Endorectal Three-dimensional Ultrasound in the Diagnosis of Cryptogenic Fistulas of the Rectum.
A Prospective Comparative Study to Improve Preoperative Ultrasound Diagnosis of Rectal Fistulas in the Formation of Topical Diagnosis Using B-mode and Three-dimensional Image Reconstruction.
Study Overview
Status
Status
Conditions
Conditions
Intervention / Treatment
Intervention / Treatment
Detailed Description
Study Type
Study Type
Enrollment (Anticipated)
Enrollment
Phase
Phase
- Not Applicable
Contacts and Locations
Study Contact
Study Contact
- Name: Larisa Orlova, Proff.
- Phone Number: +74991996686
- Email: lporlova2013@yandex.ru
Study Locations
-
-
-
Moscow, Russian Federation, 123423
- Recruiting
- State Sceintific Centtre of Coloproctology
-
-
Participation Criteria
Eligibility Criteria
Eligibility Criteria
Ages Eligible for Study
Accepts Healthy Volunteers
Genders Eligible for Study
Description
Inclusion Criteria:
- Patients diagnosed with "fistula of the rectum"
- Patients diagnosed with cryptogenic fistulas
- Patients who have signed informed consent
Exclusion Criteria:
- Patients with perianal complications of Crohn's disease
- Рatients with post-traumatic fistulas
- Рatients with fistulas, drain pararectal cysts
- Рatients with anal fissures, complicated by rectal fistula
- Рatients who refused to participate in the study of their own free will
Study Plan
How is the study designed?
Design Details
- Primary Purpose: Diagnostic
- Allocation: Non-Randomized
- Interventional Model: Parallel Assignment
- Masking: None (Open Label)
Number of Arms
Arms and Interventions
Participant Group / ArmParticipant Group / Arm |
Intervention / TreatmentIntervention / Treatment |
|---|---|
|
Active Comparator: Transrectal ultrasound in В-mode
|
A linear transrectal ultrasonic sensor with a frequency of 9 MHz is inserted into the rectum lumen to a depth of 10 cm from the edge of the anus.
In real time, the rectal wall and anatomical structures of the anal canal are evaluated using linear sections.
The localization of the internal fistula opening, the course of the fistula relative to the fibers of the external sphincter and the presence or absence of cellular and wall plug is determined.
|
|
Experimental: Transrectal ultrasound examination using three-di
|
A mechanical circular transrectal ultrasonic sensor with a frequency of 13 MHz is inserted into the rectum lumen to a depth of 10 cm from the edge of the anus.
Within 30 seconds with a scan interval of 2 mm with a length of 10 cm, a circular recording of the anatomical structures of the rectum, surrounding tissue and anal canal takes place, obtaining an array of images in the form of a cube.
The study was completed.
After, at a convenient time for the researcher is working with a three-dimensional array of images.
The resulting cube can be rotated 360 degrees in a circle of its axis, work with the sagittal, frontal and axial plane.
To obtain a more visual representation of the exact localization of the internal fistula orifice, the course of the fistula relative to the fibers of the outer sphincter and to design volumetric cellular and wall plug.
|
What is the study measuring?
Primary Outcome Measures
Primary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Sensitivity
Time Frame: 14 days
|
Sensitivity in the diagnosis of cryptogenic fistulas of the rectum
|
14 days
|
Collaborators and Investigators
Sponsor
Sponsor
Study record dates
Study Major Dates
Study Start (Actual)
Study Start
Primary Completion (Anticipated)
Primary Completion
Study Completion (Anticipated)
Study Completion
Study Registration Dates
First Submitted
First Submitted
First Submitted That Met QC Criteria
First Submitted That Met QC Criteria
First Posted (Actual)
First Posted
Study Record Updates
Last Update Posted (Actual)
Last Update Posted
Last Update Submitted That Met QC Criteria
Last Update Submitted That Met QC Criteria
Last Verified
Last Verified
More Information
Terms related to this study
Additional Relevant MeSH Terms
Other Study ID Numbers
Other Study ID Numbers
- 82
Drug and device information, study documents
Studies a U.S. FDA-regulated drug product
Studies a U.S. FDA-regulated device product
This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.