BCI-Based Control for Ankle Exoskeleton T-FLEX: Comparison of Visual and Haptic Feedback With Stroke Survivors
Study Overview
Status
Status
Conditions
Conditions
Intervention / Treatment
Intervention / Treatment
Detailed Description
Study Type
Study Type
Enrollment (Actual)
Enrollment
Phase
Phase
- Not Applicable
Contacts and Locations
Study Locations
-
-
XII Región
-
Punta Arenas, XII Región, Chile, 6211525
- Corporación de Rehabilitación Club de Leones Cruz del Sur
-
-
Participation Criteria
Eligibility Criteria
Eligibility Criteria
Ages Eligible for Study
Accepts Healthy Volunteers
Genders Eligible for Study
Description
Inclusion Criteria:
- Unilateral lower extremity paresis
- Hemorrhagic or ischemic stroke
- A minimum of six months after the acute infarction/onset of the disease
- Full passive range of motion in lower extremity or at least at neutral position
- Be able to stand freely
- Be able to walk with or without aid for at least 20 meters in less than 2 minutes
Exclusion Criteria:
- Peripheral nervous system pathology
- Epilepsy
- Weight over 100 kg
- No cognitive ability to follow the study instructions
- Pregnancy
- Use of implanted devices
- Instable lower extremity joints or fixed contracture
Study Plan
How is the study designed?
Design Details
- Primary Purpose: Treatment
- Allocation: N/A
- Interventional Model: Single Group Assignment
- Masking: None (Open Label)
Number of Arms
Arms and Interventions
Participant Group / ArmParticipant Group / Arm |
Intervention / TreatmentIntervention / Treatment |
|---|---|
|
Experimental: Implementation of a BCI system integrated to the T-FLEX lower-limb exoskeleton in post-stroke
The participants will carry out tests for the evaluation of the functionality of the BCI system integrated to the T-FLEX device.
The test consists of 1 session that includes four conditional experiments.
Real Movement, Continuous Stationary Therapy, Motor Imagery Detection with Visual Stimulation, and Motor Imagery Detection with Tactile Stimulation.
|
The participants will carry out 4 tasks with a BCI system integrated to the T-FLEX device.
The task consists of 1 session that includes 4 conditional experiments: Active ankle movement, passive ankle movement, Motor Imagery Detection with Visual cue, and Motor Imagery Detection with Tactile Stimulation and visual cue.
|
What is the study measuring?
Primary Outcome Measures
Primary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Response time
Time Frame: Baseline
|
The response time for each task will be automatically measured by a Visual Studio Code Software during the use of the Brain-Computer Interface. This variable will consider the response time of a specific command, since the subject receives the stimulation until the software detects the EEG Signal. The measure unit is milliseconds |
Baseline
|
|
EEG signals from primary motor cortex
Time Frame: Baseline
|
continuous signals will be acquired from the primary motor cortex of lower limbs (FcZ, C2, Cz, C1, Cpz) according to the 10-20 International EEG System.
Power spectral density in the frequency band of motor imagery (8-32Hz) will be obtained by OpenVibe Software and Matlab.
The measure unit is Decibels per Hertz(dB/Hz).
|
Baseline
|
Secondary Outcome Measures
Secondary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Patient satisfaction with device: Quebec User Evaluation of Satisfaction with Assistive Technology
Time Frame: Baseline
|
Measured with QUEST scale.
The Quebec User Evaluation of Satisfaction with Assistive Technology (QUEST 2.0) is a 12-item outcome measure that assesses user satisfaction with two components, Device and Services.
Scores of 1 indicate dissatisfaction and scores of 5 indicate high satisfaction
|
Baseline
|
Collaborators and Investigators
Sponsor
Sponsor
Collaborators
Collaborators
Investigators
Investigators
- Study Chair: Asterio H Andrade, PhD, Rehabilitation Center Club de Leones Cruz del Sur
Publications and helpful links
General Publications
- Needham DM, Truong AD, Fan E. Technology to enhance physical rehabilitation of critically ill patients. Crit Care Med. 2009 Oct;37(10 Suppl):S436-41. doi: 10.1097/CCM.0b013e3181b6fa29.
- Verma R, Arya KN, Sharma P, Garg RK. Understanding gait control in post-stroke: implications for management. J Bodyw Mov Ther. 2012 Jan;16(1):14-21. doi: 10.1016/j.jbmt.2010.12.005. Epub 2010 Dec 30.
- Chen G, Chan CK, Guo Z, Yu H. A review of lower extremity assistive robotic exoskeletons in rehabilitation therapy. Crit Rev Biomed Eng. 2013;41(4-5):343-63. doi: 10.1615/critrevbiomedeng.2014010453.
