Coil Assisted Flow Diversion Safety and Performance Study (CAFI)
Coil Assisted Flow Diversion: A Prospective, Single Arm, Multi-center Study to Assess the Safety and Performance of Neqstent in Adjunctive Therapy (CAFI Study)
Cerus Endovascular is sponsoring a prospective, single arm, multi-center study to document the safety and performance of Neqstent in adjunctive therapy.
The purpose of the study is to document safety and performance of the Neqstent in adjunctive therapy in treatment for patients with intracranial aneurysms (IA).
Study Overview
Status
Status
Conditions
Conditions
Intervention / Treatment
Intervention / Treatment
Detailed Description
Study Type
Study Type
Enrollment (Actual)
Enrollment
Phase
Phase
- Not Applicable
Contacts and Locations
Study Locations
-
-
-
Salzburg, Austria
- Christian Doppler Klinikum
-
-
-
-
Alberta
-
Edmonton, Alberta, Canada
- Alberta Health Sciences
-
-
-
-
-
Odense, Denmark, 5000
- Odense University Hospital
-
-
-
-
-
Hamburg, Germany
- UK Hamburg
-
Kiel, Germany
- UKSH Kiel
-
Munich, Germany, D-81377
- Klinikum der Universität München
-
-
-
-
-
Basel, Switzerland
- Inerespital Basel
-
-
Participation Criteria
Eligibility Criteria
Eligibility Criteria
Ages Eligible for Study
Accepts Healthy Volunteers
Description
Inclusion Criteria:
- Patient's indication for treatment of unruptured IAs according to the national/international guidelines.
- Age 18-80 years at screening
- Patients who are suitable for non-emergency endovascular embolization of saccular IAs
- IA located at a bifurcation in the anterior or posterior circulation with dimensions consistent with implant size selection guidelines included in the IFU
- Patient has the necessary mental capacity to participate and is willing and able to participate in the study for the duration of the study follow-up and is able to comply with study requirements
- Patient able to able to give their informed consent can be included in this study. This must be demonstrated by means of a personally signed and dated informed consent document indicating that the subject has been informed of and understood all pertinent aspects of the study.
Exclusion Criteria:
- Ruptured aneurysm
- Patient anatomy or physiology considered unsuitable for endovascular treatment
- Any patient anatomy, physiology, existing implants with failed aneurysm embolization that would interfere with the ability for Neqstent to seal at the neck of the aneurysm. (i.e., compacted coils in close proximity to the neck that prevent good apposition of the Neqstent to the wall of the aneurysm, stent and/or stent-like devices whose struts span the aneurysm neck to retain the coil mass that inhibit access and/or successful Neqstent seating at the aneurysm neck, and/or any aneurysm that has a failed device and confirmed thrombus-burden inside the aneurysm sac)
- Contraindication for arterial access
- Largest measured IA neck diameter >8 mm or <3 mm
- Target IA contains other devices/implants (e.g., coils) that will prevent complete expansion of Neqstent
- Known allergy to platinum, nickel or titanium
- Known allergy to contrast agents
- Contraindication to anticoagulants or platelet inhibitor medication
- Stenosis of the target IA's parent vessel >50%
- Anticoagulation medications such as warfarin that cannot be discontinued.
- Pregnant, breastfeeding or women of childbearing potential not on adequate birth control (only women with a highly effective method of contraception [oral contraception or intra-uterine device] or sterile women can be enrolled to the study)
- Acute / chronic renal failure (including dialysis); Creatinine > 2.00 mg/dl or > 182 μmol/L
- Myocardial Infarction, Stroke or TIA within the last 6 months
- Any other medical issue within the brain that precludes the device implantation such as brain surgery, radiation in the target area of intervention, acute traumatic craniocerebral injury, etc.
- Other medical conditions that cause an inability to comply with study requirements and/or that could increase the risk of neurovascular procedures or death within 2 years (e.g., liver failure, cancer, heart failure, chronic obstructive pulmonary disease, immunosuppression, neural disease, and hematologic disorders etc.)
- Participating in another study with investigational devices or drugs that would confound the effects of the study outcomes
- The presence of condition that may create unacceptable risk during the aneurysm embolization procedure
Study Plan
How is the study designed?
Design Details
- Primary Purpose: Treatment
- Allocation: N/A
- Interventional Model: Single Group Assignment
- Masking: None (Open Label)
What is the study measuring?
Primary Outcome Measures
Primary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
The Proportion of Subjects With Death of Any Non-accidental Cause or Any Major Disabling Stroke After Treatment or Major Disabling Stroke or Death Due to Neurological Cause.
Time Frame: From day 31 to 6 months after treatment
|
From day 31 to 6 months after treatment
|
|
|
The Proportion of Subjects With Complete Occlusion
Time Frame: 6 months
|
Success will be defined as complete occlusion demonstrated by a Grade 1 using the Raymond Roy Scale.
|
6 months
|
Collaborators and Investigators
Sponsor
Sponsor
Investigators
Investigators
- Principal Investigator: Thomas Liebig, MD, Klinikum der Universität München
Publications and helpful links
Helpful Links
Study record dates
Study Major Dates
Study Start (Actual)
Study Start
Primary Completion (Actual)
Primary Completion
Study Completion (Actual)
Study Completion
Study Registration Dates
First Submitted
First Submitted
First Submitted That Met QC Criteria
First Submitted That Met QC Criteria
First Posted (Actual)
First Posted
Study Record Updates
Last Update Posted (Actual)
Last Update Posted
Last Update Submitted That Met QC Criteria
Last Update Submitted That Met QC Criteria
Last Verified
Last Verified
More Information
Terms related to this study
Additional Relevant MeSH Terms
Other Study ID Numbers
Other Study ID Numbers
- DNQS428-01
Plan for Individual participant data (IPD)
Plan to Share Individual Participant Data (IPD)?
Drug and device information, study documents
Studies a U.S. FDA-regulated drug product
Studies a U.S. FDA-regulated device product
product manufactured in and exported from the U.S.
This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.