"Evaluation of Static and Dynamic Postural Balance in Children With Thoracic Hyperkyphosis"
Study Overview
Status
Status
Conditions
Conditions
Detailed Description
Study Type
Study Type
Enrollment (Actual)
Enrollment
Contacts and Locations
Study Locations
-
-
-
Istanbul, Turkey
- Istanbul University-Cerrapaşa, Faculty of Health Sciences
-
-
Participation Criteria
Eligibility Criteria
Eligibility Criteria
Ages Eligible for Study
Accepts Healthy Volunteers
Genders Eligible for Study
Sampling Method
Study Population
Description
Inclusion Criteria:
- Thoracic kyphosis angle: ≥ 45˚ (Cobb)
- Age between 9-18 years
- Volunteering to participate in the study
- Not physiotherapy
- Not cest tretment
Exclusion Criteria:
- Spinal surgery history
- Vision and hearing impairment
- Difficulty in detecting commands given
- Lower extremity affect that may affect balance
- Systemic disorder associated with balance
- Neurological influence
- > 20˚ (Cobb) scoliosis deformity
Study Plan
How is the study designed?
Design Details
Number of groups / cohorts
Cohorts and Interventions
Group / CohortGroup / Cohort |
|---|
|
toracic hyperkyphosis
children with COBB angle ≥ 45˚
|
|
control
children with kyphosis index < 13 measured using the flexicurve ruler
|
What is the study measuring?
Primary Outcome Measures
Primary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Biodex Balance System
Time Frame: the cases were evaluated once.
|
Biodex Balance System is a valid instrument used to measure postural stability in static and dynamic conditions.
The stability platform allows for varying levels of difficulty of stability testing from level 1 (stabil) to level 12 (least stable).
A high score is indicative of a lot of movement and indicates poor balance.
In present study was assessed average Overall, AP, and ML stability scores under the following 4 position: right-leg static balance, left-leg static balance, bilateral static balance and bilateral dynamic balance at BBS level 8 (moderately unstable).
Each position was applied with eyes open and closed.
|
the cases were evaluated once.
|
Secondary Outcome Measures
Secondary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Visual Analog Scale
Time Frame: the cases were evaluated once.
|
Visual Analogue Scale will be use to assess pain.
The scale consists of a horizontal line between 0-100mm.
A value of 0 mm indicates "no pain" and a value of 100 mm indicates "the most severe".
The severity of the pain that the patients feel in the back and neck regions during rest, activity and at night will be evaluated numerically.
|
the cases were evaluated once.
|
|
"Hand-held" dynamometer
Time Frame: the cases were evaluated once.
|
Maximal isometric contraction was evaluated with "Hand-held" dynamometer (Lafeyette Instrument®, Lafayette, IN) using a standard protocol and recorded in kg / Newton.
In our study, strength of trunk flexion and extansion, upper-middle-lower trapesiuz, serratus anterior, latissimus dorsi, bilateral hip flexion, extansion, abduction, knee flexion, extansion and ankle plantarflexion, dorsiflexion were examined bilaterally.
|
the cases were evaluated once.
|
|
Range of Motion
Time Frame: the cases were evaluated once.
|
Goniometric measurement is an objectively used method in the evaluation of ROM in the clinic.
In our study, trunk flexion, extansion and lateral flexion were measured with goniometer.
|
the cases were evaluated once.
|
|
Triple-Hop Distance (THD) test
Time Frame: the cases were evaluated once.
|
Triple-Hop Distance test is considered to be a valid and reliable test in evaluating the functional status as it is easy to apply and does not require much time and equipment.
Participants performed 3 consecutive maximal hops forward on the right and left limb.
It was measured with tape the distance hopped from the starting line to the point where the heel struck the ground upon completing the third hop.
The maximum distance achieved during the 3 trials was recorded in centimeters and was used for analysis.
High scores indicate that the functional condition is good.
|
the cases were evaluated once.
|
|
20-m sprint test
Time Frame: the cases were evaluated once.
|
20-m sprint test is used to evaluate the maximum running time of the participants.
Maximal effort sprint was assessed from a stationary start.
Participants was instructed to stand with one foot right behind the starting line and to accelerate at maximum effort to the finish line.
The best value of 3 trials (minimal sprint time) with a 2 min rest between trials was used for further data analysis.
Time was taken with a stop watch.
|
the cases were evaluated once.
|
|
Physical Activity Questionnaire for Children
Time Frame: the cases were evaluated once.
|
The physical activity level of the participants wasevaluated with the Physical Activity Questionnaire for Children , which is frequently used in the clinic.
This questionnaire consists of 9 items in the 5-point Likert type that questions the physical activities performed in the last 7 days and how often these activities are performed.
A high score on the scale indicates that the physical activity level is high.
|
the cases were evaluated once.
|
|
Pediatric Quality of Life Inventory
Time Frame: the cases were evaluated once.
|
Pediatric Quality of Life Inventory is a quality-of-life scale with validity and reliability of 23 items, which are frequently used in research to question the quality of life in children and adolescents.
The higher the score obtained from the scale, the higher the quality of life increases.
|
the cases were evaluated once.
|
|
Functional reach test
Time Frame: the cases were evaluated once.
|
It measures the distance (using a tape at the level of the acromion) that an participants are able to reach forward and sides from a starting standing position with a fixed base of support without loss of balance.
In our study, the distance to the forward and sides of the cases was tested.
For each position were made 3 measurements and their average values were calculated.
High scores indicate that the functional balance is good.
|
the cases were evaluated once.
|
|
The occiput-wall distance
Time Frame: the cases were evaluated once.
|
The occiput-wall distance is a surrogate measure of kyphosis.The method has been verified for its reliability and validity.
Two rulers were used to quantify the outcomes: the first ruler was placed on the landmark (occiput), and the second ruler was used to measure a perpendicular distance from the first ruler (occiput) to the wall.
The measurement was repeated for three trials with a period of rest as needed between the trials, and the average distance over the three trials was used for the data analysis.
Higher values indicate an increase in kyphosis angle.
|
the cases were evaluated once.
|
|
muscle flexibility of pektoralis minor
Time Frame: the cases were evaluated once.
|
The patients were placed in the supine position with their forearms pronated on the side of the body, in this position the distance between the acromion and the bed was measured with a tape measure and the value was recorded in cm.
High values indicate muscle shortness.
|
the cases were evaluated once.
|
Collaborators and Investigators
Sponsor
Sponsor
Investigators
Investigators
- Principal Investigator: Nazlı Nacar, Istanbul University-Cerrapaşa, Faculty of Health Sciences
- Study Director: Ayşe Zengin Alpözgen, Istanbul University-Cerrapaşa, Faculty of Health Sciences
Study record dates
Study Major Dates
Study Start (ACTUAL)
Study Start
Primary Completion (ACTUAL)
Primary Completion
Study Completion (ACTUAL)
Study Completion
Study Registration Dates
First Submitted
First Submitted
First Submitted That Met QC Criteria
First Submitted That Met QC Criteria
First Posted (ACTUAL)
First Posted
Study Record Updates
Last Update Posted (ACTUAL)
Last Update Posted
Last Update Submitted That Met QC Criteria
Last Update Submitted That Met QC Criteria
Last Verified
Last Verified
More Information
Terms related to this study
Additional Relevant MeSH Terms
Other Study ID Numbers
Other Study ID Numbers
- Istanbul University Cerrahpasa (Other Identifier: Istanbul University Cerrahpasa)
Drug and device information, study documents
Studies a U.S. FDA-regulated drug product
Studies a U.S. FDA-regulated device product
This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.