The Performance of a Robot-assisted Minimally Invasive Direct Cochlear Access for Cochlear Implantation
Study Overview
Status
Status
Conditions
Conditions
Intervention / Treatment
Intervention / Treatment
Study Type
Study Type
Enrollment (Actual)
Enrollment
Phase
Phase
- Not Applicable
Contacts and Locations
Study Locations
-
-
-
Bern, Switzerland, 3010
- Inselspital, Bern University Hospital
-
-
Participation Criteria
Eligibility Criteria
Eligibility Criteria
Ages Eligible for Study
Accepts Healthy Volunteers
Genders Eligible for Study
Description
Inclusion Criteria:
- Subjects scheduled for CI surgery according to clinical routine
- Subjects who will receive a cochlear implant
- Signed and dated informed consent form
Exclusion Criteria:
- Lack of compliance with any inclusion criteria
- Age under 18 years
- Pregnancy
- Distance of the planned trajectory to the facial nerve is < 0.4 mm as per screening CT scan
- Distance of the planned trajectory to the chorda tympani is < 0.3 mm as per screening CT scan
- A safe inner ear access cannot be planned for preservation of RW membrane and cochlear structures
- Individuals where image guidance or robotic procedures are not indicated
Study Plan
How is the study designed?
Design Details
- Primary Purpose: Treatment
- Allocation: N/A
- Interventional Model: Single Group Assignment
- Masking: None (Open Label)
Number of Arms
Arms and Interventions
Participant Group / ArmParticipant Group / Arm |
Intervention / TreatmentIntervention / Treatment |
|---|---|
|
Experimental: RCI-BE-10
Robot assisted cochlear implant surgery.
|
Robotic system for otological procedures
Otological surgical planning software
|
What is the study measuring?
Primary Outcome Measures
Primary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Relative ratio of successful electrode array insertions through the drilled direct cochlear access with the HEARO procedure to the total HEARO procedures.
Time Frame: day 0
|
The primary outcome measure of this study is to explore the relative ratio of the successful electrode array insertions into the cochlea through the drilled direct cochlear access with the HEARO procedure to the total HEARO procedures.
Aborted or converted procedures count as procedure in which insertion through the direct cochlea access was not possible.
The results will be expressed in relative numbers and in percentage.
|
day 0
|
Secondary Outcome Measures
Secondary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Electrode array insertion outcome
Time Frame: day 0
|
The angular insertion depth (in degrees) will be evaluated.
|
day 0
|
|
Electrode array insertion outcome
Time Frame: day 0
|
The number of inserted electrode contacts will be evaluated.
|
day 0
|
|
Electrode array insertion outcome
Time Frame: day 0
|
The surgical outcome (categories: nominal, tip-fold over or scalar deviation) will be evaluated.
|
day 0
|
|
Insertion depth prediction accuracy
Time Frame: day 0
|
The insertion depth prediction accuracy as the difference between the estimated insertion depth of the electrode at the planning and the actual insertion depth.
|
day 0
|
|
Absolute angular accuracy of the drilled tunnel access
Time Frame: day 0
|
The absolute in-plane and out-plane accuracy of the drilled tunnel is measured as the angular deviation between the planned trajectory in-plane and out-plane angles and the actual drilled angles from the intra-op image.
|
day 0
|
|
Absolute lateral accuracy of the drilled tunnel at the facial recess
Time Frame: day 0
|
The absolute lateral accuracy of the drilled tunnel to the facial nerve and chorda tympani is measured as the difference between the planned trajectory and the actual drilled trajectory distance.
|
day 0
|
|
Absolute lateral accuracy of the drilled tunnel at the target
Time Frame: day 0
|
The absolute lateral accuracy of the drilled tunnel is measured as the distance between the planned target trajectory position and actual target of the drilled trajectory position.
|
day 0
|
|
Ratio of the round window membrane preservation during the inner ear access
Time Frame: day 0
|
The ratio of the visibility of round window membrane surface at the robotic inner ear access by visual inspection.
This will be assessed as subjective evaluation by the surgeon.
|
day 0
|
|
Timing of the HEARO procedure
Time Frame: day 0
|
The timing of the different steps of the HEARO procedure will be recorded.
|
day 0
|
Collaborators and Investigators
Sponsor
Sponsor
Investigators
Investigators
- Principal Investigator: Marco Caversaccio, Prof. Dr., University Hospital Bern (Inselspital)
Study record dates
Study Major Dates
Study Start (Actual)
Study Start
Primary Completion (Actual)
Primary Completion
Study Completion (Actual)
Study Completion
Study Registration Dates
First Submitted
First Submitted
First Submitted That Met QC Criteria
First Submitted That Met QC Criteria
First Posted (Actual)
First Posted
Study Record Updates
Last Update Posted (Actual)
Last Update Posted
Last Update Submitted That Met QC Criteria
Last Update Submitted That Met QC Criteria
Last Verified
Last Verified
More Information
Terms related to this study
Additional Relevant MeSH Terms
Other Study ID Numbers
Other Study ID Numbers
- RCI-NEXT
Plan for Individual participant data (IPD)
Plan to Share Individual Participant Data (IPD)?
Drug and device information, study documents
Studies a U.S. FDA-regulated drug product
Studies a U.S. FDA-regulated device product
This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.