Remote Evaluation of the Naída CI M90 (Marvel) Sound Processor
Within-subject comparison. Remotely Evaluating latest Advanced Bionics Marvel Sound Processor for cochlear implants, from two adult groups.
Study Overview
Status
Status
Conditions
Conditions
Detailed Description
Within-subject comparison, standard of care CE marked Advanced Bionics device. Remote Evaluation of new CI Naida M sound processor through speech understanding in quiet and noise using standard clinical tests, subjective feedback on sound quality for a set of listening situations reflecting everyday use and a ease of use questionnaire. Two adult groups, one CI users and the other bimodal users. All tests completed remotely.
Study Type
Study Type
Enrollment (Actual)
Enrollment
Contacts and Locations
Study Locations
-
-
-
Cambridge, United Kingdom, CB2 OQQ
- Cambridge Biomedical Campus, Addenbrookes Hospital
-
-
Participation Criteria
Eligibility Criteria
Eligibility Criteria
Ages Eligible for Study
Accepts Healthy Volunteers
Genders Eligible for Study
Sampling Method
Study Population
Adult Advanced Bionics cochlear implant users due for a sound processor upgrade in line with normal standard of care. Able to access the internet and undertake tests remotely.
Description
Inclusion Criteria:
-
CI users with a CI, HiRes90K (Advantage) or HiRes Ultra cochlear implant system
-
Unilaterally implanted recipients using only a Naída Q sound processor
-
Bimodal users: additionally using hearing aid on their contralateral ear
- Minimum of 18 years of age
- Minimum of five years' experience with their Naída Q sound processor
- Minimum of six months experience with their contralateral hearing aid (if applicable)
- Ability to give feedback on sound quality
- Speech intelligibility with the BKB sentence test in noise at a +10 dB SNR > 10% as obtained during previous visits in the clinical routine or BKB >50% in quiet conditions if noise has previously not been tested
- Fluent in English language
Exclusion Criteria:
- Difficulties additional to hearing impairment that would interfere with the study procedures
- Concurrent participation in any other clinical hearing study
- Not due to have their sound processor upgraded in line with normal clinical procedures
Study Plan
How is the study designed?
Design Details
- Observational Models: COHORT
- Time Perspectives: PROSPECTIVE
What is the study measuring?
Primary Outcome Measures
Primary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Evaluate difference in speech perception in noise with Naida M (Marvel) and Naida Q hearing devices
Time Frame: 12 months
|
Understanding speech in presence of completing noise and quiet testing remotely through use of Gorilla software. This will be done through a percentage score calculated within the Gorilla software. |
12 months
|
Secondary Outcome Measures
Secondary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Differences in sound clarity and comfort with Naida M (Marvel) device when listening to speech
Time Frame: 12 months
|
Assessment in quiet, background, speech babble, household noises, traffic noise, cafeteria noise and louder alarm signals.This will be done through a measurement of specific questionnaires. |
12 months
|
Collaborators and Investigators
Sponsor
Sponsor
Study record dates
Study Major Dates
Study Start (Actual)
Study Start
Primary Completion (Actual)
Primary Completion
Study Completion (Actual)
Study Completion
Study Registration Dates
First Submitted
First Submitted
First Submitted That Met QC Criteria
First Submitted That Met QC Criteria
First Posted (Actual)
First Posted
Study Record Updates
Last Update Posted (Actual)
Last Update Posted
Last Update Submitted That Met QC Criteria
Last Update Submitted That Met QC Criteria
Last Verified
Last Verified
More Information
Terms related to this study
Additional Relevant MeSH Terms
Other Study ID Numbers
Other Study ID Numbers
- 292396
Plan for Individual participant data (IPD)
Plan to Share Individual Participant Data (IPD)?
Drug and device information, study documents
Studies a U.S. FDA-regulated drug product
Studies a U.S. FDA-regulated device product
This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.