A Retrospective Analysis of the Diagnostic Performance of 11C-choline PET/CT in Primary Hyperparathyroidism
A Retrospective Analysis of the Diagnostic Performance of 11C-choline PET/CT for Detection of Hyperfunctioning Parathyroid Glands After Prior Negative or Discordant Imaging in Primary Hyperparathyroidism
Study Overview
Status
Status
Conditions
Conditions
Intervention / Treatment
Intervention / Treatment
Study Type
Study Type
Enrollment (Actual)
Enrollment
Participation Criteria
Eligibility Criteria
Eligibility Criteria
Ages Eligible for Study
Accepts Healthy Volunteers
Sampling Method
Study Population
Description
Inclusion Criteria:
Patients eligible for inclusion were ≥18 years old, diagnosed with biochemically confirmed pHPT, underwent a MIBI-SPECT/CT and/or cUS with negative or discordant results, and underwent a 11C-choline PET/CT followed by parathyroidectomy.
Exclusion Criteria:
Patients were excluded if they were known to have a germline mutation predisposing for familial hypocalciuric hypercalcemia (FHH).
Study Plan
How is the study designed?
Design Details
Number of groups / cohorts
Cohorts and Interventions
Group / CohortGroup / Cohort |
Intervention / TreatmentIntervention / Treatment |
|---|---|
|
All enrolled subjects received an 11C-choline PET/CT prior to enrollment.
Patients with biochemically proven primary hyperparathyroidism who underwent parathyroid surgery after localization by means of 11C-choline PET/CT and negative or discordant first-line imaging
|
11C-choline PET/CT
|
What is the study measuring?
Primary Outcome Measures
Primary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Sensitivity of 11C-choline PET/CT
Time Frame: Until 6 months after parathyroid surgery
|
Per-lesion sensitivity of 11C-choline PET/CT for the detection of overactive parathyroid glands
|
Until 6 months after parathyroid surgery
|
|
Positive predictive value of 11C-choline PET/CT
Time Frame: Until 6 months after parathyroid surgery
|
Per-lesion positive predictive value of 11C-choline PET/CT for the detection of overactive parathyroid glands
|
Until 6 months after parathyroid surgery
|
|
Accuracy of 11C-choline PET/CT
Time Frame: Until 6 months after parathyroid surgery
|
Per-lesion accuracy of 11C-choline PET/CT for the detection of overactive parathyroid glands
|
Until 6 months after parathyroid surgery
|
Collaborators and Investigators
Sponsor
Sponsor
Investigators
Investigators
- Principal Investigator: Adrienne Brouwers, MD PhD, University Medical Center Groningen
Study record dates
Study Major Dates
Study Start (Actual)
Study Start
Primary Completion (Actual)
Primary Completion
Study Completion (Actual)
Study Completion
Study Registration Dates
First Submitted
First Submitted
First Submitted That Met QC Criteria
First Submitted That Met QC Criteria
First Posted (Actual)
First Posted
Study Record Updates
Last Update Posted (Actual)
Last Update Posted
Last Update Submitted That Met QC Criteria
Last Update Submitted That Met QC Criteria
Last Verified
Last Verified
More Information
Terms related to this study
Additional Relevant MeSH Terms
- Neoplasms by Histologic Type
- Neoplasms
- Neoplasms, Glandular and Epithelial
- Endocrine System Diseases
- Parathyroid Diseases
- Hyperparathyroidism
- Hyperparathyroidism, Primary
- Adenoma
- Molecular Mechanisms of Pharmacological Action
- Antimetabolites
- Gastrointestinal Agents
- Hypolipidemic Agents
- Lipid Regulating Agents
- Nootropic Agents
- Lipotropic Agents
- Choline
Other Study ID Numbers
Other Study ID Numbers
- 2018/658
Plan for Individual participant data (IPD)
Plan to Share Individual Participant Data (IPD)?
IPD Plan Description
Drug and device information, study documents
Studies a U.S. FDA-regulated drug product
Studies a U.S. FDA-regulated device product
This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.