Evaluation of Quality of Vision and Spectacle Independence With the AcrySof® Panoptix® Intraocular Lens

November 20, 2023 updated by: SightTrust Eye Institute

Evaluation of Quality of Vision and Spectacle Independence With Bilateral Implantation of the AcrySof® Panoptix® Intraocular Lens

This is a study to assess the spectacle independence and quality of vision of patients receiving the AcrySof® Panoptix® Intraocular lens (IOL) after uneventful cataract surgery.

Study Overview

Status

Completed

Conditions

Intervention / Treatment

Detailed Description

This study is a single-arm unmasked clinical evaluation study of spectacle independence after successful bilateral cataract surgery. Subjects will be assessed pre-operatively, operatively and at 1 day, 1 month and 3 months post-operatively. Clinical evaluations will include administration of a spectacle independence questionnaire, as well as measurement of bilateral visual acuity and manifest refraction.

Study Type

Observational

Enrollment (Actual)

30

Contacts and Locations

This section provides the contact details for those conducting the study, and information on where this study is being conducted.

Study Locations

    • Florida
      • Sunrise, Florida, United States, 33323
        • SightTrust Eye Institute

Participation Criteria

Researchers look for people who fit a certain description, called eligibility criteria. Some examples of these criteria are a person's general health condition or prior treatments.

Eligibility Criteria

Ages Eligible for Study

  • Adult
  • Older Adult

Accepts Healthy Volunteers

Yes

Sampling Method

Non-Probability Sample

Study Population

Subjects ≥40 years of age presenting for cataract surgery who are interested in reducing their dependence on spectacles at all distances, and who are appropriate candidates for multifocal lens implantation.

Description

Inclusion Criteria

Subjects are eligible for the study if they meet the following criteria:

Note: Ocular criteria must be met in both eyes.

  • Presenting for uncomplicated bilateral cataract surgery and have an interest in spectacle independence using a multifocal IOL or multifocal toric IOL option
  • Gender: Males and Females.
  • Age: 40 or older.
  • Willing and able to provide written informed consent for participation in the study.
  • Willing and able to comply with scheduled visits and other study procedures.
  • Have good ocular health, with no pathology that compromises visual acuity (outside of residual refractive error and cataract)
  • Have regular corneal astigmatism with a magnitude that can be treated with a non-toric IOL or a toric IOL in the approved ranged for the Panoptix lens.
  • Have 20/32 (0.2 logMAR) or better potential acuity in both eyes

Exclusion Criteria If any of the following exclusion criteria are applicable to the subject or either eye, the subject should not be enrolled in the study.

  • Irregular astigmatism (e.g. keratoconus)
  • Corneal pathology (e.g. scar, dystrophy, pterygium, severe dry eye)
  • Monocular status (e.g. amblyopia)
  • Previous radial keratotomy, corneal refractive surgery or other corneal surgery (e.g. corneal transplant, lamellar keratoplasty)
  • Previous anterior or posterior chamber surgery (e.g., vitrectomy, laser iridotomy)
  • Diabetic retinopathy
  • Macular pathology (e.g. age-related macular degeneration, epiretinal membrane)
  • History of retinal detachment
  • Subjects who have an acute or chronic disease or illness that would confound the results of this investigation (e.g., immunocompromised, connective tissue disease, clinically significant atopic disease, diabetes, and any other such disease or illness), that are known to affect postoperative visual acuity.
  • Participation in any investigational drug or device trial within the previous 30 days prior to the start date of this trial (or currently participating).

The principal investigator reserves the right to declare a patient ineligible or non-evaluable based on medical evidence that indicates they are unsuitable for the trial.

Pregnancy has a known effect on the stability of refractions and visual acuity. As such, subjects who become pregnant during the study will not be discontinued but their data may be excluded from analyses of effectiveness.

Study Plan

This section provides details of the study plan, including how the study is designed and what the study is measuring.

How is the study designed?

