Heparin-based Wet Suction Method in EUS Fine Needle Biopsy of Solid Pancreatic Mass
Comparison of Heparin-based Wet Suction Method With Dry Suction Method in EUS Fine Needle Biopsy of Solid Pancreatic Mass
Study Overview
Status
Status
Conditions
Conditions
Intervention / Treatment
Intervention / Treatment
Detailed Description
Background & aim Endoscopic ultrasound guided fine needle biopsy (EUS-FNB) is the main tool for tissue acquisition and pathological diagnosis of pancreatic solid mass because of its superior accuracy and lower complication rate compared to CT-guided biopsy. However, the tissue adequacy and diagnostic yield remained unsatisfactory for 2 reasons. First, the conventional dry suction technique (DST) often get small tissue and 3 or more needle passes (i.e. biopsies) are required to obtain enough specimen. Second, blood contamination of the acquired tissue interfered with microscopic examination. Investigator aim to develop a novel technique to improve tissue acquisition within a fewer needle passes and avoid blood contamination by using heparin-based modified wet suction (H-MWST).
Methods This study will be a randomized crossover clinical trial. Patients with pancreatic solid mass indicated for EUS FNB will be enrolled. EUS FNB will be done by one experienced endoscopists in National Cheng Kung University Hospital. Patients will be randomized in a 1:1 ratio to receive EUS FNB with either dry suction technique (DST) or H-MWST first for the initial 2 needle passes, and then crossover to another suction technique for a total of 4 needle passes. The obtained tissue of each needle pass will be sent separately and examined by a pathologist who is unaware of the procedure order. Procedure related complications will be recorded. The primary outcome will be the acquired tissue quality quantified comparison. The secondary outcome will be the overall diagnostic yield, the specimen adequacy, and complication rate by each suction technique.
Study Type
Study Type
Enrollment (Anticipated)
Enrollment
Phase
Phase
- Not Applicable
Contacts and Locations
Study Contact
Study Contact
- Name: MengYing Lin, M.D.
- Phone Number: 3283 886-6-2353535
- Email: mikepjy@hotmail.com
Study Contact Backup
- Name: Wei Lun Chang, Ph.D.
- Phone Number: 2681 886-6-2353535
- Email: changwl6@gmail.com
Study Locations
-
-
-
Tainan, Taiwan, 704
- Recruiting
- National Cheng Kung University Hospital
-
Contact:
- MengYing Lin
- Phone Number: 3283 886-6-2353535
- Email: mikepjy@hotmail.com
-
-
Participation Criteria
Eligibility Criteria
Eligibility Criteria
Ages Eligible for Study
Accepts Healthy Volunteers
Genders Eligible for Study
Description
Inclusion Criteria:
- Patients had pancreatic solid mass on CT scan or abdominal echo image
Exclusion Criteria:
- Anti-platelet and anticoagulant user who cannot stop the medication
- Recent acute pancreatitis episode (within 2 weeks)
- Patient with severe cardio-pulmonary dysfunction
- Pregnant women and adolescent < 20 years old
Study Plan
How is the study designed?
Design Details
- Primary Purpose: Diagnostic
- Allocation: Randomized
- Interventional Model: Crossover Assignment
- Masking: Single
Number of Arms
Arms and Interventions
Participant Group / ArmParticipant Group / Arm |
Intervention / TreatmentIntervention / Treatment |
|---|---|
|
Experimental: Heparin Wet first group
Heparin based wet suction method of EUS FNB will go first for 2 passes and then shift to dry suction method for another 2 passes.
|
EUS FNB with Heparin wet suction: Investigator will remove stylet from the FNB device and then infuse Heparin 1ml (5000IU) into device before procedure. The syringe will pre-loaded with 10 ml negative pressure and attach to device upon needle tip insertion into mass lesion. EUS FNB with Dry suction: Investigator will remove stylet from the FNB device. Syringe will be pre-loaded with 10 ml negative pressure in syringe and attach to needle tail upon needle tip inserted into target lesion.
Other Names:
|
|
Experimental: Dry suction first group
Dry suction method of EUS FNB will go first for 2 passes and then shift to heparin base wet suction method for another 2 passes.
|
EUS FNB with Heparin wet suction: Investigator will remove stylet from the FNB device and then infuse Heparin 1ml (5000IU) into device before procedure. The syringe will pre-loaded with 10 ml negative pressure and attach to device upon needle tip insertion into mass lesion. EUS FNB with Dry suction: Investigator will remove stylet from the FNB device. Syringe will be pre-loaded with 10 ml negative pressure in syringe and attach to needle tail upon needle tip inserted into target lesion.
