Cuff Pressure Regulation Apparatus for Tracheal Intubation in Children (CPRATIC-2)
A Cross-over Study to Compare Two Different Tracheal Cuff Pressure Monitoring Devices in a Pediatric Intensive Care Unit
Study Overview
Status
Status
Conditions
Conditions
Intervention / Treatment
Intervention / Treatment
Detailed Description
Study Type
Study Type
Enrollment (Actual)
Enrollment
Phase
Phase
- Not Applicable
Contacts and Locations
Study Locations
-
-
-
Paris, France, 75019
- Robert Debré Hospital
-
-
Participation Criteria
Eligibility Criteria
Eligibility Criteria
Ages Eligible for Study
Accepts Healthy Volunteers
Genders Eligible for Study
Description
Inclusion Criteria:
- Infants and children more than 2 days after birth at term and less than 5 years of age
- Patient intubated in the PICU with a cuffed endotracheal tube
- Predicted duration of mechanical ventilation > or = 24-hours
- Signed informed consent
Exclusion Criteria:
- Intubated with an uncuffed endotracheal tube
- Children admitted to the PICU with a previous tracheostomy
- Preterm children or infants less than 2 days post-term
- Patient under block neuromuscular treatment
- Patient enrolled in another trial that might influence this study results
Study Plan
How is the study designed?
Design Details
- Primary Purpose: Supportive Care
- Allocation: Randomized
- Interventional Model: Crossover Assignment
- Masking: Single
Number of Arms
Arms and Interventions
Participant Group / ArmParticipant Group / Arm |
Intervention / TreatmentIntervention / Treatment |
|---|---|
|
Experimental: electronic device followed by pneumatic device
Children receive continuous control of tracheal cuff pressure with the electronic device (VBM©) for 6-hours followed by continuous control of tracheal cuff pressure with the pneumatic device (Nosten©) for 6-hours.
|
Continuous control of tracheal cuff pressure using an electronic device (VBM©) for 6-hours followed by continuous control using a pneumatic device (Nosten©) for 6-hours.
|
|
Experimental: pneumatic device followed by electronic device
Children receive the reverse sequence (continuous control using the pneumatic device (Nosten©) for 6-hours followed by the electronic device (VBM©) for 6-hours
|
Continuous control using a pneumatic device (Nosten©) for 6-hours followed by 6-hours of continuous control using an electronic device (VBM©).
|
What is the study measuring?
Primary Outcome Measures
Primary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Percentage of time spend with over or under-inflation of the tracheal cuff
Time Frame: 12 hours
|
Continuous recording of cuff pressure will be performed during the two 12-hours periods (electronic and pneumatic devices).
The period was speared by a time of wash-out of 30 minutes
|
12 hours
|
Secondary Outcome Measures
Secondary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
The response time to a significant variation in cuff pressure
Time Frame: 12 hours
|
Continuous recording of cuff pressure will be performed during the two 12-hours periods (electronic and pneumatic devices).
Automated analysis of the response time in milliseconds to a change in cuff pressure of at least 15% above or below the target value
|
12 hours
|
Collaborators and Investigators
Sponsor
Sponsor
Investigators
Investigators
- Principal Investigator: Boris LACARRA, MD, Assistance Publique - Hôpitaux de Paris
- Study Director: Stephane DAUGER, MD PhD, Assistance Publique - Hôpitaux de Paris
Study record dates
Study Major Dates
Study Start (Actual)
Study Start
Primary Completion (Actual)
Primary Completion
Study Completion (Actual)
Study Completion
Study Registration Dates
First Submitted
First Submitted
First Submitted That Met QC Criteria
First Submitted That Met QC Criteria
First Posted (Actual)
First Posted
Study Record Updates
Last Update Posted (Actual)
Last Update Posted
Last Update Submitted That Met QC Criteria
Last Update Submitted That Met QC Criteria
Last Verified
Last Verified
More Information
Terms related to this study
Other Study ID Numbers
Other Study ID Numbers
- APHP190869
- IDRCB: 2019-A02246-51 (Other Identifier: ANSM)
Plan for Individual participant data (IPD)
Plan to Share Individual Participant Data (IPD)?
Drug and device information, study documents
Studies a U.S. FDA-regulated drug product
Studies a U.S. FDA-regulated device product
This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.
Clinical Trials on Cuff Overinflation
-
NCT02109003CompletedCuff Overinflation | Cuff Underinflation
-
NCT06924112Not yet recruitingRotator Cuff Tear | Rotator Cuff Repair | Rotator Cuff Injury
-
NCT07005063RecruitingRotator Cuff Tear | Rotator Cuff Rupture | Rotator Cuff Injury
-
NCT04681937Not yet recruitingRotator Cuff Tears | Partial Tear of Rotator Cuff
-
NCT01987973CompletedRotator Cuff Injury | Full Thickness Rotator Cuff Tear | Rotator Cuff Syndrome | Disorder of Rotator Cuff | Skin Graft (Allograft) (Autograft) Failure
-
NCT05906004RecruitingRotator Cuff Tear | Rotator Cuff Injuries | Rotator Cuff Tears | Rotator Cuff Tears of the Shoulder
-
NCT07587502CompletedRotator Cuff Tendinopathy | Rotator Cuff Syndrome
-
NCT06788327Not yet recruitingRotator Cuff Repair | Rotator Cuff Tears | Rotator Cuff Injury
-
NCT07017205Not yet recruitingMicroaspiration | Endotracheal Tube Cuff Pressure | Endotracheal Tube Cuff
-
NCT06016439Not yet recruitingRotator Cuff Tears | Rotator Cuff Syndrome
Clinical Trials on Electronic device (VBM©)
-
NCT06460441CompletedObstructive Sleep Apnea Hypopnea Syndrome
-
NCT02054416Unknown
-
NCT03636841Unknown
-
NCT03814902CompletedAutism Spectrum Disorder | Wandering Behavior
-
NCT05968365Completed
-
NCT04289714Completed
-
NCT02148302TerminatedVenous Insufficiency of Leg | Impaired Wound Healing | Diabetic Ulcers
-
NCT01728285CompletedAllergic Rhinitis | Grass Allergy
-
NCT03471754Terminated