Transcatheter Aortic Valve Replacement for Failed Transcatheter Aortic Valve
Transcatheter Aortic Valve Replacement for Failed Transcatheter Aortic Valve. An International Registry
Patients with failed transcather aortic valve (stenotic, regurgitant, both) and indication to further transcatheter aortic valve replacement (TAVR).
The purpouse of this study is to evaluate the indication to a second TAVR, the selection criteria of the second transcatheter aortic valve, procedural and clinical outcomes.
The primary endpoint of the study is overall mortality and Cardiovascular mortality at 1 year
Study Overview
Status
Status
Conditions
Conditions
Intervention / Treatment
Intervention / Treatment
Study Type
Study Type
Enrollment (Actual)
Enrollment
Contacts and Locations
Study Locations
-
-
Milan
-
San Donato Milanese, Milan, Italy, 20097
- IRCCS Policlinico San Donato
-
-
Participation Criteria
Eligibility Criteria
Eligibility Criteria
Ages Eligible for Study
Accepts Healthy Volunteers
Sampling Method
Study Population
Description
Inclusion Criteria:
- Patients with failed transcather aortic valve (stenotic, regurgitant, both) and indication to further transcatheter aortic valve replacement (TAVR).
Exclusion Criteria:
-
Study Plan
How is the study designed?
Design Details
Number of groups / cohorts
Cohorts and Interventions
Group / CohortGroup / Cohort |
Intervention / TreatmentIntervention / Treatment |
|---|---|
|
failed transcather aortic valve (Stenotic)
|
Trancatheter aortic valve replacement
|
|
failed transcather aortic valve (Regurgitation)
|
Trancatheter aortic valve replacement
|
|
failed transcather aortic valve (Regurgitation and stenotic))
|
Trancatheter aortic valve replacement
|
What is the study measuring?
Primary Outcome Measures
Primary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Overall mortality
Time Frame: 1 year
|
Overall mortality and Cardiovascular mortality at 1 year
|
1 year
|
Secondary Outcome Measures
Secondary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
VARC-3 Events
Time Frame: 1 year
|
Cerebrovascular events, bleeding complications, periprocedural MI, conduction disturbances, BVF, procedural success, device success, AKI (all according to VARC-2).
|
1 year
|
Collaborators and Investigators
Sponsor
Sponsor
Publications and helpful links
General Publications
- Testa L, Casenghi M, Criscione E, Van Mieghem NM, Tchetche D, Asgar AW, De Backer O, Latib A, Reimers B, Stefanini G, Trani C, Giannini F, Bartorelli A, Wojakowski W, Dabrowski M, Jagielak D, Banning AP, Kharbanda R, Moreno R, Schofer J, Brinkmann C, van Royen N, Pinto D, Serra A, Segev A, Giordano A, Brambilla N, Agnifili M, Rubbio AP, Squillace M, Oreglia J, Tanja R, McCabe JM, Abizaid A, Voskuil M, Teles R, Zoccai GB, Sondergaard L, Bedogni F. Prosthesis-patient mismatch following transcatheter aortic valve replacement for degenerated transcatheter aortic valves: the TRANSIT-PPM international project. Front Cardiovasc Med. 2022 Jul 29;9:931207. doi: 10.3389/fcvm.2022.931207. eCollection 2022.
- Testa L, Agnifili M, Van Mieghem NM, Tchetche D, Asgar AW, De Backer O, Latib A, Reimers B, Stefanini G, Trani C, Colombo A, Giannini F, Bartorelli A, Wojakowski W, Dabrowski M, Jagielak D, Banning AP, Kharbanda R, Moreno R, Schofer J, van Royen N, Pinto D, Serra A, Segev A, Giordano A, Brambilla N, Popolo Rubbio A, Casenghi M, Oreglia J, De Marco F, Tanja R, McCabe JM, Abizaid A, Voskuil M, Teles R, Biondi Zoccai G, Bianchi G, Sondergaard L, Bedogni F. Transcatheter Aortic Valve Replacement for Degenerated Transcatheter Aortic Valves: The TRANSIT International Project. Circ Cardiovasc Interv. 2021 Jun;14(6):e010440. doi: 10.1161/CIRCINTERVENTIONS.120.010440. Epub 2021 Jun 7.
Study record dates
Study Major Dates
Study Start (Actual)
Study Start
Primary Completion (Actual)
Primary Completion
Study Completion (Actual)
Study Completion
Study Registration Dates
First Submitted
First Submitted
First Submitted That Met QC Criteria
First Submitted That Met QC Criteria
First Posted (Actual)
First Posted
Study Record Updates
Last Update Posted (Actual)
Last Update Posted
Last Update Submitted That Met QC Criteria
Last Update Submitted That Met QC Criteria
Last Verified
Last Verified
More Information
Terms related to this study
Other Study ID Numbers
Other Study ID Numbers
- TRANSIT
Plan for Individual participant data (IPD)
Plan to Share Individual Participant Data (IPD)?
Drug and device information, study documents
Studies a U.S. FDA-regulated drug product
Studies a U.S. FDA-regulated device product
product manufactured in and exported from the U.S.
This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.