The Ablate-by-LAW Study
Feasibility and Efficacy of Tailoring Ablation Index to Left Atrial Wall Thickness During Atrial Fibrillation Ablation: The Ablate By-LAW Study
Study Overview
Status
Status
Conditions
Conditions
Intervention / Treatment
Intervention / Treatment
Study Type
Study Type
Enrollment (Actual)
Enrollment
Phase
Phase
- Not Applicable
Contacts and Locations
Study Contact
Study Contact
- Name: Antonio Berruezo, MD, PhD
- Phone Number: (+34) 932 290 62 51
- Email: antonio.berruezo@quironsalud.es
Study Contact Backup
- Name: Beatriz Jauregui, MD
- Phone Number: (+34) 932 290 62 51
- Email: beatriz.jauregui@quironsalud.es
Study Locations
-
-
-
Bad Oeynhausen, Germany
- Herz- und Diabeteszentrum Nordrhein-Westfalen
-
Leipzig, Germany
- Heart Center Leipzig University Hospital
-
-
-
-
-
Pisa, Italy
- Azienda Ospedaliero-Universitaria Pisana
-
-
-
-
-
Barcelona, Spain, 08022
- Teknon Medical Center
-
Cadiz, Spain
- Puerta del Mar University Hospital
-
-
Participation Criteria
Eligibility Criteria
Eligibility Criteria
Ages Eligible for Study
Accepts Healthy Volunteers
Description
Inclusion Criteria:
- Age > 18 years.
- Indication for paroxysmal atrial fibrillation ablation.
- Signed informed consent.
Exclusion Criteria:
- Age < 18 years.
- Pregnancy.
- Previous AF ablation procedure (REDO).
Study Plan
How is the study designed?
Design Details
- Primary Purpose: Treatment
- Allocation: N/A
- Interventional Model: Single Group Assignment
- Masking: None (Open Label)
Number of Arms
Arms and Interventions
Participant Group / ArmParticipant Group / Arm |
Intervention / TreatmentIntervention / Treatment |
|---|---|
|
Experimental: Personalized AF ablation using MDCT-derived LAWT
Pre-procedural MDCT images will be analysed in Teknon Medical Center (core-lab), using ADAS-3D™ (Galgo Medical, Barcelona, Spain) to obtain 3D atrial wall thickness maps that will be introduced into CARTO® navigation system (Biosense Webster, Diamond Bar, California, US).
PVI will be performed point-by-point, aiming to complete a RF circle around the PV ostia (nephroid shape) on the 3D geometry using a ThermoCool® SmartTouch® 3.5-mm irrigated tip contact force-sensing RF ablation catheter (Biosense Webster, Inc.).
AI targets will be defined by LAWT on the thickness color map, as follows: Thickness < 1 mm (red): 300; 1-2 mm (yellow): 350; 2-3 mm (green): 400; 3-4 mm (blue): 450; > 4 mm (purple): 500.
The recommended power settings to reach these AI values will be, in general, 35 W for the posterior wall and 40 W for the anterior wall.
Wherever local AWT is > 3 mm (green and blue colors), an increased RF power (50 W) will be permitted.
|
Atrial fibrillation (AF) ablation adapting the ablation index (AI) target in a point-by-point manner, according the local left atrial wall thickness (LAWT), as measured by multidetector cardiac tomography (MDCT)
|
What is the study measuring?
Primary Outcome Measures
Primary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Arrhythmia-free survival
Time Frame: 1 year
|
1-year atrial arrhythmia-free survival
|
1 year
|
Secondary Outcome Measures
Secondary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Acute procedural outcomes
Time Frame: 1 day
|
Procedure times
|
1 day
|
|
Peri-procedural complications
Time Frame: 1 month
|
1 month
|
|
|
REDO outcomes
Time Frame: 2 years
|
Mean LAWT at late reconnection sites
|
2 years
|
Collaborators and Investigators
Sponsor
Sponsor
Collaborators
Collaborators
Publications and helpful links
General Publications
- Kirchhof P, Benussi S, Kotecha D, Ahlsson A, Atar D, Casadei B, Castella M, Diener HC, Heidbuchel H, Hendriks J, Hindricks G, Manolis AS, Oldgren J, Alexandru Popescu B, Schotten U, Van Putte B, Vardas P. 2016 ESC Guidelines for the Management of Atrial Fibrillation Developed in Collaboration With EACTS. Rev Esp Cardiol (Engl Ed). 2017 Jan;70(1):50. doi: 10.1016/j.rec.2016.11.033. No abstract available. Erratum In: Rev Esp Cardiol (Engl Ed). 2017 Nov;70(11):1031. English, Spanish.
