Swan-Ganz Catheter Insertion (SG cath)
The Effect of Pause at the Right Ventricle on Success Rate of Final Placement in Swan-Ganz Catheterization
The goal of this prospective randomized controlled study is to investigate the effect of pause of advancement of the Swan-Ganz catheter, which is to check whether the Swan-Ganz catheter arrive exactly at the right ventricle or not, on success rate of final placement and required time in Swan-Ganz catheterization.
The question which the investigators are trying to answer is: Continuous advancement of Swan-Ganz catheter without intended pause in the right ventricle to check whether the Swan-Ganz catheter arrive exactly at the right ventricle will decrease the trial number and required time to success final placement of Swan-Ganz catheter?
Study Overview
Status
Status
Conditions
Conditions
Intervention / Treatment
Intervention / Treatment
Detailed Description
Many clinicians pause advancement of Swan-Ganz catheter to check whether the Swan-Ganz catheter arrive exactly at the right ventricle or not.
The hypothesis of this study is that the intended pause during advancement of Swan-Ganz catheter in the right ventricle induce failure in advancing of it into the pulmonary artery, and that it increase the required time for final placement of it into the pulmonary artery.
Study Type
Study Type
Enrollment (Anticipated)
Enrollment
Phase
Phase
- Not Applicable
Contacts and Locations
Study Contact
Study Contact
- Name: Jung-Man Lee, M.D.,PhD.
- Phone Number: +82-2-870-2513
- Email: jungman007@gmail.com
Study Locations
-
-
-
Seoul, Korea, Republic of, 07061
- Seoul National University Boramae Hospital
-
-
Participation Criteria
Eligibility Criteria
Eligibility Criteria
Ages Eligible for Study
Accepts Healthy Volunteers
Genders Eligible for Study
Description
Inclusion Criteria:
- The patients who need to Swan-Ganz catheterization for heart surgeries
Exclusion Criteria:
- Who doesn't agree to enroll
- Who has thrombus in the heart or the vena cavas.
Study Plan
How is the study designed?
Design Details
- Primary Purpose: Prevention
- Allocation: Randomized
- Interventional Model: Parallel Assignment
- Masking: Double
Number of Arms
Arms and Interventions
Participant Group / ArmParticipant Group / Arm |
Intervention / TreatmentIntervention / Treatment |
|---|---|
|
Active Comparator: with pause
When the practitioner or expert investigator recognize that the tip of Swan-Ganz catheter arrive in the right ventricle, the practitioner pause the advancement for 10 sec.
Next, the practitioner re-advance it to the pulmonary artery.
|
When the practitioner or expert investigator recognize that the tip of Swan-Ganz catheter arrive in the right ventricle, the practitioner pause the advancement for 10 sec.
Next, the practitioner re-advance it to the pulmonary artery.
|
|
Experimental: without pause
When the practitioner or expert investigator recognize that the tip of Swan-Ganz catheter arrive in the right ventricle, the practitioner advance it continuously without pause to the pulmonary artery.
|
When the practitioner or expert investigator recognize that the tip of Swan-Ganz catheter arrive in the right ventricle, the practitioner advance it continuously without pause to the pulmonary artery.
|
What is the study measuring?
Primary Outcome Measures
Primary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
trial number (n)
Time Frame: during Swan-Ganz catheterization procedure
|
trial number to success placement of Swan-Ganz catheter placement into the pulmonary artery.
|
during Swan-Ganz catheterization procedure
|
|
Success rate (%)
Time Frame: during Swan-Ganz catheterization procedure
|
Success rate in placement of Swan-Ganz catheter placement into the pulmonary artery
|
during Swan-Ganz catheterization procedure
|
|
required time (seconds)
Time Frame: during Swan-Ganz catheterization procedure
|
total time to success Swan-Ganz catheter placement into the pulmonary artery
|
during Swan-Ganz catheterization procedure
|
Secondary Outcome Measures
Secondary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
incidence of arrhythmia (n)
Time Frame: during Swan-Ganz catheterization procedure
|
incidence of arrhythmia due to Swan-Ganz catheterization
|
during Swan-Ganz catheterization procedure
|
|
direction of placement of Swan-Ganz catheter (n)
Time Frame: during Swan-Ganz catheterization procedure
|
direction of placement of Swan-Ganz catheter between the right pulmoary artery and the left pulmonary artery
|
during Swan-Ganz catheterization procedure
|
Collaborators and Investigators
Sponsor
Sponsor
Collaborators
Collaborators
Investigators
Investigators
- Principal Investigator: Jung-Man Lee, M.D.,PhD, SMG-SNU Boramae Medical Center
Study record dates
Study Major Dates
Study Start (Anticipated)
Study Start
Primary Completion (Anticipated)
Primary Completion
Study Completion (Anticipated)
Study Completion
Study Registration Dates
First Submitted
First Submitted
First Submitted That Met QC Criteria
First Submitted That Met QC Criteria
First Posted (Actual)
First Posted
Study Record Updates
Last Update Posted (Actual)
Last Update Posted
Last Update Submitted That Met QC Criteria
Last Update Submitted That Met QC Criteria
Last Verified
Last Verified
More Information
Terms related to this study
Keywords
Other Study ID Numbers
Other Study ID Numbers
- 10-2019-14
Drug and device information, study documents
Studies a U.S. FDA-regulated drug product
Studies a U.S. FDA-regulated device product
This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.