A 3D Tablet Sensor Approach to the Measurement of a Lymphedema (LO3D)
A 3D Tablet Sensor Approach to the Measurement of an Upper and Lower Limb Volume in the Monitoring of a Lymphedema
Study Overview
Status
Status
Conditions
Conditions
Intervention / Treatment
Intervention / Treatment
Study Type
Study Type
Enrollment (Actual)
Enrollment
Phase
Phase
- Not Applicable
Contacts and Locations
Study Contact
Study Contact
- Name: Simon GESTIN
- Phone Number: 02 98 34 75 45
- Email: simon.gestin@chu-brest.fr
Study Contact Backup
- Name: Wit HAERTLE
- Phone Number: 06 82 50 86 14
- Email: dr@haertle.fr
Study Locations
-
-
-
Brest, France, 29200
- CHU de Brest
-
Pont-l'Abbé, France
- CH Pont l'Abbé
-
-
Participation Criteria
Eligibility Criteria
Eligibility Criteria
Ages Eligible for Study
Accepts Healthy Volunteers
Description
Inclusion Criteria:
- Unilateral lymphedema
Exclusion Criteria:
- Minor patient,
- Bilateral lymphedema,
- Trophic disorders: Acute or recent skin infection (<1 month after the end of antibiotic therapy), unhealed wounds.
- Predictable difficulties in carrying out the measurements due to the patient's physical limitations (maintenance of orthostatic or sitting position <5 minutes)
- Single or bilateral edema with a different etiology than lymphedema.
Study Plan
How is the study designed?
Design Details
- Primary Purpose: Health Services Research
- Allocation: Non-Randomized
- Interventional Model: Parallel Assignment
- Masking: Double
Number of Arms
Arms and Interventions
Participant Group / ArmParticipant Group / Arm |
Intervention / TreatmentIntervention / Treatment |
|---|---|
|
Active Comparator: Lower Limb Lymphedema
Patients suffering from unilateral lower-limb lymphedema will receive volume measurements of their limb three times, once with the water displacement method, twice with the 3D sensor method
|
The examination will take place in several stages and by two operators.
Initially, the patient will strip the limb concerned (leg or arm).
Once the member is in the water column of the volumeter, a delimitation of the submerged area of the member will be carried out using a marking (black dermographic marker).
Indeed, the level of acquisition in 3D is determined relative to the height of the water line marked on the skin with a black felt, this felt is usually used for venous mapping and is well tolerated The first operator will carry out two measurements one after the other with a change of water previously stabilized at room temperature.
The 3D volumetric acquisition is done with the sensor (CE marking) attached to the touch pad and does not require invasive or cutaneous contact with the patient (minimum acquisition distance of 40 cm).
The operator triggers the acquisition via a button in an application installed on the tablet and physically turns around the patient to carry out the acquisition of the affected member.
At the end of the acquisition, the operator presses a stop button and chooses whether or not to calculate the volume using another button depending on the quality of the acquisition.
|
|
Active Comparator: Upper Limb Lymphedema
Patients suffering from unilateral upper-limb lymphedema will receive volume measurements of their limb three times, once with the water displacement method, twice with the 3D sensor method
|
The examination will take place in several stages and by two operators.
Initially, the patient will strip the limb concerned (leg or arm).
Once the member is in the water column of the volumeter, a delimitation of the submerged area of the member will be carried out using a marking (black dermographic marker).
Indeed, the level of acquisition in 3D is determined relative to the height of the water line marked on the skin with a black felt, this felt is usually used for venous mapping and is well tolerated The first operator will carry out two measurements one after the other with a change of water previously stabilized at room temperature.
The 3D volumetric acquisition is done with the sensor (CE marking) attached to the touch pad and does not require invasive or cutaneous contact with the patient (minimum acquisition distance of 40 cm).
The operator triggers the acquisition via a button in an application installed on the tablet and physically turns around the patient to carry out the acquisition of the affected member.
At the end of the acquisition, the operator presses a stop button and chooses whether or not to calculate the volume using another button depending on the quality of the acquisition.
|
What is the study measuring?
Primary Outcome Measures
Primary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Accuracy of a 3D sensor for lymphedema volumetry
Time Frame: One hour
|
Intra-class correlation coefficient (ICC) Mean bias and limits of agreement (LOA) derived from the Blant-Altman diagram Mean bias and limits of agreement (LOA) derived from the Blant-Altman diagram
|
One hour
|
Secondary Outcome Measures
Secondary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Reproducibility of measurements made with a 3D sensor for lymphedema volumetry
Time Frame: One hour
|
Intra-class correlation coefficient (ICC)
|
One hour
|
Collaborators and Investigators
Sponsor
Sponsor
Study record dates
Study Major Dates
Study Start (Actual)
Study Start
Primary Completion (Actual)
Primary Completion
Study Completion (Actual)
Study Completion
Study Registration Dates
First Submitted
First Submitted
First Submitted That Met QC Criteria
First Submitted That Met QC Criteria
First Posted (Actual)
First Posted
Study Record Updates
Last Update Posted (Actual)
Last Update Posted
Last Update Submitted That Met QC Criteria
Last Update Submitted That Met QC Criteria
Last Verified
Last Verified
More Information
Terms related to this study
Keywords
Additional Relevant MeSH Terms
Other Study ID Numbers
Other Study ID Numbers
- 29BRC20.0049
Drug and device information, study documents
Studies a U.S. FDA-regulated drug product
Studies a U.S. FDA-regulated device product
This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.