- Calkins H, Hindricks G, Cappato R, Kim YH, Saad EB, Aguinaga L, Akar JG, Badhwar V, Brugada J, Camm J, Chen PS, Chen SA, Chung MK, Nielsen JC, Curtis AB, Davies DW, Day JD, d'Avila A, de Groot NMSN, Di Biase L, Duytschaever M, Edgerton JR, Ellenbogen KA, Ellinor PT, Ernst S, Fenelon G, Gerstenfeld EP, Haines DE, Haissaguerre M, Helm RH, Hylek E, Jackman WM, Jalife J, Kalman JM, Kautzner J, Kottkamp H, Kuck KH, Kumagai K, Lee R, Lewalter T, Lindsay BD, Macle L, Mansour M, Marchlinski FE, Michaud GF, Nakagawa H, Natale A, Nattel S, Okumura K, Packer D, Pokushalov E, Reynolds MR, Sanders P, Scanavacca M, Schilling R, Tondo C, Tsao HM, Verma A, Wilber DJ, Yamane T. 2017 HRS/EHRA/ECAS/APHRS/SOLAECE expert consensus statement on catheter and surgical ablation of atrial fibrillation: Executive summary. J Arrhythm. 2017 Oct;33(5):369-409. doi: 10.1016/j.joa.2017.08.001. Epub 2017 Sep 15. No abstract available.
- Ouyang F, Tilz R, Chun J, Schmidt B, Wissner E, Zerm T, Neven K, Kokturk B, Konstantinidou M, Metzner A, Fuernkranz A, Kuck KH. Long-term results of catheter ablation in paroxysmal atrial fibrillation: lessons from a 5-year follow-up. Circulation. 2010 Dec 7;122(23):2368-77. doi: 10.1161/CIRCULATIONAHA.110.946806. Epub 2010 Nov 22.
- Cappato R, Negroni S, Pecora D, Bentivegna S, Lupo PP, Carolei A, Esposito C, Furlanello F, De Ambroggi L. Prospective assessment of late conduction recurrence across radiofrequency lesions producing electrical disconnection at the pulmonary vein ostium in patients with atrial fibrillation. Circulation. 2003 Sep 30;108(13):1599-604. doi: 10.1161/01.CIR.0000091081.19465.F1. Epub 2003 Sep 8.
- Kuck KH, Hoffmann BA, Ernst S, Wegscheider K, Treszl A, Metzner A, Eckardt L, Lewalter T, Breithardt G, Willems S; Gap-AF-AFNET 1 Investigators*. Impact of Complete Versus Incomplete Circumferential Lines Around the Pulmonary Veins During Catheter Ablation of Paroxysmal Atrial Fibrillation: Results From the Gap-Atrial Fibrillation-German Atrial Fibrillation Competence Network 1 Trial. Circ Arrhythm Electrophysiol. 2016 Jan;9(1):e003337. doi: 10.1161/CIRCEP.115.003337.
- Ikeda A, Nakagawa H, Lambert H, Shah DC, Fonck E, Yulzari A, Sharma T, Pitha JV, Lazzara R, Jackman WM. Relationship between catheter contact force and radiofrequency lesion size and incidence of steam pop in the beating canine heart: electrogram amplitude, impedance, and electrode temperature are poor predictors of electrode-tissue contact force and lesion size. Circ Arrhythm Electrophysiol. 2014 Dec;7(6):1174-80. doi: 10.1161/CIRCEP.113.001094. Epub 2014 Nov 7.
- Thiagalingam A, D'Avila A, Foley L, Guerrero JL, Lambert H, Leo G, Ruskin JN, Reddy VY. Importance of catheter contact force during irrigated radiofrequency ablation: evaluation in a porcine ex vivo model using a force-sensing catheter. J Cardiovasc Electrophysiol. 2010 Jul;21(7):806-11. doi: 10.1111/j.1540-8167.2009.01693.x. Epub 2010 Feb 1.
- Barkagan M, Rottmann M, Leshem E, Shen C, Buxton AE, Anter E. Effect of Baseline Impedance on Ablation Lesion Dimensions: A Multimodality Concept Validation From Physics to Clinical Experience. Circ Arrhythm Electrophysiol. 2018 Oct;11(10):e006690. doi: 10.1161/CIRCEP.118.006690.
