Effectiveness and Safety of the Colonoscopy Assisted by Endocuff vs. Standard in the Colorectal Cancer Screening
Effectiveness And Safety Of The Colonoscopy Assisted By Endocuff Visio Vs. Standard Colonoscopy In The Colorectal Cancer Screening Program: Clinical Random, Prospective, Multicentric, Open And Parallel Groups
Study Overview
Status
Status
Conditions
Conditions
Intervention / Treatment
Intervention / Treatment
Detailed Description
The main objective of the colorectal cancer screening program (CRC) is the detection of the greatest number of precursor lesions of neoplasms as well as cancerous lesions established in the general population with an intermediate risk of presenting CRC. Within this program, colonoscopy is considered the diagnostic technique of choice due to its cost-effectiveness balance. However, it remains a technique that is not entirely perfect since the omission of injuries during the procedure constitutes the main reason for the appearance of interval cancers, with a clear correlation between the rate of detection of adenomas and their appearance.
The vast majority of CRC arise from precancerous polyps, of which there are two main types: conventional adenomas and serrated polyps. Conventional adenomas are the most frequent polyps being responsible for the majority of CRC through the adenoma-carcinoma sequence. It should be taken into account that about 15-30% of sporadic CRC develops from serrated polyps through the serrated pathway of carcinogenesis, which is different from the traditional adenoma-carcinoma sequence. Endoscopic detection of serrated polyps is difficult due to their indistinguishable edges and flat or sessile morphology. In addition, they tend to be located in the right colon, a place that can be more difficult to reach in colonoscopy and examine completely.
Therefore, the ultimate goal of CRC screening colonoscopy is to reduce the appearance of CRC, trying to maximize the detection of polyps and therefore the detection rate of adenomas. For this there are several technical factors of colonoscopy, preparation, imaging and external devices that try to achieve an increase in the rate of detection of adenomas.
ENDOCUFF VISION® (Norgine Pharmaceuticals Ltd) is a medical device that is fixed at the distal end of the endoscope, improving its insertion in the intestine thanks to the action it exerts by flattening the folds and stabilizing the device. Its use is related to greater accuracy in the detection of adenomas, since it increases the visibility of the mucosa and thus decreases the number of polyps that may go unnoticed, increasing the detection rate of adenomas between 10 and 16 percentage points, according with published literature .
Thus, the hypothesis of the present study is to demonstrate that ENDOCUFF VISION® increases the detection rate of adenomas thanks to the improved visibility produced by the retraction of the folds and stabilizing the colonoscope. Likewise, the impact of the use of ENDOCUFF VISION® on the average number of adenomas detected per patient (MAPP) as well as serrated adenomas (MASPP), the total time of the endoscopic procedure, cecal intubation and the safety of its use will be estimated.
Study Type
Study Type
Enrollment (Actual)
Enrollment
Phase
Phase
- Not Applicable
Contacts and Locations
Study Locations
-
-
Castellon
-
Castellón De La Plana, Castellon, Spain, 12002
- Hospital Provincial de Castellon
-
-
Participation Criteria
Eligibility Criteria
Eligibility Criteria
Ages Eligible for Study
Accepts Healthy Volunteers
Genders Eligible for Study
Description
Inclusion Criteria:
A) Patients between the ages of 50 and 70 referred for a colonoscopy within the colorectal cancer screening program.
B) With the ability to provide informed consent
Exclusion Criteria:
- History of inflammatory bowel disease
- History or suspected obstruction or intestinal pseudo-obstruction located in the colon
- History of colon cancer or polyposic syndromes
- History of colonic stenosis
- History of severe diverticular segments in some region of the colon
- Subjects unable to provide informed consent
- Subjects under treatment with clopidogrel, warfarin, acenocoumarol or other new generation anticoagulants that have not discontinued treatment in accordance with the provisions of these procedures
- Pregnants females
- Subjects who are going to undergo a therapeutic or surveillance endoscopy for follow-up of injuries diagnosed in previous procedures
- Subjects whose baseline status does not allow the completion of the questionnaires necessary for the evaluation of the study objectives.
