The Canada Lymph Node Score Project: A Crossover Trial (CLNS)
Improving Preoperative Lung Cancer Staging Through the Canada Lymph Node Project: A Pan-Canadian Multicentered Crossover Trial
Study Overview
Status
Status
Conditions
Conditions
Intervention / Treatment
Intervention / Treatment
Detailed Description
Study Type
Study Type
Enrollment (Actual)
Enrollment
Phase
Phase
- Phase 3
Contacts and Locations
Study Locations
-
-
Alberta
-
Edmonton, Alberta, Canada, T5H 3V9
- Royal Alexandra Hospital
-
-
Manitoba
-
Winnipeg, Manitoba, Canada, R3A 1R9
- Health Sciences Centre
-
-
Ontario
-
Hamilton, Ontario, Canada, L8N 4A6
- St. Joseph's Healthcare Hamilton
-
Hamilton, Ontario, Canada, L8S 4L8
- McMaster University
-
Toronto, Ontario, Canada, M5G 2C4
- Toronto General Hospital
-
-
Quebec
-
Montréal, Quebec, Canada, H2L 4M1
- CHUM Endoscopic Tracheo-bronchial and Oesophageal Center
-
Montréal, Quebec, Canada, H4A 3S9
- MUHC Interventional Pulmonology Department
-
-
Participation Criteria
Eligibility Criteria
Eligibility Criteria
Ages Eligible for Study
Accepts Healthy Volunteers
Genders Eligible for Study
Description
Inclusion Criteria:
- Age ≥ 18 years
- Both CT and PET scans completed prior to EBUS
- Suspected or confirmed NSCLC requiring mediastinal staging
- cN0-cN1 as indicated by CT and PET scans
Exclusion Criteria:
- Patients with cN0 disease AND peripheral tumors AND tumor < 2 cm in diameter, as they do not require mediastinal staging
- Evidence of cN2 disease or higher on CT and PET scans
Study Plan
How is the study designed?
Design Details
- Primary Purpose: DIAGNOSTIC
- Allocation: NON_RANDOMIZED
- Interventional Model: CROSSOVER
- Masking: NONE
Number of Arms
Arms and Interventions
Participant Group / ArmParticipant Group / Arm |
Intervention / TreatmentIntervention / Treatment |
|---|---|
|
EXPERIMENTAL: Selective Targeted Sampling
During patients' Endobronchial Ultrasound (EBUS) procedure, they will first undergo: Selective Targeted Sampling - endosonographic assessment of at least 3 mediastinal lymph node stations (4R, 4L, and 7) using the four criteria of the Canada Lymph Node Score (predictor of nodal disease during Endobronchial Ultrasound). Each lymph node will be assigned a CLNS ranging from 0 to 4. Triple Normal lymph nodes will be defined as those that appear normal on CT (diameter < 1 cm), AND normal on PET (SUV < 2.5), AND normal on EBUS (CLNS < 2). Lymph nodes that are found to be Triple Normal will be marked as "Not for Biopsy", whereas all other lymph nodes will be biopsied. |
Mediastinal lymph nodes are assessed with the CLNS, and only those appearing malignant with the score are biopsied.
Triple Normal lymph nodes (normal appearing on PET, CT and EBUS) are not biopsied.
Other Names:
|
|
ACTIVE_COMPARATOR: Systematic Sampling
Upon completion of Systematic Targeted Sampling, all patients will crossover and receive the standard of care: Systematic Sampling - all lymph nodes previously marked as "Not for Biopsy" will be biopsied. At the conclusion of the EBUS procedure, all nodal stations would have been sampled as is mandated by current guidelines. |
All examined mediastinal lymph nodes are biopsied, regardless of whether they appear normal during PET, CT and EBUS.
Other Names:
|
What is the study measuring?
Primary Outcome Measures
Primary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Non-Inferiority Margin between Selective Targeted Sampling and Systematic Sampling
Time Frame: 2 years
|
A margin of 5% or less would be considered satisfactory for STS to be deemed non-inferior to SS.
|
2 years
|
Secondary Outcome Measures
Secondary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Diagnostic Statistics (between staging methods)
Time Frame: 2 years
|
Sensitivity, specificity, negative predictive value and positive predictive value
|
2 years
|
|
Agreement (between staging methods)
Time Frame: 2 years
|
Based on Cohen's Kappa statistics
|
2 years
|
|
Inconclusive Biopsy Rate
Time Frame: 2 years
|
Percentage of lymph nodes with inconclusive pathology from biopsy
|
2 years
|
|
Diagnostic Yield (accuracy)
Time Frame: 2 years
|
Proportion of lymph nodes with a pathological diagnosis for both sampling methods
|
2 years
|
|
Difference in Procedure Length
Time Frame: 2 years
|
For each sampling method (in minutes)
|
2 years
|
|
Difference in Cost per Procedure
Time Frame: 2 years
|
For each sampling method (sum of dollar costs for EBUS procedure)
|
2 years
|
Collaborators and Investigators
Sponsor
Sponsor
Collaborators
Collaborators
Investigators
Investigators
- Principal Investigator: Waël C Hanna, MDCM, MBA, FRCSC, McMaster University
Study record dates
Study Major Dates
Study Start (ACTUAL)
Study Start
Primary Completion (ACTUAL)
Primary Completion
Study Completion (ACTUAL)
Study Completion
Study Registration Dates
First Submitted
First Submitted
First Submitted That Met QC Criteria
First Submitted That Met QC Criteria
First Posted (ACTUAL)
First Posted
Study Record Updates
Last Update Posted (ACTUAL)
Last Update Posted
Last Update Submitted That Met QC Criteria
Last Update Submitted That Met QC Criteria
Last Verified
Last Verified
More Information
Terms related to this study
Additional Relevant MeSH Terms
Other Study ID Numbers
Other Study ID Numbers
- clns_10696
Plan for Individual participant data (IPD)
Plan to Share Individual Participant Data (IPD)?
Drug and device information, study documents
Studies a U.S. FDA-regulated drug product
Studies a U.S. FDA-regulated device product
This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.