- Reddy VY, Dukkipati SR, Neuzil P, Natale A, Albenque JP, Kautzner J, Shah D, Michaud G, Wharton M, Harari D, Mahapatra S, Lambert H, Mansour M. Randomized, Controlled Trial of the Safety and Effectiveness of a Contact Force-Sensing Irrigated Catheter for Ablation of Paroxysmal Atrial Fibrillation: Results of the TactiCath Contact Force Ablation Catheter Study for Atrial Fibrillation (TOCCASTAR) Study. Circulation. 2015 Sep 8;132(10):907-15. doi: 10.1161/CIRCULATIONAHA.114.014092. Epub 2015 Aug 10.
- Shah DC, Lambert H, Nakagawa H, Langenkamp A, Aeby N, Leo G. Area under the real-time contact force curve (force-time integral) predicts radiofrequency lesion size in an in vitro contractile model. J Cardiovasc Electrophysiol. 2010 Sep;21(9):1038-43. doi: 10.1111/j.1540-8167.2010.01750.x.
- De Potter T, Van Herendael H, Balasubramaniam R, Wright M, Agarwal SC, Sanders P, Khaykin Y, Latcu DG, Maury P, Pani A, Hayes J, Kalman J, Nery P, Duncan E. Safety and long-term effectiveness of paroxysmal atrial fibrillation ablation with a contact force-sensing catheter: real-world experience from a prospective, multicentre observational cohort registry. Europace. 2018 Nov 1;20(FI_3):f410-f418. doi: 10.1093/europace/eux290.
- Ho SY, Cabrera JA, Tran VH, Farre J, Anderson RH, Sanchez-Quintana D. Architecture of the pulmonary veins: relevance to radiofrequency ablation. Heart. 2001 Sep;86(3):265-70. doi: 10.1136/heart.86.3.265.
- Ho SY, Sanchez-Quintana D. The importance of atrial structure and fibers. Clin Anat. 2009 Jan;22(1):52-63. doi: 10.1002/ca.20634.
- Kistler PM, Ho SY, Rajappan K, Morper M, Harris S, Abrams D, Sporton SC, Schilling RJ. Electrophysiologic and anatomic characterization of sites resistant to electrical isolation during circumferential pulmonary vein ablation for atrial fibrillation: a prospective study. J Cardiovasc Electrophysiol. 2007 Dec;18(12):1282-8. doi: 10.1111/j.1540-8167.2007.00981.x. Epub 2007 Oct 3.
- Takahashi K, Okumura Y, Watanabe I, Nagashima K, Sonoda K, Sasaki N, Kogawa R, Iso K, Ohkubo K, Nakai T, Hirayama A. Relation Between Left Atrial Wall Thickness in Patients with Atrial Fibrillation and Intracardiac Electrogram Characteristics and ATP-Provoked Dormant Pulmonary Vein Conduction. J Cardiovasc Electrophysiol. 2015 Jun;26(6):597-605. doi: 10.1111/jce.12660. Epub 2015 May 1.
- Suenari K, Nakano Y, Hirai Y, Ogi H, Oda N, Makita Y, Ueda S, Kajihara K, Tokuyama T, Motoda C, Fujiwara M, Chayama K, Kihara Y. Left atrial thickness under the catheter ablation lines in patients with paroxysmal atrial fibrillation: insights from 64-slice multidetector computed tomography. Heart Vessels. 2013 May;28(3):360-8. doi: 10.1007/s00380-012-0253-6. Epub 2012 Apr 22.
- Nakamura K, Funabashi N, Uehara M, Ueda M, Murayama T, Takaoka H, Komuro I. Left atrial wall thickness in paroxysmal atrial fibrillation by multislice-CT is initial marker of structural remodeling and predictor of transition from paroxysmal to chronic form. Int J Cardiol. 2011 Apr 14;148(2):139-47. doi: 10.1016/j.ijcard.2009.10.032. Epub 2009 Nov 10.
- Chikata A, Kato T, Sakagami S, Kato C, Saeki T, Kawai K, Takashima S, Murai H, Usui S, Furusho H, Kaneko S, Takamura M. Optimal Force-Time Integral for Pulmonary Vein Isolation According to Anatomical Wall Thickness Under the Ablation Line. J Am Heart Assoc. 2016 Mar 15;5(3):e003155. doi: 10.1161/JAHA.115.003155.
- Sun JY, Yun CH, Mok GSP, Liu YH, Hung CL, Wu TH, Alaiti MA, Eck BL, Fares A, Bezerra HG. Left Atrium Wall-mapping Application for Wall Thickness Visualisation. Sci Rep. 2018 Mar 8;8(1):4169. doi: 10.1038/s41598-018-22089-z.
- Bishop M, Rajani R, Plank G, Gaddum N, Carr-White G, Wright M, O'Neill M, Niederer S. Three-dimensional atrial wall thickness maps to inform catheter ablation procedures for atrial fibrillation. Europace. 2016 Mar;18(3):376-83. doi: 10.1093/europace/euv073. Epub 2015 Apr 4.
