Type
Study Type
Enrollment (Actual)
Enrollment
Phase
Phase
- Not Applicable
Participation Criteria
Eligibility Criteria
Eligibility Criteria
Ages Eligible for Study
Accepts Healthy Volunteers
Genders Eligible for Study
Description
Inclusion Criteria:
- at least 3 months post-stroke
- worst shoulder pain in the last week at least 4 on the 0-10 numerical rating scale,
- adequate cognitive ability to be able to rate their pain in the past week
Exclusion Criteria:
- history of tachyarrhythmia with decreased blood pressure
- uncontrolled seizures (defined as more than one per month)
- an implanted electrical device
- uncompensated hemi-neglect
Study Plan
How is the study designed?
Design Details
- Primary Purpose: Treatment
- Allocation: N/A
- Interventional Model: Single Group Assignment
- Masking: None (Open Label)
Number of Arms
Arms and Interventions
Participant Group / ArmParticipant Group / Arm |
Intervention / TreatmentIntervention / Treatment |
|---|---|
|
Experimental: TENS/t-NMES/No stimulation
TENS stimulation parameters were of a symmetric waveform, a frequency of 100 Hz, and a pulse duration of 300 microseconds (EMPI 300PVTM program PPR #7) applied for 10 seconds.
t-NMES parameters were a symmetric waveform with 2 second ramp-up and 2 second ramp-down, a frequency of 35Hz, and a pulse duration of 300 microseconds (EMPI 300PVTM program PPR #3).
The t-NMES current intensity was set by adjusting the amplitude to yield the strongest contraction of the underlying muscles without initiating pain.
Device and electrodes remained in place but no stimulation was delivered over the 10 second interval.
Exposed to each stimulation 3 times for each shoulder ROM.
|
Electrical Stimulation
Other Names:
Electrical Stimulation
Other Names:
No stimulation
|
What is the study measuring?
Primary Outcome Measures
Primary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Passive Range of Motion of Shoulder in Shoulder External Rotation
Time Frame: 10 seconds
|
passive range of motion of shoulder in shoulder external rotation as measured with hand-held goniometer
|
10 seconds
|
|
Passive Range of Motion of Shoulder in Shoulder Abduction
Time Frame: 10 seconds
|
passive range of motion of shoulder in shoulder abduction as measured with hand-held goniometer
|
10 seconds
|
Collaborators and Investigators
Sponsor
Sponsor
Investigators
Investigators
- Principal Investigator: John Chae, MD, MetroHealth Medical Center
Publications and helpful links
General Publications
- Sluka KA, Deacon M, Stibal A, Strissel S, Terpstra A. Spinal blockade of opioid receptors prevents the analgesia produced by TENS in arthritic rats. J Pharmacol Exp Ther. 1999 May;289(2):840-6.
- Soo Hoo J, Paul T, Chae J, Wilson RD. Central hypersensitivity in chronic hemiplegic shoulder pain. Am J Phys Med Rehabil. 2013 Jan;92(1):1-9; quiz 10-3. doi: 10.1097/PHM.0b013e31827df862.
- Chantraine A, Baribeault A, Uebelhart D, Gremion G. Shoulder pain and dysfunction in hemiplegia: effects of functional electrical stimulation. Arch Phys Med Rehabil. 1999 Mar;80(3):328-31. doi: 10.1016/s0003-9993(99)90146-6.
- Faghri PD, Rodgers MM, Glaser RM, Bors JG, Ho C, Akuthota P. The effects of functional electrical stimulation on shoulder subluxation, arm function recovery, and shoulder pain in hemiplegic stroke patients. Arch Phys Med Rehabil. 1994 Jan;75(1):73-9.
- Leandri M, Parodi CI, Corrieri N, Rigardo S. Comparison of TENS treatments in hemiplegic shoulder pain. Scand J Rehabil Med. 1990;22(2):69-71.
- Roosink M, Renzenbrink GJ, Buitenweg JR, van Dongen RT, Geurts AC, Ijzerman MJ. Somatosensory symptoms and signs and conditioned pain modulation in chronic post-stroke shoulder pain. J Pain. 2011 Apr;12(4):476-85. doi: 10.1016/j.jpain.2010.10.009. Epub 2010 Dec 17.
Study record dates
Study Major Dates
Study Start (Actual)
Study Start
Primary Completion (Actual)
Primary Completion
Study Completion (Actual)
Study Completion
Study Registration Dates
First Submitted
First Submitted
First Submitted That Met QC Criteria
First Submitted That Met QC Criteria
First Posted (Actual)
First Posted
Study Record Updates
Last Update Posted (Actual)
Last Update Posted
Last Update Submitted That Met QC Criteria
Last Update Submitted That Met QC Criteria
Last Verified
Last Verified
More Information
Terms related to this study
Keywords
Additional Relevant MeSH Terms
Other Study ID Numbers
Other Study ID Numbers
- IRB10-00491
Plan for Individual participant data (IPD)
Plan to Share Individual Participant Data (IPD)?
Drug and device information, study documents
Studies a U.S. FDA-regulated drug product
Studies a U.S. FDA-regulated device product
product manufactured in and exported from the U.S.
This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.