Facilitating Needle Alignment With Aiming Method
Aiming Method May Facilitate Needle Alignment in Ultrasound-guided Subclavian Vein Catheterization
Study Overview
Status
Status
Conditions
Conditions
Intervention / Treatment
Intervention / Treatment
Study Type
Study Type
Enrollment (Actual)
Enrollment
Phase
Phase
- Not Applicable
Contacts and Locations
Study Locations
-
-
-
Chongqing, China, 400042
- Daping Hospital
-
-
Participation Criteria
Eligibility Criteria
Eligibility Criteria
Ages Eligible for Study
Accepts Healthy Volunteers
Genders Eligible for Study
Description
Inclusion Criteria:
- 18 years to 70 years
- American Society of Anesthesiologists (ASA) Physical Status Ⅰ-Ⅲ
- Elective surgery patients requiring subclavian vein catheterization
Exclusion Criteria:
- Local anatomic abnormalities in subclavicular area
- Preexisting subclavian vein thrombosis or coagulation disorders
- Refusal of subclavian vein catheterization
Study Plan
How is the study designed?
Design Details
- Primary Purpose: Prevention
- Allocation: Randomized
- Interventional Model: Parallel Assignment
- Masking: Single
Number of Arms
Arms and Interventions
Participant Group / ArmParticipant Group / Arm |
Intervention / TreatmentIntervention / Treatment |
|---|---|
|
Active Comparator: landmark techniques
Subclavian vein catheterization is performed without the guidance of ultrasound.
The needle was inserted 1 cm inferior and 1 cm lateral to the junction of the middle and medial thirds of the clavicle (infraclavicular approach)
|
The patient is positioned in Tredelenburg with the arm abducted to 90°.
Venipuncture should occur 1 cm lateral to the curvature of the middle third of the clavicle with the needle pointing horizontally directed at the sternal notch.
If subclavian vein is missing at the first try, withdraw the needle and direct horizontally at the cricoid cartilage at the second try.
|
|
Experimental: ultrasound-guided with aiming method
Subclavian vein catheterization is performed with our newly proposed aiming method with the guidance of ultrasound.
|
Here we introduced a new freehand method, named as Aiming Method, which facilitated the alignment of injection needles with ultrasound beams.
During this aiming method, patient is still positioned in Tredelenburg with the arm abducted to 90° and no needle guidance will be used.
|
|
Experimental: ultrasound-guided plus needle guide techniques
Subclavian vein catheterization is performed under ultrasound guidance with in-plane technique.
|
Subclavian vein catheterization is performed under ultrasound guidance with in-plane technique.
The patient is positioned in Tredelenburg with the arm abducted to 90°.
During the needle insertion, the needle is secured in the needle guidance device which keeps the alignment of needle and ultrasonic beam.
|
What is the study measuring?
Primary Outcome Measures
Primary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Procedural time
Time Frame: 24 hours
|
the time from skin break to guide wire was positioned into the subclavian vein
|
24 hours
|
|
Number of skin breaks
Time Frame: 24 hours
|
number of skin punctures
|
24 hours
|
Secondary Outcome Measures
Secondary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
The incidence of arterial puncture
Time Frame: 24 hours
|
aspiration of arterial blood during needle insertion or local haematoma in ultrasound image
|
24 hours
|
|
The incidence of pneumothorax
Time Frame: 24 hours
|
aspiration of air during needle insertion, or thoracic ultrasonography, or chest radiography
|
24 hours
|
Collaborators and Investigators
Sponsor
Sponsor
Study record dates
Study Major Dates
Study Start (Actual)
Study Start
Primary Completion (Actual)
Primary Completion
Study Completion (Actual)
Study Completion
Study Registration Dates
First Submitted
First Submitted
First Submitted That Met QC Criteria
First Submitted That Met QC Criteria
First Posted (Actual)
First Posted
Study Record Updates
Last Update Posted (Actual)
Last Update Posted
Last Update Submitted That Met QC Criteria
Last Update Submitted That Met QC Criteria
Last Verified
Last Verified
More Information
Terms related to this study
Other Study ID Numbers
Other Study ID Numbers
- 2018(45)
Drug and device information, study documents
Studies a U.S. FDA-regulated drug product
Studies a U.S. FDA-regulated device product
This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.