- History of previous colonic surgery except for appendectomy
- Any medical, psychological, psychiatric, geographic or social problem that is important and uncontrolled that may interfere with the patient's participation in the study or that does not allow adequate follow-up and adherence to the protocol and evaluation of the study results.
Study Plan
How is the study designed?
Design Details
- Primary Purpose: Screening
- Allocation: Randomized
- Interventional Model: Parallel Assignment
- Masking: None (Open Label)
Number of Arms
Arms and Interventions
Participant Group / ArmParticipant Group / Arm |
Intervention / TreatmentIntervention / Treatment |
|---|---|
|
Experimental: Endocuff
Colonoscopy procedure with the use of endocuff
|
Colonoscopy procedure with the use of ENDOCUFF VISION
|
|
Active Comparator: Control
Standard Colonoscopy procedure
|
Colonoscopy procedure with the use of ENDOCUFF VISION
|
What is the study measuring?
Primary Outcome Measures
Primary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
polyps detection rate per patient
Time Frame: immediately after the procedure
|
Rate of polyps detected
|
immediately after the procedure
|
|
adenoma detection rate per patient
Time Frame: immediately after the procedure
|
Rate of Adenoma detected
|
immediately after the procedure
|
Secondary Outcome Measures
Secondary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
differences in the mean of adenomas detected by patient
Time Frame: immediately after the procedure
|
Assess whether there are differences in the mean of adenomas detected by patient comparing Endocuff Colonoscopy and Standard Colonoscopy.
|
immediately after the procedure
|
|
Serrated adenoma rate detected by patient
Time Frame: immediately after the procedure
|
Rate of serrated adenomas
|
immediately after the procedure
|
|
Cancer lesion detection rate comparing Endocuff Colonoscopy and Standard Colonoscopy.
Time Frame: immediately after the procedure
|
Rate of lessions
|
immediately after the procedure
|
|
Cecal intubation rate and time to reach the cecum
Time Frame: immediately after the procedure
|
Time in minutes of the intubation
|
immediately after the procedure
|
|
Total time of the procedure
Time Frame: immediately after the procedure
|
Total time of the procedure, from the insertion of the colonoscope to its extraction comparing Endocuff Colonoscopy and Standard Colonoscopy.
|
immediately after the procedure
|
|
Colonoscope withdrawal time from cecum
Time Frame: immediately after the procedure
|
Colonoscope withdrawal time from cecum in patients in whom no polyps were detected
|
immediately after the procedure
|
|
Demonstrate the non-inferiority of patient experience when comparing Endocuff Colonoscopy and Standard Colonoscopy
Time Frame: through study completion, an average of 3 months
|
Number of Participants With Procedure-Related Adverse Events Intra and post-procedure (evaluated with CTC AE v4) comparing Endocuff Colonoscopy and Standard Colonoscopy.
This will be calculated as a Rate of Intra and post-procedure complications.
|
through study completion, an average of 3 months
|
Collaborators and Investigators
Sponsor
Sponsor
Study record dates
Study Major Dates
Study Start (Actual)
Study Start
Primary Completion (Actual)
Primary Completion
Study Completion (Actual)
Study Completion
Study Registration Dates
First Submitted
First Submitted
First Submitted That Met QC Criteria
First Submitted That Met QC Criteria
First Posted (Actual)
First Posted
Study Record Updates
Last Update Posted (Actual)
Last Update Posted
Last Update Submitted That Met QC Criteria
Last Update Submitted That Met QC Criteria
Last Verified
Last Verified
More Information
Terms related to this study
Keywords
Additional Relevant MeSH Terms
Other Study ID Numbers
Other Study ID Numbers
- FCVHPC-2018-PS-01
Plan for Individual participant data (IPD)
Plan to Share Individual Participant Data (IPD)?
Drug and device information, study documents
Studies a U.S. FDA-regulated drug product
Studies a U.S. FDA-regulated device product
product manufactured in and exported from the U.S.
This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.