Ultrasound Guided Positioning of Central Venous Catheters
The current standard for (correct) position control of a central venous catheter (CVC) is X-ray control, which is associated with X-rays for the patient. In some clinics, radiological services are not offered "around the clock". Therefore, an alternative that is not burdensome for patients and is available on all sides would be desirable. The possibility of a sonographic CVC position control is to be investigated.
The correct position of a central venous catheter is important. Complications/failure must be detected early/immediately. In addition to the X-ray of the thorax, a position control by means of an ECG derivative (α-card derivative) is available for position control. The method is easy to perform, but an epicardial or an arterial position of the CVC cannot be detected without the use of additional imaging in case of doubt.
For the reasons mentioned above, sonography is a suitable method to show the inflow of injected 0.9% sodium chloride solution into the right atrium, which allows to conclude the correct position of the CVC.
Study Overview
Status
Status
Conditions
Conditions
Intervention / Treatment
Intervention / Treatment
Study Type
Study Type
Enrollment (Actual)
Enrollment
Phase
Phase
- Not Applicable
Contacts and Locations
Study Locations
-
-
-
Nidda, Germany, 63667
- Neurologische Klinik Bad Salzhausen
-
-
Participation Criteria
Eligibility Criteria
Eligibility Criteria
Ages Eligible for Study
Accepts Healthy Volunteers
Genders Eligible for Study
Description
Inclusion Criteria:
- elective insertion of a central venous catheter.
Exclusion Criteria:
- emergency insertion of a central venous catheter
Study Plan
How is the study designed?
Design Details
- Primary Purpose: DIAGNOSTIC
- Allocation: NA
- Interventional Model: SINGLE_GROUP
- Masking: NONE
Number of Arms
Arms and Interventions
Participant Group / ArmParticipant Group / Arm |
Intervention / TreatmentIntervention / Treatment |
|---|---|
|
OTHER: Ultrasound
|
Using ultrasound control, the central vein catheter is injected with saline solution and the time to detect the saline bolus in the ultrasound is measured.
|
What is the study measuring?
Primary Outcome Measures
Primary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
- correlation between the time of detection of the injected saline bolus and radiological position of the central venous catheter
Time Frame: up to 5 seconds
|
- ultrasound during injection of saline solution into a newly inserted central venous catheter
|
up to 5 seconds
|
Collaborators and Investigators
Sponsor
Sponsor
Collaborators
Collaborators
Publications and helpful links
General Publications
- Schummer W, Schummer C, Schelenz C, Brandes H, Stock U, Muller T, Leder U, Huttemann E. Central venous catheters--the inability of 'intra-atrial ECG' to prove adequate positioning. Br J Anaesth. 2004 Aug;93(2):193-8. doi: 10.1093/bja/aeh191. Epub 2004 Jun 25.
- Schummer W, Herrmann S, Schummer C, Funke F, Steenbeck J, Fuchs J, Uhlig T, Reinhart K. Intra-atrial ECG is not a reliable method for positioning left internal jugular vein catheters. Br J Anaesth. 2003 Oct;91(4):481-6. doi: 10.1093/bja/aeg208.
Study record dates
Study Major Dates
Study Start (ACTUAL)
Study Start
Primary Completion (ACTUAL)
Primary Completion
Study Completion (ACTUAL)
Study Completion
Study Registration Dates
First Submitted
First Submitted
First Submitted That Met QC Criteria
First Submitted That Met QC Criteria
First Posted (ACTUAL)
First Posted
Study Record Updates
Last Update Posted (ACTUAL)
Last Update Posted
Last Update Submitted That Met QC Criteria
Last Update Submitted That Met QC Criteria
Last Verified
Last Verified
More Information
Terms related to this study
Other Study ID Numbers
Other Study ID Numbers
- CVC061120
Plan for Individual participant data (IPD)
Plan to Share Individual Participant Data (IPD)?
Drug and device information, study documents
Studies a U.S. FDA-regulated drug product
Studies a U.S. FDA-regulated device product
This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.