A Novel Myocardial Impedance Mapping System for Ablation of Post-infarction Ventricular Arrhytmias in Humans
Study Overview
Status
Status
Conditions
Conditions
Intervention / Treatment
Intervention / Treatment
Detailed Description
Study Type
Study Type
Enrollment (Anticipated)
Enrollment
Contacts and Locations
Study Contact
Study Contact
- Name: Juan Cinca Cuscullola, Professor
- Phone Number: +34935537058
- Email: jcinca@santpau.cat
Study Locations
-
-
-
Barcelona, Spain, 08026
- Recruiting
- Hospital de la Santa Creu i Sant Pau
-
-
Participation Criteria
Eligibility Criteria
Eligibility Criteria
Ages Eligible for Study
Accepts Healthy Volunteers
Genders Eligible for Study
Sampling Method
Study Population
Description
Inclusion Criteria:
- More than 18 yearts
- Chronic myocardial infarction
- Undergoing ventricular ablation of ventricular arrhythmias
Exclusion Criteria:
- patients with device not suitable for cardiac magnetic ressonance (CMR)
- pregnacy
Study Plan
How is the study designed?
Design Details
Number of groups / cohorts
Cohorts and Interventions
Group / CohortGroup / Cohort |
Intervention / TreatmentIntervention / Treatment |
|---|---|
|
CASE GROUP
patients with chronic infarction undergoing catheter ablation of ventricular arrhythmias
|
Patients will be submitted to mapping of both voltage and tissue impedance.
The accuracy of the two maps identifying the extent and transmurality of the infarction will be assesssed by gadolinium imaging.
Other Names:
|
What is the study measuring?
Primary Outcome Measures
Primary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Comparative detection of infarct scar by voltage mapping
Time Frame: 3 hours
|
Voltage will be measured at different sites of the infarct scar and healthy tissue.
|
3 hours
|
|
Comparative detection of infarct scar by impedance mapping
Time Frame: 3 hours
|
myocardial local impedance will be measured at different sites of the infarct scar and healthy tissue.
|
3 hours
|
|
Comparative detection of infarct scar by gadolinium enhanced MR imaging
Time Frame: 30 minutes
|
Intensity of gadolinium will be measured at different sites of the infarct scar and healthy tissue.
|
30 minutes
|
Collaborators and Investigators
Sponsor
Sponsor
Collaborators
Collaborators
Publications and helpful links
General Publications
- Amoros-Figueras G, Jorge E, Alonso-Martin C, Traver D, Ballesta M, Bragos R, Rosell-Ferrer J, Cinca J. Endocardial infarct scar recognition by myocardial electrical impedance is not influenced by changes in cardiac activation sequence. Heart Rhythm. 2018 Apr;15(4):589-596. doi: 10.1016/j.hrthm.2017.11.031. Epub 2017 Dec 27.
- Jorge E, Amoros-Figueras G, Garcia-Sanchez T, Bragos R, Rosell-Ferrer J, Cinca J. Early detection of acute transmural myocardial ischemia by the phasic systolic-diastolic changes of local tissue electrical impedance. Am J Physiol Heart Circ Physiol. 2016 Feb 1;310(3):H436-43. doi: 10.1152/ajpheart.00754.2015. Epub 2015 Nov 25.
- Amoros-Figueras G, Jorge E, Garcia-Sanchez T, Bragos R, Rosell-Ferrer J, Cinca J. Recognition of Fibrotic Infarct Density by the Pattern of Local Systolic-Diastolic Myocardial Electrical Impedance. Front Physiol. 2016 Aug 31;7:389. doi: 10.3389/fphys.2016.00389. eCollection 2016.
Study record dates
Study Major Dates
Study Start (ACTUAL)
Study Start
Primary Completion (ANTICIPATED)
Primary Completion
Study Completion (ANTICIPATED)
Study Completion
Study Registration Dates
First Submitted
First Submitted
First Submitted That Met QC Criteria
First Submitted That Met QC Criteria
First Posted (ACTUAL)
First Posted
Study Record Updates
Last Update Posted (ACTUAL)
Last Update Posted
Last Update Submitted That Met QC Criteria
Last Update Submitted That Met QC Criteria
Last Verified
Last Verified
More Information
Terms related to this study
Additional Relevant MeSH Terms
Other Study ID Numbers
Other Study ID Numbers
- IIBSP-IMS-2015-90
Plan for Individual participant data (IPD)
Plan to Share Individual Participant Data (IPD)?
Drug and device information, study documents
Studies a U.S. FDA-regulated drug product
Studies a U.S. FDA-regulated device product
This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.
Clinical Trials on Ventricular Arrythmia
-
NCT07541092Recruiting
-
NCT03972865CompletedRight Ventricular Dysfunction | Ventricular Arrythmia
-
NCT05791032CompletedVentricular Fibrillation | Ventricular Tachycardia | Ventricular Arrythmia
-
NCT05964660Recruiting
-
NCT06051994Not yet recruitingCardiomyopathies | Ventricular Tachycardia | Ventricular Arrythmia
-
NCT06830746Active, not recruitingHeart Failure | Ventricular Arrythmia
-
NCT03412240Unknown
-
NCT06063811Not yet recruitingVentricular Tachycardia | Ventricular Arrythmia | End-stage Heart Failure | LVAD (Left Ventricular Assist Device)
-
NCT04990089CompletedVentricular Tachycardia | Ventricular Arrythmia | Premature Ventricular Contraction
-
NCT04845607RecruitingCardiac Arrest | Ventricular Arrythmia
Clinical Trials on CardioZ multifrequency impedance recording system
-
NCT03079960Recruiting
-
NCT05796349CompletedHealthy | Cerebral Hemorrhage | Cerebral Edema | Cerebral Ischemia
-
NCT04946331Recruiting
-
NCT03087084Unknown
-
NCT00960843Completed
-
NCT05919160Enrolling by invitationParkinson Disease, Idiopathic
-
NCT07456644Not yet recruitingMagnetohydrodynamic Effect | Gradient-induced Voltages | ECG Signal Quality, Measured Inside the MRI Bore
-
NCT07137455Enrolling by invitationVentricular Arrhythmia
-
NCT02773680UnknownRespiratory Monitoring