Tension Band Wiring Versus Cannulated Screws in Fixation of Medial Malleolus in Ankle Fracture
Tension Band Wiring Versus Cannulated Screws in Fixation of Medial Malleolus in Ankle Fracture: Randomized Comparative Study
Study Overview
Status
Status
Conditions
Conditions
Intervention / Treatment
Intervention / Treatment
Study Type
Study Type
Enrollment (Actual)
Enrollment
Phase
Phase
- Not Applicable
Contacts and Locations
Study Locations
-
-
-
Erbil, Iraq, 44001
- Sherwan Hamawandi
-
-
Participation Criteria
Eligibility Criteria
Eligibility Criteria
Ages Eligible for Study
Accepts Healthy Volunteers
Genders Eligible for Study
Description
Inclusion Criteria:
- Patients aged from 20-55 years.
- Isolated or bimalleolar ankle fractures.
- Closed fractures.
Exclusion Criteria:
- Patient with poor bone quality on x ray (radiological osteopenia, thinning of the cortices, loss of trabecular definitions and previous insufficiency fractures)
- Type D isolated medial malleolus, supination adduction (vertical malleolar) fractures.
- Comminuted fractures.
- Skeletally immature patients.
Study Plan
How is the study designed?
Design Details
- Primary Purpose: Treatment
- Allocation: Randomized
- Interventional Model: Parallel Assignment
- Masking: None (Open Label)
Number of Arms
Arms and Interventions
Participant Group / ArmParticipant Group / Arm |
Intervention / TreatmentIntervention / Treatment |
|---|---|
|
Active Comparator: Tension band wiring
This group was treated by k-wires fixation and tension band wiring
|
medial malleolus fracture fixed with tension band wiring): 2 k.wires (1.6 mm) are inserted perpendicular to the fracture site.
Again the position is checked under image intensification for the correct direction and length.
We drilled a 2.5mm hole with a protection sleeve, 2-3cm above the level of the horizontal joint line, aiming the drill bit slightly inferiorly to avoid screw pullout.
We inserted a 3.5mm unicortical screw about 30 mm in length (with or without washer), 2-3mm is left for the wire between the bone and screw head before full tightening.
A steel wire is constructed into a figure of eight between the screw the reduction k. wires, then twisted to achieve interfragmentary compression
|
|
Active Comparator: Cannulated screws
This group was treated by 2 cannulated screws
|
In group 2 (15 patients with medial malleolus fixed by 2 cannulated screws): Two guide wires (1.6mm) are inserted perpendicular to the fracture site, the appropriate length, proper insertion site including the distance from the articular surface is checked fluoroscopically .the
length is measured .drilling of the bone through the threaded guide wire with a cannulated drill bit (3.2mm).
A two 4.5mm partially threaded cannulated screws (with or two washers) are inserted through the guide to achieve Compression, the guide wires are then removed
|
What is the study measuring?
Primary Outcome Measures
Primary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Modified Olerund and Molander scoring system
Time Frame: The functional outcome was measured in all patient 12 months after surgery
|
Ankle functional outcome
|
The functional outcome was measured in all patient 12 months after surgery
|
Collaborators and Investigators
Sponsor
Sponsor
Study record dates
Study Major Dates
Study Start (Actual)
Study Start
Primary Completion (Actual)
Primary Completion
Study Completion (Actual)
Study Completion
Study Registration Dates
First Submitted
First Submitted
First Submitted That Met QC Criteria
First Submitted That Met QC Criteria
First Posted (Actual)
First Posted
Study Record Updates
Last Update Posted (Actual)
Last Update Posted
Last Update Submitted That Met QC Criteria
Last Update Submitted That Met QC Criteria
Last Verified
Last Verified
More Information
Terms related to this study
Additional Relevant MeSH Terms
Other Study ID Numbers
Other Study ID Numbers
- HMU-Sherwan7
Plan for Individual participant data (IPD)
Plan to Share Individual Participant Data (IPD)?
Drug and device information, study documents
Studies a U.S. FDA-regulated drug product
Studies a U.S. FDA-regulated device product
This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.