- Schaeffer B, Willems S, Sultan A, Hoffmann BA, Luker J, Schreiber D, Akbulak R, Moser J, Kuklik P, Steven D. Loss of Pace Capture on the Ablation Line During Pulmonary Vein Isolation versus "Dormant Conduction": Is Adenosine Expendable? J Cardiovasc Electrophysiol. 2015 Oct;26(10):1075-80. doi: 10.1111/jce.12759. Epub 2015 Aug 29.
- Das M, Loveday JJ, Wynn GJ, Gomes S, Saeed Y, Bonnett LJ, Waktare JEP, Todd DM, Hall MCS, Snowdon RL, Modi S, Gupta D. Ablation index, a novel marker of ablation lesion quality: prediction of pulmonary vein reconnection at repeat electrophysiology study and regional differences in target values. Europace. 2017 May 1;19(5):775-783. doi: 10.1093/europace/euw105.
- Hussein A, Das M, Chaturvedi V, Asfour IK, Daryanani N, Morgan M, Ronayne C, Shaw M, Snowdon R, Gupta D. Prospective use of Ablation Index targets improves clinical outcomes following ablation for atrial fibrillation. J Cardiovasc Electrophysiol. 2017 Sep;28(9):1037-1047. doi: 10.1111/jce.13281. Epub 2017 Jul 26.
- Taghji P, El Haddad M, Phlips T, Wolf M, Knecht S, Vandekerckhove Y, Tavernier R, Nakagawa H, Duytschaever M. Evaluation of a Strategy Aiming to Enclose the Pulmonary Veins With Contiguous and Optimized Radiofrequency Lesions in Paroxysmal Atrial Fibrillation: A Pilot Study. JACC Clin Electrophysiol. 2018 Jan;4(1):99-108. doi: 10.1016/j.jacep.2017.06.023. Epub 2017 Sep 27.
- Inoue J, Skanes AC, Gula LJ, Drangova M. Effect of Left Atrial Wall Thickness on Radiofrequency Ablation Success. J Cardiovasc Electrophysiol. 2016 Nov;27(11):1298-1303. doi: 10.1111/jce.13065. Epub 2016 Sep 16.
- Pambrun T, Combes S, Sousa P, Bloa ML, El Bouazzaoui R, Grand-Larrieu D, Thompson N, Martin R, Combes N, Boveda S, Haissaguerre M, Albenque JP. Contact-force guided single-catheter approach for pulmonary vein isolation: Feasibility, outcomes, and cost-effectiveness. Heart Rhythm. 2017 Mar;14(3):331-338. doi: 10.1016/j.hrthm.2016.12.008. Epub 2016 Dec 7.
- Steven D, Reddy VY, Inada K, Roberts-Thomson KC, Seiler J, Stevenson WG, Michaud GF. Loss of pace capture on the ablation line: a new marker for complete radiofrequency lesions to achieve pulmonary vein isolation. Heart Rhythm. 2010 Mar;7(3):323-30. doi: 10.1016/j.hrthm.2009.11.011. Epub 2009 Nov 12.
- Eitel C, Hindricks G, Sommer P, Gaspar T, Kircher S, Wetzel U, Dagres N, Esato M, Bollmann A, Husser D, Hilbert S, Zaker-Shahrak R, Arya A, Piorkowski C. Circumferential pulmonary vein isolation and linear left atrial ablation as a single-catheter technique to achieve bidirectional conduction block: the pace-and-ablate approach. Heart Rhythm. 2010;7(2):157-64. doi: 10.1016/j.hrthm.2009.10.003. Epub 2009 Oct 12.
Study record dates
Study Major Dates
Study Start (Actual)
Study Start
Primary Completion (Actual)
Primary Completion
Study Completion (Actual)
Study Completion
Study Registration Dates
First Submitted
First Submitted
First Submitted That Met QC Criteria
First Submitted That Met QC Criteria
First Posted (Actual)
First Posted
Study Record Updates
Last Update Posted (Actual)
Last Update Posted
Last Update Submitted That Met QC Criteria
Last Update Submitted That Met QC Criteria
Last Verified
Last Verified
More Information
Terms related to this study
Keywords
Additional Relevant MeSH Terms
Other Study ID Numbers
Other Study ID Numbers
- Ablation-by-LAW
Plan for Individual participant data (IPD)
Plan to Share Individual Participant Data (IPD)?
Drug and device information, study documents
Studies a U.S. FDA-regulated drug product
Studies a U.S. FDA-regulated device product
This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.