- Gomez-Vargas D, Ballen-Moreno F, Barria P, Aguilar R, Azorin JM, Munera M, Cifuentes CA. The Actuation System of the Ankle Exoskeleton T-FLEX: First Use Experimental Validation in People with Stroke. Brain Sci. 2021 Mar 24;11(4):412. doi: 10.3390/brainsci11040412.
- He Y, Eguren D, Azorin JM, Grossman RG, Luu TP, Contreras-Vidal JL. Brain-machine interfaces for controlling lower-limb powered robotic systems. J Neural Eng. 2018 Apr;15(2):021004. doi: 10.1088/1741-2552/aaa8c0.
- Ortiz M, Ianez E, Contreras-Vidal JL, Azorin JM. Analysis of the EEG Rhythms Based on the Empirical Mode Decomposition During Motor Imagery When Using a Lower-Limb Exoskeleton. A Case Study. Front Neurorobot. 2020 Aug 27;14:48. doi: 10.3389/fnbot.2020.00048. eCollection 2020.
- Ma T, Li H, Deng L, Yang H, Lv X, Li P, Li F, Zhang R, Liu T, Yao D, Xu P. The hybrid BCI system for movement control by combining motor imagery and moving onset visual evoked potential. J Neural Eng. 2017 Apr;14(2):026015. doi: 10.1088/1741-2552/aa5d5f. Epub 2017 Feb 1.
- Thomas E, Dyson M, Clerc M. An analysis of performance evaluation for motor-imagery based BCI. J Neural Eng. 2013 Jun;10(3):031001. doi: 10.1088/1741-2560/10/3/031001. Epub 2013 May 3.
- Ortiz M, Ferrero L, Ianez E, Azorin JM, Contreras-Vidal JL. Sensory Integration in Human Movement: A New Brain-Machine Interface Based on Gamma Band and Attention Level for Controlling a Lower-Limb Exoskeleton. Front Bioeng Biotechnol. 2020 Sep 3;8:735. doi: 10.3389/fbioe.2020.00735. eCollection 2020.
Study record dates
Study Major Dates
Study Start (Actual)
Study Start
Primary Completion (Actual)
Primary Completion
Study Completion (Actual)
Study Completion
Study Registration Dates
First Submitted
First Submitted
First Submitted That Met QC Criteria
First Submitted That Met QC Criteria
First Posted (Actual)
First Posted
Study Record Updates
Last Update Posted (Actual)
Last Update Posted
Last Update Submitted That Met QC Criteria
Last Update Submitted That Met QC Criteria
Last Verified
Last Verified
More Information
Terms related to this study
Keywords
Additional Relevant MeSH Terms
Other Study ID Numbers
Other Study ID Numbers
- CorporacionRCLCS0005
Plan for Individual participant data (IPD)
Plan to Share Individual Participant Data (IPD)?
Drug and device information, study documents
Studies a U.S. FDA-regulated drug product
Studies a U.S. FDA-regulated device product
This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.
Clinical Trials on Stroke
-
NCT07208422RecruitingStroke | Stroke Hemorrhagic | Stroke Ischemic | Hemiparesis After Stroke
-
NCT07224178RecruitingHemorrhagic Stroke | Embolic Stroke of Undetermined Source | Ischemic Stroke, Cryptogenic | Recurrent Ischemic Stroke | Ischemic Stroke, Embolic
-
NCT07433972Not yet recruitingIschemic Stroke | Hemorrhagic Stroke | Subacute Stroke | Chronic Stroke Survivors
-
NCT07236216RecruitingIschemic Stroke | Hemorrhagic Stroke | Subacute Stroke | Chronic Stroke Patient
-
NCT04956185RecruitingStroke | Stroke, Ischemic | Stroke, Acute | Stroke Sequelae | Stroke Hemorrhagic
-
NCT05046106Not yet recruitingStroke | Stroke, Ischemic | Stroke Sequelae | Stroke, Cardiovascular | Strokes Thrombotic | Stroke, Embolic | Stroke, Cryptogenic
-
NCT07353203CompletedChronic Stroke | Subacute Stroke | Exoskeleton
-
NCT07199322Not yet recruitingStroke | Stroke Hemorrhagic | Upper Limb Rehabilitation | Stroke Ischemic
-
NCT06127602RecruitingStroke, Ischemic | Stroke Hemorrhagic | Stroke, Cerebrovascular
-
NCT05815368RecruitingStroke | Stroke, Ischemic | Stroke Sequelae | Stroke Hemorrhagic
Clinical Trials on Implementation of a BCI system integrated to the T-FLEX lower-limb exoskeleton in post-stroke patients.
-
NCT02138708WithdrawnPulmonary Arterial Hypertension With Congenital Cardiac Shunt