Validation of a Novel Non-invasive Continuous Blood Pressure Monitor in Children Ages 2- 17 Years-old
Study Overview
Status
Status
Conditions
Conditions
Intervention / Treatment
Intervention / Treatment
Study Type
Study Type
Enrollment (Actual)
Enrollment
Phase
Phase
- Not Applicable
Contacts and Locations
Study Contact
Study Contact
- Name: Karen Boretsky, MD
- Phone Number: 617-355-7737
- Email: karen.boretsky@childrens.harvard.edu
Study Locations
-
-
Massachusetts
-
Boston, Massachusetts, United States, 02115
- Boston Children's Hopsital
-
-
Participation Criteria
Eligibility Criteria
Eligibility Criteria
Ages Eligible for Study
Accepts Healthy Volunteers
Description
Inclusion Criteria:
- Plan to receive an invasive arterial blood pressure monitor as part of their anesthesia care plan at the BCH Longwood campus
Exclusion Criteria:
- Patients with vascular or congenital heart disease known to affect large and small arteries
- Patients who declined to participate.
Study Plan
How is the study designed?
Design Details
- Primary Purpose: Other
- Allocation: N/A
- Interventional Model: Single Group Assignment
- Masking: None (Open Label)
Number of Arms
Arms and Interventions
Participant Group / ArmParticipant Group / Arm |
Intervention / TreatmentIntervention / Treatment |
|---|---|
|
Other: All Enrolled Patients
Patients will wear the Caretaker Pulse Decomposition Analysis (PDA) Device, which will record the patient's blood pressure.
|
Non-invasive blood pressure monitoring
|
What is the study measuring?
Primary Outcome Measures
Primary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Blood Pressure Comparison (Systolic)
Time Frame: One hour during procedure
|
The accuracy of blood pressure measurements (systolic) taken from the non-invasive blood pressure device will be compared to measurements taken from the patient's indwelling arterial line, which will be place as part of standard of care.
|
One hour during procedure
|
|
Blood Pressure Comparison (Diastolic)
Time Frame: One hour during procedure
|
The accuracy of blood pressure measurements (diastolic) taken from the non-invasive blood pressure device will be compared to measurements taken from the patient's indwelling arterial line, which will be place as part of standard of care.
|
One hour during procedure
|
|
Blood Pressure Comparison (Mean)
Time Frame: One hour during procedure
|
The accuracy of blood pressure measurements (mean) taken from the non-invasive blood pressure device will be compared to measurements taken from the patient's indwelling arterial line, which will be place as part of standard of care.
|
One hour during procedure
|
Collaborators and Investigators
Sponsor
Sponsor
Collaborators
Collaborators
Investigators
Investigators
- Principal Investigator: Karen Boretsky, MD, Boston Children's Hospital
Publications and helpful links
General Publications
- Gratz I, Deal E, Spitz F, Baruch M, Allen IE, Seaman JE, Pukenas E, Jean S. Continuous Non-invasive finger cuff CareTaker(R) comparable to invasive intra-arterial pressure in patients undergoing major intra-abdominal surgery. BMC Anesthesiol. 2017 Mar 21;17(1):48. doi: 10.1186/s12871-017-0337-z.
- Scheer B, Perel A, Pfeiffer UJ. Clinical review: complications and risk factors of peripheral arterial catheters used for haemodynamic monitoring in anaesthesia and intensive care medicine. Crit Care. 2002 Jun;6(3):199-204. doi: 10.1186/cc1489. Epub 2002 Apr 18.
- Baruch MC, Kalantari K, Gerdt DW, Adkins CM. Validation of the pulse decomposition analysis algorithm using central arterial blood pressure. Biomed Eng Online. 2014 Jul 8;13:96. doi: 10.1186/1475-925X-13-96.
- Phillips AA, Burr J, Cote AT, Foulds HJ, Charlesworth S, Bredin SS, Warburton DE. Comparing the Finapres and Caretaker systems for measuring pulse transit time before and after exercise. Int J Sports Med. 2012 Feb;33(2):130-6. doi: 10.1055/s-0031-1291185. Epub 2011 Nov 17.
- The Handbook of Cuffless Blood Pressure Monitoring. Edited by J Sola, Delgado-Gonzalo R, 2019 Springer Nature Swirtzerland AG 2019.
- Heeney ND, Habib F, Brar GK, Krahn G, Campbell DA, Sanatani S, Claydon VE. Validation of finger blood pressure monitoring in children. Blood Press Monit. 2019 Jun;24(3):137-145. doi: 10.1097/MBP.0000000000000374.
- Epstein S, Willemet M, Chowienczyk PJ, Alastruey J. Reducing the number of parameters in 1D arterial blood flow modeling: less is more for patient-specific simulations. Am J Physiol Heart Circ Physiol. 2015 Jul 1;309(1):H222-34. doi: 10.1152/ajpheart.00857.2014. Epub 2015 Apr 17.
- Boretsky KR, Nasr VG, Atkinson D, Baruch M. Comparison of continuous non-invasive blood pressure measurement using Vitalstream to invasive Intraarterial pressure in pediatric surgery. J Clin Anesth. 2025 Mar;102:111763. doi: 10.1016/j.jclinane.2025.111763. Epub 2025 Jan 23.
Study record dates
Study Major Dates
Study Start (Actual)
Study Start
Primary Completion (Actual)
Primary Completion
Study Completion (Actual)
Study Completion
Study Registration Dates
First Submitted
First Submitted
First Submitted That Met QC Criteria
First Submitted That Met QC Criteria
First Posted (Actual)
First Posted
Study Record Updates
Last Update Posted (Actual)
Last Update Posted
Last Update Submitted That Met QC Criteria
Last Update Submitted That Met QC Criteria
Last Verified
Last Verified
More Information
Terms related to this study
Other Study ID Numbers
Other Study ID Numbers
- IRB-P00037138
Plan for Individual participant data (IPD)
Plan to Share Individual Participant Data (IPD)?
Drug and device information, study documents
Studies a U.S. FDA-regulated drug product
Studies a U.S. FDA-regulated device product
product manufactured in and exported from the U.S.
This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.