Contralateral Head Rotation on Internal Jugular Vein to Carotid Artery Distance and Overlap Ratio
The Effect of Contralateral Head Rotation on Internal Jugular Vein to Carotid Artery Distance and Overlap Ratio
Study Overview
Status
Status
Conditions
Conditions
Intervention / Treatment
Intervention / Treatment
Detailed Description
Study Type
Study Type
Enrollment (Actual)
Enrollment
Phase
Phase
- Not Applicable
Contacts and Locations
Study Locations
-
-
-
Jakarta, Indonesia, 10430
- Cipto Mangunkusumo Central National Hospital
-
-
Participation Criteria
Eligibility Criteria
Eligibility Criteria
Ages Eligible for Study
Accepts Healthy Volunteers
Genders Eligible for Study
Description
Inclusion Criteria:
- ASA score 1 and 2
- 18-60 years old
- no anatomical abnormality in neck
Exclusion Criteria:
- obese
- has history of previous central venous catheter cannulation
- limitation on contralateral head movement
Study Plan
How is the study designed?
Design Details
- Primary Purpose: SUPPORTIVE_CARE
- Allocation: NA
- Interventional Model: SINGLE_GROUP
- Masking: NONE
Number of Arms
Arms and Interventions
Participant Group / ArmParticipant Group / Arm |
Intervention / TreatmentIntervention / Treatment |
|---|---|
|
OTHER: Triangle of Sedillot identification using ultrasonography
USG probe placed upright at the top of triangle of Sedillot at cricoid level
|
Contralateral head rotation was done with protractor at angle 30°, 45°, and 60°.
The distance and overlap ratio of IJV and CA was calculated in each angle.
|
What is the study measuring?
Primary Outcome Measures
Primary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
IJV to CA distance at different contralateral rotation angle
Time Frame: 2 months
|
IJV to CA distance at different contralateral rotation angle (0°, 30°, 45°, 60°)
|
2 months
|
|
IJV to CA overlap ratio at different contralateral rotation angle
Time Frame: 2 months
|
IJV to CA overlap ratio at different contralateral rotation angle (0°, 30°, 45°, 60°)
|
2 months
|
Collaborators and Investigators
Sponsor
Sponsor
Publications and helpful links
General Publications
- Lieberman JA, Williams KA, Rosenberg AL. Optimal head rotation for internal jugular vein cannulation when relying on external landmarks. Anesth Analg. 2004 Oct;99(4):982-988. doi: 10.1213/01.ANE.0000132908.77111.CA.
- Troianos CA, Hartman GS, Glas KE, Skubas NJ, Eberhardt RT, Walker JD, Reeves ST; Councils on Intraoperative Echocardiography and Vascular Ultrasound of the American Society of Echocardiography. Guidelines for performing ultrasound guided vascular cannulation: recommendations of the American Society of Echocardiography and the Society of Cardiovascular Anesthesiologists. J Am Soc Echocardiogr. 2011 Dec;24(12):1291-318. doi: 10.1016/j.echo.2011.09.021. No abstract available.
- Brass P, Hellmich M, Kolodziej L, Schick G, Smith AF. Ultrasound guidance versus anatomical landmarks for subclavian or femoral vein catheterization. Cochrane Database Syst Rev. 2015 Jan 9;1(1):CD011447. doi: 10.1002/14651858.CD011447.
- Sibai AN, Loutfi E, Itani M, Baraka A. Ultrasound evaluation of the anatomical characteristics of the internal jugular vein and carotid artery--facilitation of internal jugular vein cannulation. Middle East J Anaesthesiol. 2008 Oct;19(6):1305-20.
- Saitoh T, Satoh H, Kumazawa A, Nobuhara M, Machii M, Tanaka T, Shiraki K, Saotome M, Urushida T, Katoh H, Hayashi H. Ultrasound analysis of the relationship between right internal jugular vein and common carotid artery in the left head-rotation and head-flexion position. Heart Vessels. 2013 Sep;28(5):620-5. doi: 10.1007/s00380-012-0283-0. Epub 2012 Sep 12.
- Troianos CA, Kuwik RJ, Pasqual JR, Lim AJ, Odasso DP. Internal jugular vein and carotid artery anatomic relation as determined by ultrasonography. Anesthesiology. 1996 Jul;85(1):43-8. doi: 10.1097/00000542-199607000-00007.
- Miki I, Murata S, Nakazawa K, Onozawa S, Mine T, Ueda T, Yamaguchi H, Yasui D, Takeda M, Kumita S. Anatomical relationship between the common carotid artery and the internal jugular vein during head rotation. Ultrasound. 2014 May;22(2):99-103. doi: 10.1177/1742271X14524571. Epub 2014 Feb 25.
- DeAngelis V, Denny J, Chyu D, Jan T, Lemaire A, Chiricolo A, Solina A. The Optimal Angle of Head Rotation for Internal Jugular Cannulation as Determined by Ultrasound Evaluation. J Cardiothorac Vasc Anesth. 2015 Oct;29(5):1257-60. doi: 10.1053/j.jvca.2015.02.007. Epub 2015 Feb 9.
- Shoja MM, Ardalan MR, Tubbs RS, Loukas M, Vahedinia S, Jabbary R, Jalilvand M, Shakeri A. The relationship between the internal jugular vein and common carotid artery in the carotid sheath: the effects of age, gender and side. Ann Anat. 2008;190(4):339-43. doi: 10.1016/j.aanat.2008.04.002. Epub 2008 May 27.
Study record dates
Study Major Dates
Study Start (ACTUAL)
Study Start
Primary Completion (ACTUAL)
Primary Completion
Study Completion (ACTUAL)
Study Completion
Study Registration Dates
First Submitted
First Submitted
First Submitted That Met QC Criteria
First Submitted That Met QC Criteria
First Posted (ACTUAL)
First Posted
Study Record Updates
Last Update Posted (ACTUAL)
Last Update Posted
Last Update Submitted That Met QC Criteria
Last Update Submitted That Met QC Criteria
Last Verified
Last Verified
More Information
Terms related to this study
Other Study ID Numbers
Other Study ID Numbers
- IndonesiaUAnes025
Plan for Individual participant data (IPD)
Plan to Share Individual Participant Data (IPD)?
Drug and device information, study documents
Studies a U.S. FDA-regulated drug product
Studies a U.S. FDA-regulated device product
This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.