Detailed Description
- Primary objective: to compare the screening performance of DW MRI versus mammography alone or combined mammography and ultrasonography in women with PHBC.
- Secondary objective: to compare the tumor and patient characteristics detected by DW MRI and combined mammography and ultrasonography in women with PHBC.
- This is a prospective, single center, observational cohort study.
- A total of 1694 women will be enrolled in this study.
- Two latest 3.0 T MRI scanners with dedicated 16- or 18-channel bilateral breast coil are used for DW MRI. For DW MRI screening, the high-resolution echo-planar imaging sequence is designed to have an in-plane resolution of 1.3 x 1.3 mm and a slice thickness of 3 mm. Three b values of 0, 800, and 1200 sec/mm2 are used and ADC maps are generated based on the b=0 and 800 sec/mm2 DW MRI data. The DW MRI images are reconstructed into single summation images with maximum-intensity projections (MIPs) in the sagittal and axial planes. In addition, T1-weighted imaging sequence is also obtained with in-plane resolution of 1.0 x 1.0 mm and a slice thickness of 1 mm.
- All patients with PHBC undergo digital two-dimensional mammography and physician-performed whole-breast ultrasonography on the same day. DW MRI and conventional imaging (mammography and ultrasonography) are alternatively scheduled at 6-month intervals and the order has been randomized.
- Mammography alone, combined mammography and ultrasonography, and DW MRI will be interpreted independently according to the Breast Imaging Reporting and Data System (BI-RADS) and likelihood of malignancy (Score range, 0%-100%) by trained radiologists. DW MRI interpretation guidelines to be used in this study are based on both qualitative and quantitative assessments. Radiologists are required to successfully complete a training case series of 100 DW MR studies prior to interpreting the DW MRI.
- A negative examination result is defined as a final assessment BI-RADS category of 1, 2, 3 and a positive examination result is defined as a final assessment BI-RADS category of 4 or 5.
- Biopsies of DW MRI-detected lesions are performed under ultrasonography guidance whenever possible or with MR guidance if there is no correlative ultrasonography finding. Pathology of core or surgical biopsy and 1 year follow up is the reference standard.
Study Type
Study Type
Enrollment (Estimated)
Enrollment
Contacts and Locations
Study Locations
-
-
-
Seoul, Korea, Republic of
- Seoul National University Hospital
-
-
Participation Criteria
Eligibility Criteria
Eligibility Criteria
Ages Eligible for Study
Accepts Healthy Volunteers
Sampling Method
Study Population
Description
Inclusion Criteria:
- Women over 25 years of age at the time of enrollment
- Women who underwent breast conservation therapy or mastectomy and at increased risk of an interval second breast cancer (Age <50 at first cancer diagnosis; Breast density BI-RADS category 3 and 4; First degree family history; First breast cancer was an interval cancer or symptomatic presentation; First breast cancer was grade 2, 3 or ER and PR negative)
Exclusion Criteria:
- Women with signs or symptoms of breast cancer
- Women who had bilateral mastectomy
4. Women who had known metastatic disease 5. Pregnant or lactating women 6. Women with claustrophobia or metallic foreign body
Study Plan
How is the study designed?
Design Details
What is the study measuring?
Primary Outcome Measures
Primary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Cancer detection rate (CDR)
Time Frame: Baseline to up to 1 year
|
Number of detected cancers (invasive cancer and DCIS) /1000 women
|
Baseline to up to 1 year
|
Secondary Outcome Measures
Secondary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Sensitivity
Time Frame: Baseline to up to 1 year
|
Number of positive examinations with a tissue diagnosis of cancer within 1 year/All examinations with tissue diagnosis of cancer within the same period
|
Baseline to up to 1 year
|
|
Specificity
Time Frame: Baseline to up to 1 year
|
Number of negative examinations without tissue diagnosis of cancer within 1 year/All examinations without tissue diagnosis of cancer within the same period
|
Baseline to up to 1 year
|
|
Recall rate
Time Frame: Baseline to up to 1 year
|
Percentage of women screened with recommendation for further imaging prior to next routine examination
|
Baseline to up to 1 year
|
|
Positive predictive value (PPV)
Time Frame: Baseline to up to 1 year
|
PPV1: True positive/True positive + False positive
|
Baseline to up to 1 year
|
|
Accuracy
Time Frame: Baseline to up to 1 year
|
Proportion of true positive results (both true positive and true negative) in the population -The area under the (receiver operating characteristic) curve (AUC) |
Baseline to up to 1 year
|
|
Interval cancer rate
Time Frame: Baseline to up to 1 year
|
Breast cancer diagnosed within 1 year of a negative screening result because of clinical symptoms/1000 women
|
Baseline to up to 1 year
|
|
Characteristics of detected cancers
Time Frame: Baseline to up to 1 year
|
Tumor size, type, grade, molecular subtype, and lymph node metastasis
|
Baseline to up to 1 year
|
|
Characteristics of women with DW-MRI detected cancer
Time Frame: Baseline to up to 1 year
|
Age, menopausal status, breast density, family history
|
Baseline to up to 1 year
|
Collaborators and Investigators
Sponsor
Sponsor
Investigators
Investigators
- Study Chair: Woo Kyung Moon, MD, PhD, Seoul National University Hosptial
Publications and helpful links
Study record dates
Study Major Dates
Study Start (Estimated)
Study Start
Primary Completion (Estimated)
Primary Completion
Study Completion (Estimated)
Study Completion
Study Registration Dates
First Submitted
First Submitted
First Submitted That Met QC Criteria
First Submitted That Met QC Criteria
First Posted (Actual)
First Posted
Study Record Updates
Last Update Posted (Actual)
Last Update Posted
Last Update Submitted That Met QC Criteria
Last Update Submitted That Met QC Criteria
Last Verified
Last Verified
More Information
Terms related to this study
Additional Relevant MeSH Terms
Other Study ID Numbers
Other Study ID Numbers
- Breast Cancer Screening
Drug and device information, study documents
Studies a U.S. FDA-regulated drug product
Studies a U.S. FDA-regulated device product
This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.