Evaluation of the Safety and Performance of Magneto Microcatheter
Evaluation of the Safety and Performance of Magneto Microcatheter for Endovascular Thrombectomy in Patients With Acute Ischemic Stroke
Study Overview
Status
Status
Conditions
Conditions
Intervention / Treatment
Intervention / Treatment
Study Type
Study Type
Enrollment (Actual)
Enrollment
Phase
Phase
- Not Applicable
Contacts and Locations
Study Contact
Study Contact
- Name: Shelly Sharon
- Phone Number: 0765300768
- Email: shelly@magts.com
Participation Criteria
Eligibility Criteria
Eligibility Criteria
Ages Eligible for Study
Accepts Healthy Volunteers
Description
Inclusion Criteria:
- Clinical signs consistent with acute ischemic stroke
- Patient with Acute Ischemic Stroke within 24 hours from symptoms o
- Age 18-85 years old
- Consent process is completed per international and local regulations
Exclusion Criteria:
- Known use of cocaine or other vasoactive substance
- Known bleeding diathesis
- Any known hemorrhagic or coagulation deficiency.
- Current use of oral anticoagulants with International Normalized Ratio (INR) > 3;
- PTT (Partial Thromboplastin Time)>2 at screening
- Uncontrolled hypertension (Systolic blood pressure>185 or Diastolic blood pressure>110) refractory to pharmacological management
- Pregnant or lactating female
- CT scan or MRI with evidence of acute intracranial hemorrhage, ASPECT score<6, mass effect and/or intracranial tumor
- Angiographic evidence of either carotid dissection or vasculitis at the target site or any condition that may limit device access to the target site (i.e high grade stenosis) per the treating physician's discretion.
Study Plan
How is the study designed?
Design Details
- Primary Purpose: Treatment
- Allocation: N/A
- Interventional Model: Single Group Assignment
- Masking: None (Open Label)
Number of Arms
Arms and Interventions
Participant Group / ArmParticipant Group / Arm |
Intervention / TreatmentIntervention / Treatment |
|---|---|
|
Experimental: Magneto Microcatheter
|
All patients will be treated with Magneto Microcatheter
|
What is the study measuring?
Primary Outcome Measures
Primary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Evaluation of the safety of Magneto Microcatheter in the acute post procedure duration by assessing the incidence of device related Serious Adverse Events within 24 hours post procedure
Time Frame: 24 hours
|
Occurrence of device related Serious Adverse Events
|
24 hours
|
Secondary Outcome Measures
Secondary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Evaluation of the safety of Magneto Microcatheter by assessing the incidence of device related Serious Adverse Events within 90 days post procedure
Time Frame: 90 days
|
Occurrence of device related Serious Adverse Events
|
90 days
|
|
Evaluation of the performance of Magneto Microcatheter by assessing its ability to remove the clot and evaluating its ease of use
Time Frame: During Procedure
|
Assessment of device performance in clot removal (TICI scale to evaluate revascularization) and ease of use (questionnaire that will be completed by the treating physician post procedure)
|
During Procedure
|
Collaborators and Investigators
Sponsor
Sponsor
Investigators
Investigators
- Principal Investigator: Dr. Marzelik, Sheba medical center
- Principal Investigator: Dr.Amsalem, Shaare Zedek, Israel
Study record dates
Study Major Dates
Study Start (Actual)
Study Start
Primary Completion (Actual)
Primary Completion
Study Completion (Actual)
Study Completion
Study Registration Dates
First Submitted
First Submitted
First Submitted That Met QC Criteria
First Submitted That Met QC Criteria
First Posted (Actual)
First Posted
Study Record Updates
Last Update Posted (Actual)
Last Update Posted
Last Update Submitted That Met QC Criteria
Last Update Submitted That Met QC Criteria
Last Verified
Last Verified
More Information
Terms related to this study
Additional Relevant MeSH Terms
Other Study ID Numbers
Other Study ID Numbers
- C14-CLN002
Plan for Individual participant data (IPD)
Plan to Share Individual Participant Data (IPD)?
Drug and device information, study documents
Studies a U.S. FDA-regulated drug product
Studies a U.S. FDA-regulated device product
product manufactured in and exported from the U.S.
This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.