Performance Evaluation of a 3D PSIR Sequence in MRI at 1.5T (ESPOIR1-5)
Performance Evaluation of a 3D PSIR Sequence in MRI at 1.5T in the Detection and Characterization of Spinal Cord Injuries in Patients With Multiple Sclerosis
Inclusion visit (D0):
- verification of inclusion and non-inclusion criteria
- information and collection of consent
- standard imaging protocol prescribed as part of the usual treatment: sagittal T1 and T2 slices after injection of contrast product (Gadolinium), o 3D STIR sequence.
- 3D PSIR sequence at the level of the cervical cord for the duration of the additional sequence is 10 minutes, for a total examination time of 45 minutes (instead of 35 minutes).
Study Overview
Status
Status
Conditions
Conditions
Intervention / Treatment
Intervention / Treatment
Study Type
Study Type
Enrollment (Actual)
Enrollment
Contacts and Locations
Study Contact
Study Contact
- Name: Augustin Lecler
- Phone Number: 0148036401
- Email: alecler@for.paris
Study Locations
-
-
-
Bordeaux, France, 33000
- CHU de Bordeaux
-
Clermont-ferrand, France, 63000
- CHU de Clermont-Ferrand
-
Lille, France, 59000
- CHU de Lille
-
Lyon, France, 69002
- CHU de Lyon
-
Paris, France, 75019
- Fondation Ophtalmologique Adolphe de Rothschild (FOR)
-
Paris, France, 75013
- Hopital Prive des Peupliers
-
-
Participation Criteria
Eligibility Criteria
Eligibility Criteria
Ages Eligible for Study
Accepts Healthy Volunteers
Sampling Method
Study Population
Description
Inclusion Criteria:
- Patient over 18 years old
- To benefit from a medullary exploration planned by MRI 1.5T as part of a first evaluation or a re-evaluation of inflammatory involvement of the nevrax
- Express consent to participate in the study
- Affiliate or beneficiary of a social security scheme
Exclusion Criteria:
- Patient benefiting from a legal protection measure
- Pregnant, parturient or breastfeeding woman
- Absolute or relative contraindication to MRI
Study Plan
How is the study designed?
Design Details
- Observational Models: Cohort
- Time Perspectives: Prospective
What is the study measuring?
Primary Outcome Measures
Primary Outcome Measures
Outcome Measure |
Time Frame |
|---|---|
|
Estimate the number of spinal cord injuries detected with the set of standard sequences (T1, T2 and STIR) that are not detected with the 3D PSIR sequence
Time Frame: 1 DAY
|
1 DAY
|
|
Estimate the number of active lesions taking the contrast after injection of gadolinium, with the 3D PSIR sequence which is not detected in the set of standard sequences (T1, T2 and STIR)
Time Frame: 1 day
|
1 day
|
|
Compare the diagnostic confidence expressed by the radiologist for the detection of spinal cord injuries with the 3D PSIR sequence compared to the set of standard sequences (T1, T2 and STIR)
Time Frame: 1 DAY
|
1 DAY
|
|
Describe the quality of the images in terms of artifacts for each of the sequences used (T1, T2, STIR and PSIR)
Time Frame: 1 DAY
|
1 DAY
|
|
Measure the signal-to-noise ratio of each of the sequences used (T1, T2, STIR and PSIR)
Time Frame: 1 DAY
|
1 DAY
|
|
Measure the inter-observer agreement on the number of lesions detected with the 3D PSIR sequence
Time Frame: 1 DAY
|
1 DAY
|
|
Measure the intra-observer agreement on the number of lesions detected with the 3D PSIR sequence
Time Frame: 1 DAY
|
1 DAY
|
Collaborators and Investigators
Sponsor
Sponsor
Study record dates
Study Major Dates
Study Start (Actual)
Study Start
Primary Completion (Actual)
Primary Completion
Study Completion (Actual)
Study Completion
Study Registration Dates
First Submitted
First Submitted
First Submitted That Met QC Criteria
First Submitted That Met QC Criteria
First Posted (Actual)
First Posted
Study Record Updates
Last Update Posted (Actual)
Last Update Posted
Last Update Submitted That Met QC Criteria
Last Update Submitted That Met QC Criteria
Last Verified
Last Verified
More Information
Terms related to this study
Additional Relevant MeSH Terms
Other Study ID Numbers
Other Study ID Numbers
- ALR_2020_40
Drug and device information, study documents
Studies a U.S. FDA-regulated drug product
Studies a U.S. FDA-regulated device product
This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.