Design Details

  • Observational Models: Cohort
  • Time Perspectives: Prospective

Cohorts and Interventions

Group / Cohort
Intervention / Treatment
Panoptix
Patients bilaterally implanted with the Panoptix intraocular lens.
Alcon Acrysof(R) Panoptix(R) intraocular lens (IOL)

What is the study measuring?

Primary Outcome Measures

Outcome Measure
Measure Description
Time Frame
Number of Emmetropic Subjects Who Are Spectacle Independent
Time Frame: 3 months
Number of patients who have a 3-month postoperative manifest spherical equivalent refraction within 0.5 diopters (D) of plano, and ≤ 0.5 D of refractive cylinder (emmetropic subgroup) who never or rarely wear spectacles for distance, intermediate or near vision 3 months postop (based on the Patient-Reported Spectacle Independence Questionnaire (PRSIQ) - "a little of the time" or "none of the time").
3 months

Secondary Outcome Measures

Outcome Measure
Measure Description
Time Frame
Binocular Uncorrected Distance Visual Acuity
Time Frame: 3 months
Binocular logMAR uncorrected distance visual acuity
3 months
Binocular Uncorrected Intermediate Visual Acuity
Time Frame: 3 months
Binocular logMAR uncorrected intermediate visual acuity
3 months
Binocular Uncorrected Near Visual Acuity
Time Frame: 3 months
Binocular logMAR uncorrected near visual acuity
3 months
Binocular Corrected Distance Visual Acuity
Time Frame: 3 months
Binocular logMAR corrected distance visual acuity
3 months
Binocular Distance-corrected Intermediate Visual Acuity
Time Frame: 3 months
Binocular distance-corrected intermediate visual acuity in logMAR
3 months
Binocular Distance-corrected Near Visual Acuity
Time Frame: 3 months
Binocular logMAR distance-corrected near visual acuity
3 months
Spherical Equivalent Refraction
Time Frame: 3 months
Spherical equivalent refraction in diopters
3 months
Residual Refractive Cylinder
Time Frame: 3 months
Residual refractive cylinder in diopters
3 months
Quality of Vision Questionnaire
Time Frame: 3 months
Quality of Vision questionnaire results. This is a Rasch-scaled test with scores from 0-100, with lower being better.
3 months
Overall Spectacle Independence
Time Frame: 3 months
percent of all patients who never or rarely wear spectacles for distance, intermediate or near vision 3 months postop (based on the PRSIQ - "a little of the time" or "none of the time")
3 months

Collaborators and Investigators

This is where you will find people and organizations involved with this study.

Sponsor

Collaborators

Investigators

  • Principal Investigator: Andrew C Shatz, MD, SightTrust Eye Institute

Publications and helpful links

The person responsible for entering information about the study voluntarily provides these publications. These may be about anything related to the study.

Study record dates

These dates track the progress of study record and summary results submissions to ClinicalTrials.gov. Study records and reported results are reviewed by the National Library of Medicine (NLM) to make sure they meet specific quality control standards before being posted on the public website.

Study Major Dates

Study Start (Actual)

October 3, 2019

Primary Completion (Actual)

February 16, 2021

Study Completion (Actual)

February 16, 2021

Study Registration Dates

First Submitted

October 11, 2019

First Submitted That Met QC Criteria

October 11, 2019

First Posted (Actual)

October 14, 2019

Study Record Updates

Last Update Posted (Estimated)

November 22, 2023

Last Update Submitted That Met QC Criteria

November 20, 2023

Last Verified

August 1, 2021

More Information

Terms related to this study

Additional Relevant MeSH Terms

Other Study ID Numbers

  • AS-19-001

Plan for Individual participant data (IPD)

Plan to Share Individual Participant Data (IPD)?

UNDECIDED

IPD Plan Description

No current plans exist. If data are shared, they will be de-identified beforehand.

Drug and device information, study documents

Studies a U.S. FDA-regulated device product

Yes

product manufactured in and exported from the U.S.

Yes

This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.