Correlation of Serum Lactate and Activity of Multiple Sclerosis
Study Overview
Status
Status
Conditions
Conditions
Intervention / Treatment
Intervention / Treatment
Detailed Description
Study Type
Study Type
Enrollment (Anticipated)
Enrollment
Contacts and Locations
Study Locations
-
-
Dakahlia
-
Mansoura, Dakahlia, Egypt, 35516
- Recruiting
- Mansoura University Hospital
-
-
Participation Criteria
Eligibility Criteria
Eligibility Criteria
Ages Eligible for Study
Accepts Healthy Volunteers
Genders Eligible for Study
Sampling Method
Study Population
Description
Inclusion Criteria:
-Patients with multiple sclerosis (RRMS,PPMS and SPMS)
Exclusion Criteria:
-Patients with any other medical conditions that may affect the serum lactate level
Study Plan
How is the study designed?
Design Details
Number of groups / cohorts
Cohorts and Interventions
Group / CohortGroup / Cohort |
Intervention / TreatmentIntervention / Treatment |
|---|---|
|
Patients group
50 multiple sclerosis patients
|
The brain MR imaging examinations were done by using a 3 tesla scanner (Acheiva; Philips Medical Systems, Best, Netherlands).
All patients were examined in the supine position using head coil.
Routine images (T2, T1, FLAIR) and double inversion recovery sequence (DIR) were done to all patients: repetition time (TR) _ 9583 sec, echo time (TE) _ 25 sec, inversion time (TI) _ 3400 sec, IR delay _ 325 sec, echo train length (ETL) _ 17, 50 contiguous axial slices, thickness _ 3 mm, matrix size 240× 142 mm2, field of view (FOV) 230× 184 mm2.
Magnetic Resonance (MR) spectroscopy is a noninvasive diagnostic test for measuring biochemical changes in the brain.While magnetic resonance imaging (MRI) identifies the anatomical location of a lesion, MR spectroscopy compares the chemical composition of normal brain tissue with abnormal brain tissue.
This test can also be used to detect tissue changes in stroke and epilepsy.
|
|
Control group
30 normal healthy control
|
The brain MR imaging examinations were done by using a 3 tesla scanner (Acheiva; Philips Medical Systems, Best, Netherlands).
All patients were examined in the supine position using head coil.
Routine images (T2, T1, FLAIR) and double inversion recovery sequence (DIR) were done to all patients: repetition time (TR) _ 9583 sec, echo time (TE) _ 25 sec, inversion time (TI) _ 3400 sec, IR delay _ 325 sec, echo train length (ETL) _ 17, 50 contiguous axial slices, thickness _ 3 mm, matrix size 240× 142 mm2, field of view (FOV) 230× 184 mm2.
Magnetic Resonance (MR) spectroscopy is a noninvasive diagnostic test for measuring biochemical changes in the brain.While magnetic resonance imaging (MRI) identifies the anatomical location of a lesion, MR spectroscopy compares the chemical composition of normal brain tissue with abnormal brain tissue.
This test can also be used to detect tissue changes in stroke and epilepsy.
|
What is the study measuring?
Primary Outcome Measures
Primary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Biochemical testing
Time Frame: 2 days
|
Plasma lactate was assayed according to Trinder method14 .
All assays were carried out with Bechman Coulter AU480 autoanalyzer (USA).
|
2 days
|
Collaborators and Investigators
Sponsor
Sponsor
Publications and helpful links
Study record dates
Study Major Dates
Study Start (ACTUAL)
Study Start
Primary Completion (ANTICIPATED)
Primary Completion
Study Completion (ANTICIPATED)
Study Completion
Study Registration Dates
First Submitted
First Submitted
First Submitted That Met QC Criteria
First Submitted That Met QC Criteria
First Posted (ACTUAL)
First Posted
Study Record Updates
Last Update Posted (ACTUAL)
Last Update Posted
Last Update Submitted That Met QC Criteria
Last Update Submitted That Met QC Criteria
Last Verified
Last Verified
More Information
Terms related to this study
Additional Relevant MeSH Terms
Other Study ID Numbers
Other Study ID Numbers
- Mansoura University H 10
Plan for Individual participant data (IPD)
Plan to Share Individual Participant Data (IPD)?
Drug and device information, study documents
Studies a U.S. FDA-regulated drug product
Studies a U.S. FDA-regulated device product
This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.