Registry to Monitor Berlin Heart EXCOR® Pediatric VAD as a Bridge to Cardiac Transplantation.
All-comers Registry Monitoring the Safety and Effectiveness of the Berlin Heart EXCOR® Pediatric VAD as a Bridge to Cardiac Transplantation.
Study Overview
Status
Status
Conditions
Conditions
Intervention / Treatment
Intervention / Treatment
Detailed Description
Study Type
Study Type
Enrollment (Anticipated)
Enrollment
Contacts and Locations
Study Locations
-
-
Ohio
-
Cincinnati, Ohio, United States, 45229
- Sites per Action network
-
-
Participation Criteria
Eligibility Criteria
Eligibility Criteria
Ages Eligible for Study
Accepts Healthy Volunteers
Genders Eligible for Study
Sampling Method
Study Population
Description
Inclusion Criteria:
- Transplant eligible
- Implanted with EXCOR Pediatric per IFU
Exclusion Criteria:
- Having any contradictions for user per IFU
Study Plan
How is the study designed?
Design Details
- Observational Models: Cohort
- Time Perspectives: Prospective
Number of groups / cohorts
Cohorts and Interventions
Group / CohortGroup / Cohort |
Intervention / TreatmentIntervention / Treatment |
|---|---|
|
EXCOR Pediatric
Pediatric (age 0 - 21) patients who are transplant eligible in need of mechanical circulatory support and are supported with the EXCOR® Pediatric
|
Mechanical circulatory support using ventricular assist device
Other Names:
|
What is the study measuring?
Primary Outcome Measures
Primary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Stroke rate
Time Frame: Until discontinuation of device support or 180 days
|
The primary endpoint is to demonstrate that the rate of stroke (ischemic or hemorrhagic) will be no worse than the pre-specified performance goal.
The rate will be calculated as the proportion of subjects experiencing a stroke while on EXCOR® Pediatric support within the first 180 days post-implant.
The upper bound of the 95% confidence interval for the observed stroke rate will be compared to the pre-specified performance goal of 30%.
|
Until discontinuation of device support or 180 days
|
Secondary Outcome Measures
Secondary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Adverse Events
Time Frame: Until discontinuation of device support or 180 days
|
Adverse Event rates per patient-month
|
Until discontinuation of device support or 180 days
|
|
Device effectiveness
Time Frame: Until discontinuation of device support or 180 days
|
Proportion of subjects experiencing a successful (transplant, wean for recovery) outcome
|
Until discontinuation of device support or 180 days
|
Collaborators and Investigators
Sponsor
Sponsor
Investigators
Investigators
- Study Director: Robert M Kroslowitz, BS, Berlin Heart, Inc
Study record dates
Study Major Dates
Study Start (Anticipated)
Study Start
Primary Completion (Anticipated)
Primary Completion
Study Completion (Anticipated)
Study Completion
Study Registration Dates
First Submitted
First Submitted
First Submitted That Met QC Criteria
First Submitted That Met QC Criteria
First Posted (Actual)
First Posted
Study Record Updates
Last Update Posted (Actual)
Last Update Posted
Last Update Submitted That Met QC Criteria
Last Update Submitted That Met QC Criteria
Last Verified
Last Verified
More Information
Terms related to this study
Additional Relevant MeSH Terms
Other Study ID Numbers
Other Study ID Numbers
- EXCOR PMA Post Approval
Plan for Individual participant data (IPD)
Plan to Share Individual Participant Data (IPD)?
Drug and device information, study documents
Studies a U.S. FDA-regulated drug product
Studies a U.S. FDA-regulated device product
This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.