Other Names:
|
What is the study measuring?
Primary Outcome Measures
Primary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Quantification of tissue quality
Time Frame: 48 weeks
|
White tissue core length will be assessed immediately after procedure.
The acquired tumor tissue area and contaminant blood clot percentage will be assessed after total recruitment by single pathologist
|
48 weeks
|
Secondary Outcome Measures
Secondary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Needle pass number needed to establish diagnosis
Time Frame: 48 weeks
|
After 5 working days of histology slide preparation and pathologist interpretation.
Investigator can get the result
|
48 weeks
|
|
Diagnostic performance between different suction method
Time Frame: 48 weeks
|
After 5 working days of histology slide preparation and pathologist interpretation.
Investigator can get the result
|
48 weeks
|
Other Outcome Measures
Other Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Complication
Time Frame: 54 weeks
|
Investigator will keep follow up patient during admission course and 3 months after procedure to determine if presented with complications
|
54 weeks
|
Collaborators and Investigators
Sponsor
Sponsor
Investigators
Investigators
- Study Director: Bor-Shyang Sheu, Professor, National Cheng-Kung University Hospital
Publications and helpful links
General Publications
- Attam R, Arain MA, Bloechl SJ, Trikudanathan G, Munigala S, Bakman Y, Singh M, Wallace T, Henderson JB, Catalano MF, Guda NM. "Wet suction technique (WEST)": a novel way to enhance the quality of EUS-FNA aspirate. Results of a prospective, single-blind, randomized, controlled trial using a 22-gauge needle for EUS-FNA of solid lesions. Gastrointest Endosc. 2015;81(6):1401-7. doi: 10.1016/j.gie.2014.11.023. Epub 2015 Feb 27.
- Diehl DL, Mok SRS, Khara HS, Johal AS, Kirchner HL, Lin F. Heparin priming of EUS-FNA needles does not adversely affect tissue cytology or immunohistochemical staining. Endosc Int Open. 2018 Mar;6(3):E356-E362. doi: 10.1055/s-0043-121880. Epub 2018 Mar 7.
- Kasugai H, Yamamoto R, Tatsuta M, Okano Y, Okuda S, Kishigami Y, Kitamura T, Wada A, Tamura H. Value of heparinized fine-needle aspiration biopsy in liver malignancy. AJR Am J Roentgenol. 1985 Feb;144(2):243-4. doi: 10.2214/ajr.144.2.243.
- Mok SRS, Diehl DL, Johal AS, Khara HS, Confer BD, Mudireddy PR, Kirchner HL, Chen ZE. A prospective pilot comparison of wet and dry heparinized suction for EUS-guided liver biopsy (with videos). Gastrointest Endosc. 2018 Dec;88(6):919-925. doi: 10.1016/j.gie.2018.07.036. Epub 2018 Aug 16.
- Lin MY, Wu CL, Su YY, Huang CJ, Chang WL, Sheu BS. Tissue Quality Comparison Between Heparinized Wet Suction and Dry Suction in Endoscopic Ultrasound-Fine Needle Biopsy of Solid Pancreatic Masses: A Randomized Crossover Study. Gut Liver. 2022 Sep 2. doi: 10.5009/gnl220030. Online ahead of print.
Study record dates
Study Major Dates
Study Start (Actual)
Study Start
Primary Completion (Anticipated)
Primary Completion
Study Completion (Anticipated)
Study Completion
Study Registration Dates
First Submitted
First Submitted
First Submitted That Met QC Criteria
First Submitted That Met QC Criteria
First Posted (Actual)
First Posted
Study Record Updates
Last Update Posted (Actual)
Last Update Posted
Last Update Submitted That Met QC Criteria
Last Update Submitted That Met QC Criteria
Last Verified
Last Verified
More Information
Terms related to this study
Additional Relevant MeSH Terms
Other Study ID Numbers
Other Study ID Numbers
- NationalCheng-KungU (Registry Identifier: National Cheng-Kung University Hospital Clinical Trial Center)
Plan for Individual participant data (IPD)
Plan to Share Individual Participant Data (IPD)?
Drug and device information, study documents
Studies a U.S. FDA-regulated drug product
Studies a U.S. FDA-regulated device product
This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.