The Investigation of Mechanical Properties in Obesity.
The Affect of Obesity to Muscle Tone and Viscoelastic Properties
Study Overview
Status
Status
Conditions
Conditions
Intervention / Treatment
Intervention / Treatment
Detailed Description
Study Type
Study Type
Enrollment (Actual)
Enrollment
Phase
Phase
- Not Applicable
Contacts and Locations
Study Locations
-
-
-
Gaziantep, Turkey, 27144
- Hasan Kalyoncu University
-
-
Participation Criteria
Eligibility Criteria
Eligibility Criteria
Ages Eligible for Study
Accepts Healthy Volunteers
Genders Eligible for Study
Description
Inclusion Criteria:
- Body mass index (range; 18 - 35 kg/meter square)
Exclusion Criteria:
- Had any systemic or metabolic disease, psychological illness, or drug use,
- Had any disease that may cause muscle disease or muscle atrophy,
- musculoskeletal surgery for the last 3 months
Study Plan
How is the study designed?
Design Details
- Primary Purpose: Diagnostic
- Allocation: Randomized
- Interventional Model: Parallel Assignment
- Masking: Double
Number of Arms
Arms and Interventions
Participant Group / ArmParticipant Group / Arm |
Intervention / TreatmentIntervention / Treatment |
|---|---|
|
Experimental: Normal
Body mass index must to be in range limits (18.5-24.9
kg/meter square)
|
MyotonPro device is vertically placed on the muscle, a probe (3 mm diameter) creates constant pre-excitations (0.18 N) and generates short-term (15 ms), low-force (0.4 N) mechanical stimulations.These stimulations induce damped natural oscillations in the tissue and the device records these oscillations using an accelerometer.
Muscle tone, elasticity, and stiffness are calculated separately by the device
|
|
Experimental: Overweight
Body mass index must to be in range limits (25-29.9
kg/meter square)
|
MyotonPro device is vertically placed on the muscle, a probe (3 mm diameter) creates constant pre-excitations (0.18 N) and generates short-term (15 ms), low-force (0.4 N) mechanical stimulations.These stimulations induce damped natural oscillations in the tissue and the device records these oscillations using an accelerometer.
Muscle tone, elasticity, and stiffness are calculated separately by the device
|
|
Experimental: Obese
Body mass index must to be in range limits (30-34.9
kg/meter square)
|
MyotonPro device is vertically placed on the muscle, a probe (3 mm diameter) creates constant pre-excitations (0.18 N) and generates short-term (15 ms), low-force (0.4 N) mechanical stimulations.These stimulations induce damped natural oscillations in the tissue and the device records these oscillations using an accelerometer.
Muscle tone, elasticity, and stiffness are calculated separately by the device
|
What is the study measuring?
Primary Outcome Measures
Primary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Stiffness obtained from myotonometric assessment
Time Frame: Baseline
|
Myoton device stimulations create natural oscillations in the tissue and records these oscillations using an accelerometer.
Stiffness (N/m) is calculated by device
|
Baseline
|
|
Tone obtained from myotonometric assessment
Time Frame: Baseline
|
Myoton device stimulations create natural oscillations in the tissue and records these oscillations using an accelerometer.
Tone (Hz) is calculated by device
|
Baseline
|
|
Elasticity obtained from myotonometric assessment
Time Frame: Baseline
|
Myoton device stimulations create natural oscillations in the tissue and records these oscillations using an accelerometer.
Elasticity (log) is calculated by device.
|
Baseline
|
Collaborators and Investigators
Sponsor
Sponsor
Investigators
Investigators
- Principal Investigator: Serkan Usgu, HKU
Publications and helpful links
General Publications
- Mechelli F, Arendt-Nielsen L, Stokes M, Agyapong-Badu S. Validity of Ultrasound Imaging Versus Magnetic Resonance Imaging for Measuring Anterior Thigh Muscle, Subcutaneous Fat, and Fascia Thickness. Methods Protoc. 2019 Jul 10;2(3):58. doi: 10.3390/mps2030058.
- Wood S, Pearsall DJ, Ross R, Reid JG. Trunk muscle parameters determined from MRI for lean to obese males. Clin Biomech (Bristol, Avon). 1996 Apr;11(3):139-144. doi: 10.1016/0268-0033(95)00018-6.
- Tas S, Yilmaz S, Onur MR, Soylu AR, Altuntas O, Korkusuz F. Patellar tendon mechanical properties change with gender, body mass index and quadriceps femoris muscle strength. Acta Orthop Traumatol Turc. 2017 Jan;51(1):54-59. doi: 10.1016/j.aott.2016.12.003. Epub 2016 Dec 20.
- Kocur P, Tomczak M, Wiernicka M, Goliwas M, Lewandowski J, Lochynski D. Relationship between age, BMI, head posture and superficial neck muscle stiffness and elasticity in adult women. Sci Rep. 2019 Jun 11;9(1):8515. doi: 10.1038/s41598-019-44837-5.
- Kuo WH, Jian DW, Wang TG, Wang YC. Neck muscle stiffness quantified by sonoelastography is correlated with body mass index and chronic neck pain symptoms. Ultrasound Med Biol. 2013 Aug;39(8):1356-61. doi: 10.1016/j.ultrasmedbio.2012.11.015. Epub 2013 May 15.
- Faria A, Gabriel R, Abrantes J, Bras R, Moreira H. Triceps-surae musculotendinous stiffness: relative differences between obese and non-obese postmenopausal women. Clin Biomech (Bristol, Avon). 2009 Dec;24(10):866-71. doi: 10.1016/j.clinbiomech.2009.07.015. Epub 2009 Aug 22.
Study record dates
Study Major Dates
Study Start (Actual)
Study Start
Primary Completion (Actual)
Primary Completion
Study Completion (Actual)
Study Completion
Study Registration Dates
First Submitted
First Submitted
First Submitted That Met QC Criteria
First Submitted That Met QC Criteria
First Posted (Actual)
First Posted
Study Record Updates
Last Update Posted (Actual)
Last Update Posted
Last Update Submitted That Met QC Criteria
Last Update Submitted That Met QC Criteria
Last Verified
Last Verified
More Information
Terms related to this study
Keywords
Additional Relevant MeSH Terms
Other Study ID Numbers
Other Study ID Numbers
- 2020/101
Plan for Individual participant data (IPD)
Plan to Share Individual Participant Data (IPD)?
Drug and device information, study documents
Studies a U.S. FDA-regulated drug product
Studies a U.S. FDA-regulated device product
This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.