Reproducibility and Accuracy of a Portable System for Early Detection of Cardiac Dysfunction in Childhood Cancer Survivors
Assessment of the Reproducibility and Accuracy of a Portable System for Early Detection of Cardiac Dysfunction in Childhood Cancer Survivors
Study Overview
Status
Status
Conditions
Conditions
Intervention / Treatment
Intervention / Treatment
Detailed Description
Primary Objective(s)
Validate the accuracy of ejection fraction, as measured using a tonometry-based system (SphygmoCor® Xcel), in the clinic setting, and determine the reproducibility (Oscar 2™) at home.
Secondary Objective(s)
Determine the cost-effectiveness of tonometry-based screening in the clinic setting and at home.
Study Type
Study Type
Enrollment (Actual)
Enrollment
Phase
Phase
- Not Applicable
Contacts and Locations
Study Locations
-
-
California
-
Duarte, California, United States, 91010
- City of Hope Medical Center
-
-
Participation Criteria
Eligibility Criteria
Eligibility Criteria
Ages Eligible for Study
- Child
- Adult
- Older Adult
Accepts Healthy Volunteers
Description
Inclusion Criteria:
- Previously enrolled in IRB# 14154.
- Able to understand and sign the study specific informed consent form (ICF).
Exclusion Criteria:
- Participants cannot be actively receiving cancer-directed therapy.
- Standard exclusion criteria for CMR imaging will be incorporated, and these include: implanted pacemaker or defibrillator, insulin pump, cochlear implant, central nervous system aneurismal clips, implanted neural stimulator, ocular foreign body (metal), other implanted medical devices (e.g.: drug infusion ports).
Study Plan
How is the study designed?
Design Details
- Primary Purpose: Screening
- Allocation: N/A
- Interventional Model: Single Group Assignment
- Masking: None (Open Label)
Number of Arms
Arms and Interventions
Participant Group / ArmParticipant Group / Arm |
Intervention / TreatmentIntervention / Treatment |
|---|---|
|
Experimental: Screening (echo, CMR, Tonometry-based system)
Patients undergo a one time assessment of cardiac function by echo, CMR, and the Tonometry-based system system in the clinic over 4-6 hours, and will be asked to perform their home-based measurements within 1-5 days of the clinical assessment, allowing us to directly compare measurements obtained by survivors to those by research personnel.
Patients also complete questionnaires at baseline.
|
Undergo assessment via echo
Other Names:
Ancillary Studies
Undergo assessment via CMR
SphygmoCor® Xcel Oscar 2™ Ambulatory Blood Pressure Monitor
|
What is the study measuring?
Primary Outcome Measures
Primary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Accuracy of ejection fraction (EF) in the clinic setting, and determine its reproducibility at home.
Time Frame: Up to 2 years
|
Validate the accuracy of ejection fraction, as measured using a tonometry-based system (SphygmoCor® Xcel), in the clinic setting, and determine the reproducibility (Oscar 2™) at home.
|
Up to 2 years
|
Secondary Outcome Measures
Secondary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Cost-effectiveness of tonometry-based screening in the clinic setting and at home.
Time Frame: Up to 2 years
|
Will apply the sensitivity and specificity of echo, CMR, and the Oscar 2™ ABPM system (clinic, home-based) to compare the number of asymptomatic cardiac dysfunction cases identified via each method.
Screening costs for echo and CMR, including costs of clinical services, will be obtained from the 2020 Centers for Medicare & Medicaid Services (CMS).
|
Up to 2 years
|
Collaborators and Investigators
Sponsor
Sponsor
Collaborators
Collaborators
Investigators
Investigators
- Principal Investigator: Saro H Armenian, City of Hope Medical Center
Study record dates
Study Major Dates
Study Start (Actual)
Study Start
Primary Completion (Estimated)
Primary Completion
Study Completion (Estimated)
Study Completion
Study Registration Dates
First Submitted
First Submitted
First Submitted That Met QC Criteria
First Submitted That Met QC Criteria
First Posted (Actual)
First Posted
Study Record Updates
Last Update Posted (Estimated)
Last Update Posted
Last Update Submitted That Met QC Criteria
Last Update Submitted That Met QC Criteria
Last Verified
Last Verified
More Information
Terms related to this study
Additional Relevant MeSH Terms
Other Study ID Numbers
Other Study ID Numbers
- 21466 (City of Hope Medical Center)
- P30CA033572 (U.S. NIH Grant/Contract)
- NCI-2021-11335 (Registry Identifier: CTRP (Clinical Trial Reporting Program))
- R21CA261797 (U.S. NIH Grant/Contract)
Drug and device information, study documents
Studies a U.S. FDA-regulated drug product
Studies a U.S. FDA-regulated device product
product manufactured in and exported from the U.S.
This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.