Pacing in Left Ventricular Assist Device Recipients (Pace-VAD)
Work Intolerance in Left Ventricular Assist Device Recipients: Impact of Pacing
Implantation with left ventricular assist device (LVAD) in patients with end-stage heart failure (HF) leads to improvements in survival and quality of life, however, work capacity remains disappointingly low, at half of the expected value. Complex central and peripheral hallmarks of heart failure attribute to the continued work intolerance, to which heart rate may be a contributing factor.
The purpose of this study is to clarify the impact of heart rate (by means of pacing) on work capacity (measured as peak oxygen uptake) in LVAD recipients.
Study Overview
Status
Status
Conditions
Conditions
Intervention / Treatment
Intervention / Treatment
Detailed Description
While implantation with left ventricular assist devices (LVADs) in patients with end-stage heart failure (HF) improve survival and quality of life, work capacity remains at a disappointing 50% of the expected value.
Due to the worldwide (increasing) shortage of donor hearts, LVADs are increasingly used as destination therapy which makes it crucial for physicians to persistently identify opportunities to improve management, lower the adverse events and maximize the benefits of this treatment option.
In recent years it was found that upregulation of device pump speed improves the maximal work capacity of LVAD recipients with no side effects. More recently it was found that the patients' heart rate reserve also was of importance in this regard, however, the latter was shown in a retrospective study and needs to be confirmed in a prospective randomized double-blinded intervention study. As a large portion of LVAD recipients are already implanted with a pacing device (and suffer from chronotropic incompetence) such a study is possible to conduct by controlling their heart rate during exercise by pacing (ie randomized crossover design).
Study Type
Study Type
Enrollment (Anticipated)
Enrollment
Phase
Phase
- Not Applicable
Contacts and Locations
Study Contact
Study Contact
- Name: Finn Gustafsson, MD, PhD, DMSc.
- Phone Number: 34459743
- Email: FinnG@dadlnet.dk
Study Locations
-
-
DK
-
Copenhagen, DK, Denmark, 2100
- Recruiting
- Rigshospitalet
-
Contact:
- Finn Gustafsson, MD, PhD, DMSc
- Phone Number: 35459743
- Email: FinnG@dadlnet.dk
-
-
Participation Criteria
Eligibility Criteria
Eligibility Criteria
Ages Eligible for Study
Accepts Healthy Volunteers
Genders Eligible for Study
Description
Inclusion Criteria:
- Implanted with a left ventricular assist device
- Implanted with a pace-device ensuring the possibility of pacing
- Age > 18
Exclusion Criteria:
- Not able to undergo a peak oxygen uptake test
- No consent
Study Plan
How is the study designed?
Design Details
- Primary Purpose: SUPPORTIVE_CARE
- Allocation: RANDOMIZED
- Interventional Model: CROSSOVER
- Masking: DOUBLE
Number of Arms
Arms and Interventions
Participant Group / ArmParticipant Group / Arm |
Intervention / TreatmentIntervention / Treatment |
|---|---|
|
OTHER: Peak oxygen uptake test with pacing
|
Peak oxygen uptake test with paced heart rate
Other Names:
|
|
SHAM_COMPARATOR: Peak oxygen uptake test without pacing
Peak VO2 test without pacing
|
Peak oxygen uptake test without paced heart rate
Other Names:
|
What is the study measuring?
Primary Outcome Measures
Primary Outcome Measures
Outcome Measure |
Time Frame |
|---|---|
|
Peak oxygen uptake (pVO2)
Time Frame: 1 Day
|
1 Day
|
Secondary Outcome Measures
Secondary Outcome Measures
Outcome Measure |
Time Frame |
|---|---|
|
Heart rate
Time Frame: 1 Day
|
1 Day
|
Collaborators and Investigators
Sponsor
Sponsor
Study record dates
Study Major Dates
Study Start (ACTUAL)
Study Start
Primary Completion (ANTICIPATED)
Primary Completion
Study Completion (ANTICIPATED)
Study Completion
Study Registration Dates
First Submitted
First Submitted
First Submitted That Met QC Criteria
First Submitted That Met QC Criteria
First Posted (ACTUAL)
First Posted
Study Record Updates
Last Update Posted (ACTUAL)
Last Update Posted
Last Update Submitted That Met QC Criteria
Last Update Submitted That Met QC Criteria
Last Verified
Last Verified
More Information
Terms related to this study
Other Study ID Numbers
Other Study ID Numbers
- H-17029488
Drug and device information, study documents
Studies a U.S. FDA-regulated drug product
Studies a U.S. FDA-regulated device product
This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.
Clinical Trials on Heart Rate
-
NCT04179279Completed
-
NCT07477834CompletedSleep | Heart Rate | Respiratory Rate | Air Pollution Exposure | SpO2 | HRV | Resting Heart Rate
-
NCT03832205CompletedExercise | Heart Rate | Respiratory Rate
-
NCT03754231CompletedHeart Rate | Respiratory Rate | Vital Sign
-
NCT03750318Active, not recruitingHeart Rate | Respiratory Rate | Vital Sign
-
NCT07217327RecruitingDetection of Heart Rate and Respiratory Rate
-
NCT04151927CompletedHeart Rate Variability | Appetite | Resting Metabolic Rate
-
NCT05165381CompletedVital Signs Monitoring | Blood Pressure, Heart Rate, Respiratory Rate, Heart Rate Variability, Stress Index, Vital Signs Monitoring
-
NCT05889832CompletedHeart Rate Variability | Heart Rate | Respiratory Rate
Clinical Trials on Peak oxygen uptake test with pacing
-
NCT04732039RecruitingLeft Ventricular Failure, Unspecified
-
NCT01019538CompletedChronic Obstructive Pulmonary Disease
-
NCT03268915CompletedIdiopathic Pulmonary Fibrosis
-
NCT05337111CompletedOverweight and Obesity
-
NCT06384534CompletedPulmonary Arterial Hypertension | Chronic Thromboembolic Pulmonary Hypertension | Pulmonary Vascular Disorder
-
NCT06003244Active, not recruitingPulmonary Artery Hypertension | Chronic Thromboembolic Pulmonary Hypertension | Pulmonary Vascular Disease
-
NCT06385301CompletedLung Diseases, Obstructive | Lung Diseases, Interstitial | Lung Disease Chronic
-
NCT04197635CompletedHeart Failure With Reduced Ejection Fraction
-
NCT02300064CompletedChronic Obstructive Pulmonary Disease
-
NCT05063006CompletedLeft Ventricular Assist Device