Real World Use and Outcomes of VASCADE Closure Device Versus Manual Compression in Patients With CFA Disease (VASCADE)
Real World Use and Outcomes of VASCADE Closure Device Versus Manual Compression in Patients With Common Femoral Artery Disease: A Retrospective Comparison Study
Study Overview
Status
Status
Conditions
Conditions
Detailed Description
The overall objective of the study will be to examine the safety and efficacy of the VASCADE closure device compared to manual compression (standard of care) to achieve hemostasis after endovascular procedures requiring access within a severely diseased CFA.
This study will be a retrospective single center review of 200 patients undergoing endovascular procedures utilizing vascular access within a severely diseased CFA between 2018 and 2020 at Yale New Haven Hospital. A random selection of patients undergoing hemostasis with manual compression (n = 100) and VASCADE vascular closure system (n = 100) will be conducted. The two groups will then be statistically compared with respect to 48-hour and 30-day safety and efficacy outcomes.
Study Type
Study Type
Enrollment (Actual)
Enrollment
Contacts and Locations
Study Locations
-
-
Connecticut
-
New Haven, Connecticut, United States, 06519
- Yale University
-
-
Participation Criteria
Eligibility Criteria
Eligibility Criteria
Ages Eligible for Study
Accepts Healthy Volunteers
Genders Eligible for Study
Sampling Method
Study Population
Description
Inclusion Criteria:
- 5, 6 or 7 Fr access within the CFA
- ACT < 300 seconds
- Age 18 - 90 years old
- Severe common femoral arterial disease Percent stenosis > 50, which will be core-lab adjudicated
Exclusion Criteria:
- Ipsilateral CFA access within 30 days preceding or subsequent to the index case
- Prior ipsilateral closure device use, other than VASCADE
- High bleeding risk ACT > 300 or > 250 with IIb/IIIa inhibitor Plt < 50K INR > 1.7 on the day of procedure Inherent coagulopathy NOAC, warfarin, or lovenox administered within 24 hours of the procedure
- Suspected intraluminal thrombus, dissection, pseudoaneurysm, hematoma, or AV Fistula
Study Plan
How is the study designed?
Design Details
Number of groups / cohorts
Cohorts and Interventions
Group / CohortGroup / Cohort |
|---|
|
manual compression cohort
Manual compression cohort: Patients who underwent coronary or peripheral angiograms via CFA access with moderate to severe stenosis were hemostasis was achieved via manual compression
|
|
VASCADE cohort
VASCADE cohort: Patients who underwent coronary or peripheral angiograms via CFA access with moderate to severe stenosis were hemostasis was achieved via VASCADE device closure
|
What is the study measuring?
Primary Outcome Measures
Primary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Adequate hemostasis - (efficacy)
Time Frame: within an hour immediately after procedure
|
No evidence of bleeding after device use
|
within an hour immediately after procedure
|
|
No complications after procedure - (safety)
Time Frame: early (48 hours)
|
Early complications rates: bleeding, thrombosis, pseudoaneurysm, arterio-venous fistula, access site infection, mortality
|
early (48 hours)
|
|
No complications after procedure - (safety)
Time Frame: late (30-day)
|
Late complications rates: bleeding, thrombosis, pseudoaneurysm, arterio-venous fistula, access site infection, mortality
|
late (30-day)
|
Collaborators and Investigators
Sponsor
Sponsor
Investigators
Investigators
- Principal Investigator: Carlos Mena-Hurtado, MD, Yale University
- Study Director: Kim Smolderen, Yale University
Publications and helpful links
General Publications
- Bangalore S, Bhatt DL. Femoral arterial access and closure. Circulation. 2011 Aug 2;124(5):e147-56. doi: 10.1161/CIRCULATIONAHA.111.032235. No abstract available.
- Noori VJ, Eldrup-Jorgensen J. A systematic review of vascular closure devices for femoral artery puncture sites. J Vasc Surg. 2018 Sep;68(3):887-899. doi: 10.1016/j.jvs.2018.05.019. Epub 2018 Jun 29.
- Arora N, Matheny ME, Sepke C, Resnic FS. A propensity analysis of the risk of vascular complications after cardiac catheterization procedures with the use of vascular closure devices. Am Heart J. 2007 Apr;153(4):606-11. doi: 10.1016/j.ahj.2006.12.014.
Study record dates
Study Major Dates
Study Start (Actual)
Study Start
Primary Completion (Actual)
Primary Completion
Study Completion (Actual)
Study Completion
Study Registration Dates
First Submitted
First Submitted
First Submitted That Met QC Criteria
First Submitted That Met QC Criteria
First Posted (Actual)
First Posted
Study Record Updates
Last Update Posted (Actual)
Last Update Posted
Last Update Submitted That Met QC Criteria
Last Update Submitted That Met QC Criteria
Last Verified
Last Verified
More Information
Terms related to this study
Other Study ID Numbers
Other Study ID Numbers
- 2000028947
Plan for Individual participant data (IPD)
Plan to Share Individual Participant Data (IPD)?
Drug and device information, study documents
Studies a U.S. FDA-regulated drug product
Studies a U.S. FDA-regulated device product
This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.